보안울타리감지시스템 Senstar Barrier sensor : Taut Wire 사양자료 소개

 

안녕하세요 TIATIP 입니다. 지난 시간에 이어 이번에는 보안울타리감지시스템을 위한 Barrier Sensors : Taut Wire를 활용한 사례 및 사양을 살펴보도록 하겠습니다.

 

 

 

Senstar

Barrier Sensor

Taut Wire

보안울타리감지시스템

Intrusion Detection Systmes

Taut Wire intrusion detection sensor (TWIDS)

 

Highly rugged. Extremely reliable.

 

 

Description – Senstar’s taut wire perimeter intrusion detection system is designed to detect and physically prevent intrusions by unauthorized personnel into high security sites. Its key advantage is that it has no environmental limitations and has a very high Probability of detection (Pd) and a virtual absence of false and nuisance alarms.

 

Applicat ion – The system consists of multiple horizontal barbed or smooth wires along a typical segment of 60 meters (196.85 ft.), connected to a sensor post located halfway between adjacent anchor posts. It is also possible to protect buildings or walled areas by mounting it on outrigger-type posts.

 

 

 

 

Features
• High Probability of detection (Pd)
• Very low Nuisance Alarm Rate (NAR)
• Very low False Alarm Rate (FAR)
• Physical intrusion barrier
• No field adjustments required
• No height or length limitations

 

 

Benefits
• Combines high-performance sensor with a physical barrier
• Low maintenance costs
• Unaffected by Electromagnetic Interference / Radio Frequency  Interference (EMI / RFI)
• Operates in wide variety of environments including desert conditions, severe storms, humid climates and snow covered areas
• The system has less than 1 false alarm per kilometer per 3 months
• Constant sensitivity
• Simple integration with control unit - power and data on one
cable

 

 

 

How it works
The heart of this system is an electro-mechanical sensor which, upon sensing a predetermined amount of wire deflection, sends a signal to a Sensor Post Reporting Unit (SPRU). The SPRU in turn communicates the alarm information over an RS-422 serial connection. The Security Management System (SMS) accepts the serial data, sounds an alarm and provides a clear indication of the type and location of the intrusion attempt on the display screen.

 

 

Performance
Some alarm systems have an unacceptable number of false and nuisance alarms. As a result, an alarm can be disregarded by security staff with serious results. This taut wire system is free of this problem. The system has less than one false alarm per kilometer per three months. The Probability of detection (Pd) approaches 100%. Cutting or spreading fence wires, climbing over them on a ladder or through them, cutting the communication cable or trying to tamper with the sensor causes an immediate alarm. Forces less than approximately 15 kg (33 lbs.) will not activate the sensor, and therefore, small animals such as rabbits, dogs, snakes, birds etc., will not cause false alarms.

 

 

 

Markets
• Airports / ports / borders
• Energy & utilities - refineries / nuclear / chemical plants
• Military installations
• Correctional facilities
• Industrial sites

 

Taut wire technology
Senstar’s patented electro-mechanical sensor has a self adjustment
mechanism that ignores any slow wire movements due to soil movement
or temperature changes but will respond to an intrusion attempt. Its
sensitivity to wire movements by intrusion attempts is factory-set and
remains constant over the life of the system.


Sensors are mounted on sensor posts located halfway between adjacent
anchor posts. An array of tensioned barbed (or barb less) wires are
run between the anchor posts. Each wire is clamped to a sensor at the
sensor post location - each of two adjacent wires are connected to one
sensor. A pre-defined deflection of the wire causes an alarm. The wires
are spaced sufficiently close together to make it impossible for an intruder
to penetrate the array without causing an alarm. For alarm reporting
purposes, the sensors in each sensor post are divided into a maximum of
six (6) separate alarm groups.

 

 

 


The monitoring of the sensors and alarm reporting is accomplished
through the state-of-the-art SPRU installed on each sensor post and
linked to an SMS by a communication cable. Each sensor post is
protected against tampering by a tamper proof cover which generates
an alarm when removed. The tamper alarm is reported via the
communications cable and can be monitored by an SMS.


Optional add-on systems
Through integration with an overall SMS, additional alarm devices, such
as floodlights, sirens, CCTV cameras, etc. may be activated in response
to an intrusion attempt – either manually or automatically in response
to a sensor alarm. Alarm device activation can be done by using the
integrated output capability of the SPRU device or by a separate output
device.


