KILLARK, 킬락 조명부문 2014 미니카탈로그 소개자료(신제품출시)

 

안녕하세요 TIATIP입니다.

 

오늘은 KILLARK(킬락)의 조명부문가운데 2014년 새롭게 론칭되는 LED타입의 조명자료로서 2014 미니카탈로그를 소개드립니다. 금년 기대되는 신제품의 출시가 이어질 것이 예고되고 있는 가운데, 종합카탈로그가 준비되는 시점에서 소식전하도록 하게겠습니다.

 

Expanding Range of Harsh & Hazardous LED Luminaires and Sytstems

KILLARK LED MINI CATALOG

 

 

From basic Utility Luminaires to complex Egress Lighting Systems, Killark is a major provider of LED labor and energy saving products for harsh and hazardous locations.


Market demand for this long life, clean white light is growing exponentially. Killark is there with a range of products for Class I, Div. 1 & 2, Zones 1 and 2, plus Class II applications.


Killark also satisfies the need for wet and corrosive environments with NEMA 4X ratings.

 

1. KILLARK LED VSL Series, "Utility Light"

 

 

Introduction

Killark ‘VSL’ Series LED fixtures are designed for installations where moisture, dirt, dust, corrosion and vibration may be present, or NEMA 3 and 4 areas where wind, water, snow or high ambients can be expected. VSL’s are sized to replace “Utility” type fixtures (incandescent or CFL’s) in hallways, closets, elevator pits, docks, stairwells, access tunnels, and mechanical rooms. These
fixtures can be used in locations made hazardous by the presence of flammable vapors or gases or combustible dusts as defined by the NEC. Typical applications include manufacturing plants, and certain chemical and petrochemical processing facilities, sewage treatment plants, off-shore and
dockside installations, and garage areas.

 

 

 

LED Luminaire Features and Standards
• Compact in Size with Traditional Industrial Appearance and Suitability
• Wide variety of optics including glass globes (clear and tempered, color) plus polycarbonate globes in clear and colors
• Optional Mounting arrangements including Pendant, Wall, Ceiling, Stanchion and Adapters
• Fixtures available unit packed, order option CP
• VSL LED Housings can be retrofitted to existing V Series splice boxes; upgrade from CFL or incandescent
• Energy Savings - less than 13 Watts of Power; less than 16 Watts for VSL1630. Replaces 75W or higher incandescent
• Long Life - 60,500+ maintenance-free hours to 70% initial lumens
• Crisp White Light for Excellent Color Rendering-Chromaticity 5000K (CCT); 70 CRI
• Integral driver - maintains fixture’s compact profile to fit in existing spaces
• Ambient suitability -40°C to 55°C

• Instant on - including after power interruption
• “World Voltage” 120-277VAC 50/60Hz
• Solder-LESS LED Board Connections – Vibration Resistant
• LM80-08* Measurement of lumen maintenance for LED light sources
• LM79-08* Certified “Absolute” Photometry, including Chromaticity Color for Solid State Lighting
• TM-21* method to project long term lumen maintenance
• L70 Values - Industry Nomenclature for Hours of use to 70% of Initial Lumens

 

Materials
• Body, splice box and guards are corrosion resistant copper-free aluminum alloy
• Baked powder epoxy/polyester finish, electrostatically applied for complete, uniform corrosion protection
• Reflectors - Polypropylene for pendant or ceiling applications
• Heavy-duty silicone gasketing for NEMA 4 requirements 

 

 

2. KILLARK LED DVL Series, "Class II Utility Light"

 

 

 

Introduction

Killark ‘DVL’ Series LED fixtures are designed for hazardous locations where suspended metal, carbon (such as coal) and grain dusts create explosive or ignitable mixture with the air.