Augmenting with a CCTV system controlled by an integrated SMS,
security staff can visually confirm an intrusion attempt by viewing the
intruder on a monitor, without having to watch that monitor constantly.

Universality
The system is unaffected by EMI / RFI or by climatic conditions. It is
protected against lightning and can be supplied for any site length,
terrain, reasonable system height or configuration.

 

 

 

System components
Field Mounted Equipment
• Sensor posts
• Anchor posts
• Carrying post attachment devices
• Sliding devices and intermediate spirals
• Communications cable for connection to SPRUs
• Sensor activating wire (barbed or un-barbed)
• Tensioning and clamping accessories

 

 

TYPICAL configuration


A typical installation consists of a 2 m (6.6 ft.) vertical component along
with a 1 m (3.3 ft.) inclined outrigger with 20 taut wires on the vertical
component and 10 taut wires on the inclined outrigger

Sensitivity: Fixed and independent of climatic conditions

Deflection force: 15 to 30 kg (33 to 66 lbs.) of force or more will activate an alarm

 

False Alarm Rate (FAR): Less than one per 1 kilometer per three months


Temperat ure range: -40º C to +72º C (-40º F to +160º F)


Relat ive humidity: Up to 100% non condensing


Rain, hail, snow, dust, UV radiat ion:
• Unaffected
• Trouble and maintenance-free in desert conditions, severe storms, tropical climates and sub-zero snow covered areas


Corrosive at mosphere:
• Suitable for almost all environments
• A stainless steel version is available for exceptional conditions

EMI / RFI : Complies with MIL-STD-461/462

SENSOR MTBF : 25 million hours


MTTR: 30 minutes


 

 

 

Technical Data

센스타, 보안울타리감지시스템, 보안울타리경비과학화시스템, 외곽울타리감지시스템, 외곽울타리경비과학화시스템, 과학화보안설비, 과학화경계시스템, Senstar, Taut Wire, TWIDS, DE-5000, BVS-5000, DTR-2000, Taut Wire Plus XField

Taut Wire 201205XX EN.pdf Senstar Corporate BRO 20150805 EN.pdf Senstar Product Line Card 2015XXXX EN.pdf

 

Note : Specifications are subject to change without notice.

소개된 제품 시스템의 사양, 재질, 치수, 기타 기재 내용은 제조공급사의 사정이나, 성능향상을 위해 예고 없이 단종, 대체되거나 변경되는 경우가 있으므로 양해를 부탁 드립니다. 기타 문의 상담은 하기 전문점을 통해 진행해 주시기 바랍니다. 

 

 

 

 

 

국내 상담문의 및 기술지원

CUSTOMER SUCCESS IDK

deric@jadongwha.com

www.tiatip.com

 

 

저작자 표시
신고
Posted by TIATIP

댓글을 달아주세요:: 네티켓은 기본, 스팸은 사절

과학화경계시스템 SENSTAR 펜스설치용 침입감지센서 FlexZone 소개자료

 

안녕하세요 TIATIP 입니다. 오늘 이 시간에는 과학화경계시스템, 과학화보안설비(Scientific Security System) 분야 울타리, 펜스(Fence)부분에 중점을 둔 보안울타리감지시스템, 외곽울타리경비과학화시스템, 외곽과학서 무인경비시스템에 대해 살펴보도록 하겠습니다. 센스타 Senstar 에서는 최고의 기술과 다양한 경험을 바탕으로 펜스 설치용 침입감지센서를 FlexZone 이라는 전문 제품군으로 다양한 환경과 고객의 니즈에 부응하고 있습니다.

 

 

 

Senstar

FlexZone

Ranging Fence-Mounted Intrusion Detection Sensors

외곽울타리경비과학화시스템을 위한 펜스설치용 침입감지센서

 

 

 

 

Features & Benefits

• Detect and locate perimeter intrusions over a distance of up to 600 m
(1,968 ft) per sensor processor
• Pinpoint intrusions with ±3 m (±10 ft) accuracy
• Flexible, software-based zoning (up to 60 distinct zones per processor)
• Precision sensitivity leveling (per meter)
• Power and data over sensor cables simplify infrastructure requirements
• High Probability of detection (Pd)
• Environmentally Derived Adaptive Processing Technology (EDAPT)
• Sensor cables are easily installed on a variety of fence types
• Communication path redundancy ensures continued perimeter protection in the event of a cable cut
• Low power consumption
• Software-configurable output relays simplify integration with alarm monitoring systems
• Audio output of fence response
• Silver Network compatibility enables integrated networking with OmniTrax®, FlexPS™, μltraWave™ and XField® systems
• Optional Ethernet card with Power over Ethernet (PoE) capability
• Sensors calibrated with Windows®-based point-and-click utility (over the network or locally via USB)
• Interfaces with almost any alarm monitoring system
• Internal alarm queuing in case of network interruption

 

 

 

OVERVIEW
FlexZone™ is Senstar’s latest generation ranging fence-mounted sensor. FlexZone detects and locates any attempt to cut, climb or otherwise break through the fence. It accurately locates intrusions even when there are multiple simultaneous intrusions and in the presence of background environmental noise.


Advanced Digital Signal Processing (DSP) enables FlexZone to adapt to a wide variety of fence types. FlexZone builds upon Senstar’s 30 plus years of perimeter security experience to deliver a sensor that is simple to install, supports remote configuration and alarm reporting, and works reliably in the most harsh environments.

 

 

 

HOW IT WORKS
By monitoring the minute flexing of its sensor cable, FlexZone detects and locates intruders climbing, cutting or lifting the fence fabric. High-speed sampling ensures that the FlexZone processor captures a precise picture of the fence signal.

 

 

ENVIRONMENTAL DISCRIMINATION
FlexZone differentiates between point disturbances caused by real intrusions and spatially distributed environmental disturbances like wind and rain. Unlike a block sensor, where all events are aggregated together
along the entire zone length (including ones caused by distributed environmental conditions), FlexZone divides the events into precise, localized areas, thus maximizing the probability of detection while reducing nuisance alarms.

 

 

ENVIRONMENTALLY DERIVED ADAPTIVE PROCESSING TECHNOLOGY (EDAPT)
Senstar’s Environmentally Derived Adaptive Processing Technology (EDAPT) mitigates the effects of wind and heavy rain. Using its precision ranging capability, FlexZone accounts for the background environmental noise level
in the vicinity of a disturbance before declaring an alarm. Implemented on each processor, EDAPT reduces nuisance alarms in both networked and non-networked processors.

 

 

SIMPLE INSTALLATION
The sensor cable is attached directly to the fence fabric with UV-resistant nylon cable ties. The processor unit is outdoorrated and can be mounted on a fence post or other surface.

 

 

REDUCED INFRASTRUCTURE COSTS
The sensor cable can carry both power and data, which greatly reduces power distribution and data communication cable requirements. For larger sites, multiple processors can be linked together and share common power sources and network connections.

 

 

 

FLEXIBLE ZONING
Each FlexZone processor supports up to 600 m (1,968 ft) of sensor cable. The sensor can be configured in software to support up to 60 distinct, individually sized detection zones. Zones enable a single sensor cable to be used across areas with different operational requirements (e.g., high-traffic areas like gates or entrances) and to provide location data for
integration with video surveillance and other security devices.

 

 

 

 

PRECISION SENSITIVITY LEVELING
The sensor cable is configured and calibrated with Senstar’s Windows®-based Universal Configuration Module (UCM) software.The UCM enables per meter sensitivity leveling and includes a real-time plot mode for viewing fence response data. The UCM software can run on a laptop connected via USB. If the processor is networked, remote access is also supported.

 

 

FENCE TYPES
FlexZone works with chain-link, standard welded mesh and expanded metal mesh fences. On barbed wire, concertina or areas where the sensor cable may be subject to damage, armored sensor cable is available. FlexZone may also be used on other types of fences, with a trial installation being done on a representative section to verify performance

 

 

 

 

 

GATE OPTIONS
FlexZone cable can be installed on swinging gates to provide detection, and the gate area itself can be configured as an independent detection zone. Gate contacts can be connected to the processor’s auxiliary inputs for integrated site monitoring.


For infrequently used gates, a quick-disconnect kit enables the cable to be installed in a contiguous run across the gate while still enabling the gate to be opened when required.


To protect sliding gates, Senstar’s μltraWave microwave can be integrated with FlexZone to provide a comprehensive, cost-effective solution. A FlexZone processor receiving power over the sensor cables can power an μltraWave sensor (Tx/Rx pair). If both devices include network cards, FlexZone also provides network connectivity.


For third-party devices like PIRs, FlexZone provides drycontact inputs to convey alarms to the site’s Security Management System (SMS) and can repurpose its power port to provide up to 2.0W of power.