 

LED Luminaire Features and Standards
• Compact in Size with Traditional Industrial Appearance and Suitability
• DVL LED Housings can be retrofitted to existing DV Series splice boxes; upgrade from incandescent housing 100 Series components
• Long Life - 60,500+ maintenance-free hours to 70% initial lumens
• Crisp White Light for Excellent Color Rendering
- Chromaticity 5000K (CCT); 70 CRI
• Integral driver - maintains fixture’s compact profile to fit in existing spaces
• Instant on - including after power interruption
• “World Voltage” 120-277VAC 50/60Hz
• Solder-LESS LED Board Connections – Vibration Resistant

 

Compliances
• UL-8750 for LED lighting
• UL 1598 standard for luminaires
• UL-844 Standard for lighting fixtures for hazardous locations, Class I, Division 2; Class II, Division 2; Class III, Division 2
• CSA C22.2 no. 137-M1981 electric luminaries for use in hazardous locations

 

Materials, Weights
• Body and splice box are corrosion resistant copper-free aluminum alloy. Steel guard.
• Baked powder epoxy/polyester finish, electrostatically applied for complete, uniform corrosion protection
• Typical Weights (lbs.) with Standard Globe and Guard - DVL Series Pendant 7.7, Ceiling 7.7 and Wall 8.5

 

 

3. KILLARK LED MBL Series, "Compact Size"

 

 

 

Applications
CERTILITE ® MBL LED fixtures are designed for installations where moisture, dirt, dust, corrosion and vibration may be present, or NEMA 3 and 4X areas where wind, water, snow or high ambients can be expected. They can be used
in locations made hazardous by the presence of flammable vapors or gases or combustible dusts as defined by the NEC.
Typical applications can low ceiling areas in manufacturing plants, and certain chemical and petrochemical processing facilities, sewage treatment plants, off-shore and dockside installations, garages and storage facilities.

 

Compliances
• UL-8750 for LED lighting; UL 1598A
• UL Marine type lighting fixtures
UL-844 Standard for lighting fixtures for hazardous locations, Class I, Division 2; Class II, Divisions 1 and 2; Class III
• CSA C22.2 no. 137-M1981 electric luminaries for use in hazardous locations
• Enclosed and gasketed
• NEMA 3, 4X

 

Materials
• Ballast tank, splice box and guards (MBAG, VMAG) corrosion resistant copper-free aluminum alloy
• Baked powder epoxy/polyester finish, electrostatically applied for complete, uniform corrosion protection
• All external hardware - stainless steel
• Reflectors - Polyester reinforced fiberglass

 

LED Luminaire Features and Standards
• Compact in Size with Traditional Industrial Appearance and Suitability
• Wide variety of optics including globes, globes with reflectors, all-glass refractors, and spin-top refractors
• Optional Mounting arrangements including Pendant, Wall, Ceiling, and Stanchion
• MBL LED Housings can be retrofitted to existing MB splice boxes; upgrade from Fluorescent or HID
• Energy Savings - less than 50 Watts of Power; 25 Watts for MBL2230
• Long Life up to 100,000+ maintenance free hours to 70% initial lumens
• Crisp White Light for Excellent Color Rendering - Chromaticity 5000K (CCT); 70 CRI, TM-21
• Ambient suitability -40°C to 40°C (to 55°C for 14W to 22W)

• Instant on - including after power interruption
• “World Voltage” 120-277VAC 50/60Hz
• Solder-LESS LED Board Connections – Vibration Resistant
• Dual Drivers 40, 45, 50W - Redundant Systems (built-in backup), or for additional energy savings half of MBL luminaire can be turned off
• LM80-08* Measurement of lumen maintenance for LED light sources
• LM79-08* Certified “Absolute” Photometry, including Chromaticity Color for Solid State Lighting
• L70 Values - Industry Nomenclature for Hours of use to 70% of Initial Lumens (TM-21+ Cal.)

 

 

4. KILLARK LED VM1L Series, "Reduced Profile"

 

 

 

Applications
CERTILITE®V VM1L LED fixtures are designed for installations where moisture, dirt, dust, corrosion and vibration may be present, or NEMA 3 and 4X areas where wind, water, snow or high ambients can be expected. They can be
used in locations made hazardous by the presence of flammable vapors or gases or combustible dusts as defined by the NEC.
Typical applications include manufacturing plants, and certain chemical and petrochemical processing facilities, sewage treatment plants, off-shore and dockside installations, garages and storage facilities.