 

 

 

RELAY OUTPUTS AND DRY-CONTACT INPUTS
Each processor includes four relay outputs and two dry-contact inputs. In stand-alone mode, the function of each relay is individually configured. In network mode, the relays may be controlled by the Security Management System (SMS) and are programmable for output type (steady, flash mode or pulse).


The dry-contact inputs serve as self-test inputs in standalone mode. In network mode, they serve as auxiliary inputs for the SMS and are programmable regarding their active state (open/closed) and resistor supervision mode.

 

 

NETWORKING AND INTEGRATION
Alarms can be reported locally at the processor via output relays or communicated to a central location over a network. FlexZone uses the sensor cable itself for conveying alarm, status, and configuration information. The sensor network can be polled from both ends of the perimeter, thus providing redundant data paths. If network connectivity is lost, alarms are queued internally and resent when connectivity is re-established.


The sensor network connects to the control room via EIA‑422, single or multi-mode fiber, or Ethernet links. Senstar’s Windows®-based Network Manager conveys alarm and status information to a Senstar or third-party Security Management System (SMS).


For integration with third-party systems, Senstar provides an SDK that includes API documentation, a Network Manager simulator, and complete sample code. The Network Manager also supports customizable ASCII text output. For information about integrating Senstar sensors, see the μltraLink Sensor Integration datasheet.

 

 

 

PROCESSOR SPECIFICATIONS
Main features
• Detect and locate intrusions on up to 600 m (1,968 ft) of active sensor cable per processor
• Pinpoints intrusions within ±3 m (±10 ft)
• Environmentally Derived Adaptive Processing Technology (EDAPT) lowers
Nuisance Alarm Rate (NAR) by mitigating the effects of wind and rain
• The Probability of detection (Pd) of an intruder cutting the fence, lifting the fence fabric, or climbing unaided over the fence shall be a minimum of 95% with a 95% confidence factor, when the system is installed in  accordance with the manufacturer’s directions on a high-quality fence
• Calibration and operating parameters configured via UCM software
• Audio output of fence response
• Available in two models:
• FlexZone-4: Supports up to 4 zones
• FlexZone-60: Supports up to 60 zones Environmental specifications
• Temperature: –40 to 70 °C (–40 to 158 °F)
• Humidity: 100% (condensing)
• Rugged all-weather painted aluminum UL, NEMA Type 4X (IP66) enclosure with hinged, locking cover Electrical specifications
• Input power: 10 to 60 VDC
• Consumption: 2.0W (base processor), 2.5W with communications card
• Power over sensor cables: 48V, 50W power supply required
• Power supply sharing: Up to 5 processors per power supply (power is shared over sensor cables to the two adjacent processors on each side)
• Auxiliary power output: 2.0W, 34 to 60 VDC
• Lightning protection: Transient voltage protection on all inputs and outputs, including power Physical specifications
• Dimensions (L/W/D): 31.6 x 18.6 x 9.0 cm (12.5 x 7.3 x 3.5 in), including cable glands and mounting brackets
• Weight: 1.2 kg (2.6 lbs)
• 5 cable entry points with compression glands (includes filler plugs)
• External ground lug Supervision/self-test features
• Monitoring of the sensor cable to detect opens, shorts and grounding
• Enclosure tamper switch
• Monitoring of critical processor parameters On-board storage
• Sensor data backup to onboard SD card
• Alarm queuing in the event of a network interruption

 

 

RELAY OUTPUTS AND AUXILIARY INPUTS
• 4 Form C output relays, 1.0A at 30VDC
• Relays can be controlled locally or over the network
• Function of each relay can be assigned based on requirement
• Assignable functions under local control include: alarm, supervision, door tamper, power fail and fail-safe
• Activation time programmable from 0.125 to 10 seconds
• In network mode, relays programmable for activation type and timing
• Two self-test inputs, one per cable side, become auxiliary dry contact inputs when processor is operating in network mode
• Auxiliary inputs are programmable for supervision type, resistor value(s) and filtering

 

 

OPTIONAL NETWORK CARDS
• EIA-422 network card with A and B side Tx/Rx connections for Silver networks
• Multi-mode fiber optic network card with ST connectors (820 nm) to support A and B side Tx/Rx connections for Silver network. Allows distances of up to 2.2 km (7,200 ft)
• Single-mode fiber optic network card with ST connectors (9/125 single-mode fiber, 1310 nm) with A and B side Tx/Rx connections for Silver network. Allows distances of up to 10 km (32,000 ft)
• 10/100BASE-TX Ethernet card with PoE option (provides power and communications to sensor processors over one cable)