Compliances
• UL-8750 for LED lighting
• UL Marine type lighting fixtures (HID models)
UL-844 Standard for lighting fixtures for hazardous locations, Class I, Division 2; Class II, Divisions 1 and 2; Class III
• CSA C22.2 no. 137-M1981 electric luminaries for use in hazardous locations
• Enclosed and gasketed
• NEMA 3, 4X

 

Materials
• Ballast tank, splice box and cast guards corrosion resistant copper-free aluminum alloy
• Baked powder epoxy/polyester finish, electrostatically applied for complete, uniform corrosion protection
• All external hardware - stainless steel
• Reflectors - Polyester reinforced fiberglass

 

LED Luminaire Features and Standards
• Reduced profile with Traditional Industrial Appearance and Suitability
• Wide variety of optics including globes, globes with reflectors, all-glass refractors, and spin-top refractors

• Swing-Barrel Nut patented tank mounting system
• Optional Mounting arrangements including Pendant, Wall, Ceiling, Stanchion and others
• VM1L LED Housings can be retrofitted to existing VM splice boxes; upgrade from HID sources
• Energy Savings - less than 55 Watts of Power
• Long Life - 50,000 - 55,000 maintenance free hours to 70% initial lumens
• Crisp White Light for Excellent Color Rendering - Chromaticity 5000K (CCT); 70 CRI
• Ambient suitability -40°C to 55°C
• Instant on - including after power interruption
• “World Voltage” 120-277VAC 50/60Hz

• Solder-LESS LED Board Connections – Vibration Resistant
• Dual Drivers - Redundant Systems (built-in backup), or for additional energy savings half of VM1L4530 can be turned off
• LM80-08* Measurement of lumen maintenance for LED light sources
• LM79-08* Certified “Absolute” Photometry, including Chromaticity Color for Solid State Lighting
• L70 Values - Industry Nomenclature for Hours of use to 70% of Initial Lumens

 

 

5. KILLARK LED VM2LB, VM2LC, VM4LB and VM4LC Series, "High Wattage"

 

 

 

Applications
CERTALITE® V VM4L LED fixtures are designed for installations where moisture, dirt, dust, corrosion and vibration may be present, or NEMA 3 and 4X areas where wind, water, snow or high ambients can be expected. They can be used in locations made hazardous by the presence of flammable vapors or gases or combustible dusts as defined by the NEC/CEC.
Typical applications include manufacturing plants, food processing, and certain
chemical and petrochemical processing facilities, sewage treatment plants,
off-shore and dockside installations, garages and storage facilities.

 

Compliances
• UL-8750 for LED lighting
• UL-844 Standard for lighting fixtures for hazardous locations, Class I,
Division 2; Class II, Divisions 1 and 2; Class III
• CSA C22.2 no. 137-M1981 electric luminairies for use in hazardous locations
• Enclosed and gasketed
• NEMA 3, 4X
• IP66 & Marine

 

Materials
• Ballast tank, splice box and cast guards corrosion resistant copper-free
aluminum alloy
• Baked powder epoxy/polyester finish, electrostatically applied for complete,
uniform corrosion protection
• All external hardware - stainless steel
• Reflectors - Polyester reinforced fiber glass or aluminum

 

LED Luminaire Features and Standards
• Traditional Industrial Appearance, Suitability, and Photometric Performance

• Wide variety of optics including globes, globes with reflectors, all-glass refractors, spin-top refrac tors and flat lens
• Swing-Barrel Nut patented tank mounting system
• Optional Mounting arrangements including Pendant, Wall, Ceiling,
Stanchion and others
• VM4L LED Housings can be retrofitted to existing VM splice boxes;
upgrade from HID sources
• VM2Lx housing is 1.56” shallower for low ceilings to 65 Watt
• Crisp White Light for Excellent Color Rendering - Chromaticity
5000K (CTT range); approx. 70 CRI
• Energy Savings - less than 130 Watts of Power
• Long Life - 50,000 - 55,000 maintenance free hours to 70% initial lumens
• Ambient suitability -40°C to 55°C

• Instant On - Including after power interruption
• World Voltage 120 - 277VAC 50/60Hz
• Solder-LESS LED Board Connections - Vibration Resistant
• Dual Drivers - Redundant Systems (built-in backup) for most models, or
for additional energy savings half of fixture can be turned off
• LM80-08* Measurement of lumen maintenance for LED light sources
(including TM-21)
• LM79-08* Certified “Absolute” Photometry, including Chromaticity
Color for Solid State Lighting
• L70 Values - Industry Nomenclature for Hours of use to 70% of Initial Lumens
• Two LED internal heat sink styles
- Bulb VM2LB/VM4LB
- Concave VM2LC/VM4LC

 

 

6. KILLARK LED EML Series, "Explosion-Proof"

 

 

Applications
HOSTILELITE® EML LED Series fixtures are designed for installations where moisture, dirt, dust, corrosion and vibration may be present, or NEMA 3 and 4x areas where wind, water, snow or high ambients can be expected. They
can be used in locations made hazardous due to the presence of flammable or explosive gases, vapors and combustible dusts as defined by the NEC.
Applications include classified areas such as paint manufacturing plants, ammunition facilities, oil and gas producing and refining plants,
off-shore and dockside installations, tank farms, pipeline pumping stations and marine loading and fuel transfer terminals.

 

Compliances
• UL-8750 for LED lighting
• UL-844 Electric Lighting Fixtures for use in Hazardous Locations
• UL Marine Type Electric Lighting Fixtures
• CSA C22.2 no. 137-M1981 Electric Luminaires for use in Hazardous Locations
• NEMA 3, 4, 4X, 7CD, 9EFG
 

Materials
• Ballast tank, splice box and guards corrosion resistant copper-free aluminum alloy
• Baked powder epoxy/polyester finish, electorstatically applied for complete, uniform corrosion protection
• All external hardware - Stainless Steel
• Reflectors are aluminum with white finish

 

LED Luminaire Features and Standards
• Compact Explosion-proof with Traditional Industrial Appearance and Suitability
• Fluted or Exclusive Clear Globe; Dome or Angle Reflectors

• Optional Mounting arrangements including Pendant, Wall, Ceiling, and Stanchion
• EML LED Housings can be retrofitted to existing EZ splice boxes; upgrade from Incandescent, Fluorescent or HID
• Energy Savings - less than 55 Watts of Power

• Long Life - 50,000 - 55,000 Maintenance Free Hours to 70% Initial Lumens
• Crisp White Light for Excellent Color Rendering - Chromaticity Avg. 4950K (CCT); 69 CRI
• Ambient suitability -40°C to 55°C
• Instant on - including after power interruption
• “World Voltage” 120-277VAC 50/60Hz
• Solder-LESS LED Board Connections – Vibration Resistant
• Dual Drivers - Redundant Systems (built-in backup)

• LM80-08* Measurement of lumen maintenance for LED light sources
• LM79-08* Certified “Absolute” Photometry, including Chromaticity Color for Solid State Lighting
• L70 Values - Industry Nomenclature for Hours of use to 70% of Initial Lumens
• Factory Sealed Construction - no external seal required, simply wire mouting cap and threadin fixture to install.

 

 

7. KILLARK LED KFLC Series, "Compact Flood"

 

 

Applications
LED Compact Floods are designed for installations where moisture, dirt, dust, corrosion and vibration may be present, or NEMA 3 and 4X areas where wind, water, snow or high ambients can be expected. They can be used in locations made hazardous by the presence of flammable vapors or gases or combustible dusts as defined by the NEC.
Typical applications include spot lighting or walkways in manufacturing plants,
and certain chemical and petrochemical processing facilities, sewage treatment
plants, off-shore and dockside installations, garages and storage facilities

Compliances
• UL-8750 for LED lighting
• ANSI/UL 1598 (A)
• UL-844 Standard for lighting fixtures for hazardous locations, Class I,
Division 1; Class II, Division 1; Class III
• CSA C22.2 no. 137-M1981 electric luminairies for use in hazardous
locations
• Enclosed and gasketed
• NEMA 3, 4X, IP66

 