 


USER-PROGRAMMABLE PARAMETERS
• Fence type, gain, filter, and disturbance count parameters
• Stand-alone or network configuration
• Relay function assignment and operating mode
• Auxiliary input supervision parameters

 

UNIVERSAL CONFIGURATION MODULE (UCM) SOFTWARE
• Windows®-based, point-and-click interface for configuring and calibrating the processor
• Communicates with FlexZone processor via local USB connection or over network
• Precise sensitivity leveling (per meter)
• View real-time sensor data and save for later analysis

 

 

 


SENSOR CABLE OPTIONS


FlexZone sensor cable rolls
• High density polyethylene jacket
• Cable length: 150 m (492 ft)
• Cable outside diameter: 7 mm (0.27 in)
• Roll dimensions (H/W/D): 48 x 48 x 23 cm (19 x 19 x 9 in)
• Roll weight: 9.0 kg (20 lbs)

 

FlexZone sensor cable in protective flex conduit
• Cable length: 150 m (492 ft)
• Cable outside diameter: 14 mm (0.56 in)
• Roll dimensions (L/W/D): 46 x 46 x 28 cm (18 x 18 x 11 in)
• Roll weight (approximate): 38 kg (84 lbs)


CABLE ACCESSORIES
• UV-resistant cable ties
• Stainless steel cables ties with installation tool
• Waterproof cable terminators and splice kits
• Condulet – splice protection for armored cable


GATE OPTIONS
• Quick disconnect connector kit REGULATORY COMPLIANCE
• CE (including RoHS 2)
• FCC
• REACH

 

 

 

 

지금까지 센스타 Senstar의 과학화경계시스템, 과학화보안설비(Scientific Security System) 분야 울타리, 펜스(Fence)부분에 중점을 둔 보안울타리감지시스템, 외곽울타리경비과학화시스템, 외곽과학서 무인경비시스템에 대해 살펴보았습니다. 국내 항송사 및 발전소, 변전소 등 까다롭고 다양한 니즈에 대응하며, 현재 주요 SI업체들과의 협업을 통한 고객만족, 고객성공을 지원하고 있습니다.

 

Technical Data

Senstar, Magal, FlexZone, Flex-Zone, 센스타, 마갈, 보안울타리감지시스템, 외곽울타리경비과학화시스템, 과학화보안설비, 외곽과학화무인경비시스템, 과학화경계시스템, 외곽경계시스템, 보안, 안전, 감시, 모니터링, 경계, 경보, 안보, 방위, 침입감지, 감지, 경고, 주의, 전시, 방호, 보호, 외곽경비, 외곽울타리경보, 외곽펜스경보, 외곽보안경비, 외곽보안경비시스템, 외곽보안시스템, 울타리칩입감지시스템, 울타리펜스,보안펜스,외곽보안, 외곽방호, 물리보안, 과학화보안, 침입감지보호, 울타리감시시스템, 첨단보안, 종합보안시스템, 시스템경비, 지상무인감시스템, 감시정찰네트워크, 지상복합무인감시시스템, 과학화외곽경계시스템, 보호감시시스템, 감시보안시스템, 보호감시솔루션

FlexZone Datasheet 201502XX EN.pdf FlexZone Datasheet 20160308 KR.pdf

Note : Specifications are subject to change without notice.

소개된 제품 시스템의 사양, 재질, 치수, 기타 기재 내용은 제조공급사의 사정이나, 성능향상을 위해 예고 없이 단종, 대체되거나 변경되는 경우가 있으므로 양해를 부탁 드립니다. 기타 문의 상담은 하기 전문점을 통해 진행해 주시기 바랍니다. 

 

 

 

 

국내 상담문의 및 기술지원

CUSTOMER SUCCESS IDK

deric@jadongwha.com

www.tiatip.com

 

저작자 표시
신고
Posted by TIATIP

댓글을 달아주세요:: 네티켓은 기본, 스팸은 사절


BLOG main image
by TIATIP

카테고리

TI Story (949)N
TIA (92)
TIP (194)
TIEx (593)N
TIS (36)
TIO (23)
TiNoTe (10)
The OtherS (1)