Materials
• Body and lens frame corrosion resistant copper-free aluminum alloy with
baked powder epoxy/polyester finish, electrostatically applied for complete,
uniform corrosion protection
• All external hardware - stainless steel
• Thermal shock and impact resistant extra heavy-duty glass lens
• High temperature silicone gasketing
• Trunnion heavy gauge galvanized steel with painted finish

 

LED Flood Features and Standards
• One 3/4” NPT hub & R-21 3/4” x 1/2” reducer is standard
• Crisp White Light for Excellent Color Rendering - Chromaticity 5000K (CCT); approx. 70 CRI
• Energy Savings - High lumens per watt
• Long Life - 80,000 maintenance free hours to 70% initial lumens
• Ambient suitability -40˚C to 55˚C
• Instant On - Including after power interruption
• Solder-LESS LED Board Connections - Vibration Resistant
• LM80-08* Measurement of lumen maintenance for LED light sources
• LM79-08* Certified “Absolute” Photometry, including Chromaticity
Color for Solid State Lighting
• L70 Values - Industry Nomenclature for Hours of use to 70% of initial
Lumens - TM-21* & calculated

 

 

8. KILLARK LED KFL Series, "CID2 Flood"

 

Applications
LED Floods are designed for installations where moisture, dirt, dust, corrosion and vibration may be present, or NEMA 3 and 4X areas where wind, water, snow or high ambients can be expected. They can be used in locations made hazardous by the presence of flammable vapors or gases or combustible dusts as defined by the NEC.
Typical applications include manufacturing plants, and certain chemical and petrochemical processing facilities, sewage treatment plants, off-shore and dockside installations, garages and storage facilities

 

Compliances
• UL-8750 for LED lighting
• ANSI/UL 1598(A)
• UL-844 Standard for lighting fixtures for hazardous locations, Class I,
Division 2; Class II, Divisions 1 and 2; Class III
• CSA C22.2 no. 137-M1981 electric luminairies for use in hazardous
locations
• Enclosed and gasketed
• NEMA 3, 4X, IP66
• IEX suffix Zone 2 to EN Standards

 

Materials
• Body, end caps and lens frame corrosion resistant copper-free aluminum alloy with baked powder epoxy/polyester finish, electrostatically applied for
complete, uniform corrosion protection
• All external hardware - stainless steel
• Thermal shock and impact resistant glass lens
• High temperature silicone gasketing
• Trunnion heavy gauge galvanized steel with painted finish

 

LED Flood Features and Standards
• Crisp White Light for Excellent Color Rendering - Chromaticity
5000K (CCT); approx. 70 CRI
• Energy Savings - High lumens per watt
• Long Life - to 150,000 maintenance free hours to 70% initial lumens
• Ambient suitability -50°C to 55°C
• Instant On - Including after power interruption
• World Voltage 120 - 277VAC 50/60Hz
• Solder-LESS LED Board Connections - Vibration Resistant
• LM80-08* Measurement of lumen maintenance for LED light sources
• LM79-08* Certified “Absolute” Photometry, including Chromaticity
Color for Solid State Lighting
• L70 Values - Industry Nomenclature for Hours of use to 70% of initial Lumens - TM-21* & Calculated

 

 

9. KILLARK LED KF1L Series, "CID1 Flood"

 

Applications
LED KF1L Series Explosion-proof Floods are designed for installations where moisture, dirt, dust, corrosion and vibration may be present, or NEMA 3 and 4X areas where wind, water, snow or high ambients can be expected. They can be used in locations made hazardous by the presence of flammable vapors or gases or combustible dusts as defined by the NEC.
Typical applications include manufacturing plants, and certain chemical and petrochemical processing facilities, sewage treatment plants, off-shore and dockside installations, garages and storage facilities

 

Compliances
• UL-8750 for LED lighting
• ANSI/UL 1598A
• UL-844 Standard for lighting fixtures for hazardous locations, Class I,
Division 1; Class II, Division 1; Class III
• CSA C22.2 no. 137-M1981 electric luminairies for use in hazardous
locations
• Enclosed and gasketed
• NEMA 3, 4X, IP66

 

Materials
• Body, end caps and lens frame corrosion resistant copper-free aluminum alloy with baked powder epoxy/polyester finish, electrostatically applied for
complete, uniform corrosion protection
• All external hardware - stainless steel
• Thermal shock and impact resistant extra heavy-duty glass lens
• High temperature silicone gasketing
• Trunnion heavy gauge 316 SS

 

LED Flood Features and Standards
• Factory Sealed Construction
• Two 3/4 NPT entries (see logic for other choices)
• Supplemental surge protection (AC models) and looping terminals
are standard
• Crisp White Light for Excellent Color Rendering - Chromaticity
5000K (CCT); approx. 70 CRI
• Energy Savings - High lumens per watt
• Long Life - 80,000 maintenance free hours to 70% initial lumens
• Instant On - Including after power interruption
• World Voltage 120 - 277VAC 50/60Hz
• Solder-LESS LED Board Connections - Vibration Resistant
• LM80-08* Measurement of lumen maintenance for LED light sources
• LM79-08* Certified “Absolute” Photometry, including Chromaticity
Color for Solid State Lighting
• L70 Values - Industry Nomenclature for Hours of use to 70% of initial
Lumens - TM-21* & calculated

 

 

10. KILLARK LED EBS Series, "Emergency Battery System" 

Applications
Where required by the NEC (or local “Life Safety” code) for safe egress (over
doors, aisleways, stairs, walkways, exit paths, and outer perimeter walls) to
provide illumination during interruption of normal power to area lighting.
In indoor or outdoor locations made hazardous by the presence of flammable
gas, vapors, or dusts. Includes refinery/chemical production and storage, grain processing, waste water treatment facilities and any area requiring heavy-duty dependable emergency lighting.

 

Exclusive Features
• LED Heads provide clear crisp illumination at 5000Kk
• LED Head L70 value 100,000 hours for minimal maintenance
• Up to 500% brighter than competitive conventional unitsl
• Enclosure Type 4 (NEMA 4) for wet and harsh locations
• Group B is standard when using EBSHK type heads
• Automatic Safety Disconnect - Removing main cover disconnects
battery power
• Ambient Suitability 0°C to 45°C Battery Unit; Heads to 55°
• Compact unit requires only two mounting points
• World Voltage 120-277 VAC 50/60Hz input

 

Other Features
• High % of lumens maintained during 90 minute egress cycle
• EBSHK type heads are fully adjustable on unit or remote when ordered with
RFSL Factory Sealed mounting kits

• EBSEL type heads are factory sealed on their EZ type mounting boxes
• Heads can be remote mounted over 300’ from battery unit
• Ni-Cad sealed batteries provide 90 minutes of illumination
• Integral base unit LED pilot light indicates AC power is present
• Choice of Integral or Remote Push-To-Test station to verify
system operation
• Vapor Capsule to inhibit corrosion is standard with main enclsure unit
• Terminal Blocks identified for incoming and outgoing connections

 

Compliances
• UL 1598 Standard for Luminaires
• UL 8750 for LED Lighting
• UL 844 Luminaires for Hazardous Locations
• UL 1203 Explosion-Proof/Dust-Ignition-Proof Electrical Enclosures
• UL 924 Emergency Lighting
• CSA C22.2 no. 137-M1981 Luminaires for Hazardous Locations
• CSA C22.2 no. 30-M1986 C1D1 Enclosures
• CSA 22.2 no. 25-1066 C2D1 EFG Enclosures
• Enclosure Type 4
• NEMA 4, 7BjCD, 9EFG

 

Materials
• Main Enclosure and Heads Copper Free Aluminum alloy with Baked
Powder epoxy/polyester finish, electro statically applied for complete,
uniform corrosion protection
• Attachment fittings copper-free aluminum
• External hardware 316 Stainless Steel
• EBSEL reflectors EXIT accessory aluminum with white paint


 

 

What makes Killark LED products GREEN?

 

Hubbell is committed to be a recognized leader

in conserving natural resources to sustaion our environment.

 

 

 

 

 

Original_V3_2014_LED_Mini_CAT_WEB.pdf

 

 

 

 

 

 

내 기술지원 및 구매상담

CUSTOMER SUCCESS IDK

deric@jadongwha.com

www.tiatip.com

 

 

 

+ Recent posts