호크 Hawke 501/453/Universal Cable Gland 기술사양

 

안녕하세요 TIATIP 입니다.

 

오늘은 501/453/Universal (이하, 501/453/UNIV) 시리즈에 대하여 살펴보겠습니다.

Cold Flow Characteristics 를 충족하는 대표적인 아이템으로 선박과 중공업 및 해상플랜트에 많이 적용되고 있습니다.

 

 

Hawke

Group II Hazardous Area

Flameproof Exd / Increased Safety Exe

Restricted Breathing ExnR / Dust Extb

Dual Certified ATEX - IECEx

 

 

Application

Outdoor or indoor use.
For use with single wire armour ‘W’, wire braid ‘X’ and steel tape armour ‘Z’ elastomer and plastic insulated cables.
For particular use with cables that exhibit 'cold flow' characteristics.

 

 

 

 

 

Features

Provides armour clamping using one clamping arrangement for all armour/braid types.
Provides a diaphragm seal on the cables inner sheath which will not damage cable that has 'cold flow' characteristics.
Provides an outer deluge seal to prevent moisture ingress to the cable armour/braid.
Provides a cable retention and low smoke and fume, zero halogen seal onto the cables outer sheath.

 

 

 

 

Materials & Finishes

The 501/453/Universal cable gland is manufactured in Brass (standard), Nickel Plated Brass, 316 Stainless Steel or Aluminium. Brass NPT entries are nickel plated as standard. 

 

 

1. Unique Rear Sealing System

This arrangement offers IP66, IP67, IP68 (30 metres for 7 days), NEMA 4X and Deluge (DTS01) Ingress Protection.

The seal is manufactured from a silicone material, has LSFZH properties, is ozone and oil resistant and is suitable for use at both high and low temperatures. The Rear Sealing System covers the entire range of cable diameters without the need for special seals and the cable acceptance range is stamped on the backnut for ease of inspection. The backnut can be hand tightened, with only one further spanner turn required to ensure IP66, IP67, IP68 and NEMA 4X.

 

2. The Original Reversible Armour Clamp

The original RAC clamping system was invented by Hawke over 10 years ago and is a well established proven performer in all conditions. Simply by reversing the clamping ring, the cable gland can adjust to accommodate all types of cable armour or braid. Unlike many of our competitors, the correct stamping orientation is marked clearly with the armour size and backed up by the presence of a groove in the component. Our RAC clamping system is also fully inspectable when positioned on the cable.

 

3. Zero Cable Damage

Our unique diaphragm sealing system does not damage cables which exhibit 'Cold Flow' characteristics. The diaphragm type seal is currently the only elastomeric seal to comply fully with IEC/EN 60079-14 and is therefore suitable on effectively filled 'cold flow' cables which would otherwise require barrier style cable glands. Our diaphragm seal is also unique in that it is the only flameproof elastomeric seal that can be visually inspected in operation - a real benefit to inspectors.

 

4.  Inspectable Deluge Seal

Our inspectable deluge seal offers IP66 and IP67 sealing and is certified as 'deluge proof' by ITS in accordance with DTS01. Indeed, our deluge seal is so good that it exceeds the expectations of the offshore industry by not only preventing ingress into the equipment, but also into the cable gland, which prevents corrosion of the cable armour.

 

 

 

 

Technical Data

1.Exd IIC Gb, Exe IIC Gb, ExnR IIC Gc, Extb IIIC Db

2.Certificate No's : Baseefa06ATEX0057X and IECEx BAS 06.0014X for sizes Os - F.

3.Baseefa06ATEX0056X and IECEx BAS 06.0013X for sizes G - J.

4.Suitable for use in: Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC.

5.Construction and Test Standards: IEC/EN 60079-0, IEC/EN 60079-1, IEC/EN 60079-7, IEC/EN 60079-15, IEC/EN 61241-0 and IEC/EN 61241-1.

6.Ingress Protection: IP66, IP67 and IP68 (30 metres for 7 days) to IEC/EN 60529 and NEMA 4X.

7.Deluge Protection to: DTS01

8.Operating Temperature Range: -60°C to +80°C

9.Assembly Instruction Sheet: AI 300 (Sizes Os to F). AI 303 (Sizes G to J).

 

 

 

 

Hawke Accessories

for 501/453/Universal (501/453/UNIV) 

 

 

 

Installation Guide

for Hawke 501/453/Universal Series

 

 

 

Hawke Order Format [Gland Type/Size/Thread/Options/Materials]

 

Example without options :501/453/UNIV/C/M32

 

Example without options, Nickel Plated Brass :501/453/UNIV/C/M32 Nickel Plated Brass

 

Example with alternative clamping ring option : 501/453/UNIV/C/1-1/4"NPT/AR

 

501/453/UNIV/Os/M16

501/453/UNIV/Os/M20

501/453/UNIV/Os/NPT1/2"

501/453/UNIV/O/M16

501/453/UNIV/O/M20

501/453/UNIV/O/NPT1/2"

501/453/UNIV/A/M20

501/453/UNIV/A/NPT1/2"

501/453/UNIV/A/NPT3/4"

501/453/UNIV/B/M25

501/453/UNIV/B/NPT3/4"

501/453/UNIV/B/NPT1"

501/453/UNIV/C/M32

501/453/UNIV/C/NPT1"

501/453/UNIV/C/NPT1-1/4"

501/453/UNIV/D/M50

501/453/UNIV/D/NPT1-1/2"

501/453/UNIV/D/NPT2"

501/453/UNIV/E/M63

501/453/UNIV/E/NPT2"

501/453/UNIV/E/NPT1-1/2"

501/453/UNIV/F/M75

501/453/UNIV/F/NPT2-1/2"

501/453/UNIV/F/NPT3"

501/453/UNIV/G/M80

501/453/UNIV/G/NPT3-1/2"

501/453/UNIV/H/M90

501/453/UNIV/H/NPT3-1/2"

501/453/UNIV/J/M100

501/453/UNIV/J/NPT4 

 

 

 

Technical Data

 

501453Universal Spec IDK.pdf

2.Hawke Accessories 2013 IDK.pdf

 

 

 

 

 

 

 

내 기술지원 및 구매상담처

CUSTOMER SUCCESS IDK

deric@jadongwha.com

www.tiatip.com

 

 

저작자 표시
신고
Posted by TIATIP

댓글을 달아주세요:: 네티켓은 기본, 스팸은 사절

Hawke 501453RAC Cable Glands

 

안녕하세요 TIATIP 입니다.

 

오늘은 Hawke 호크케이블 그랜드의 베스트셀러 501453RAC 를 소개합니다.

 

 

 

 

폭넓은 산업플랜트 어플리케이션으로 국내외 EPC사와 조선분야 마린 어플리케이션에서 가장 많이 찾고 계신 타입입니다.

 

Cable Glands
Hazardous Area
Flameproof Exd & Increased Safety Exe
Dual Certifi ed ATEX / IECEx

501453RAC Cable Glands

 

 

 

 

501/453RAC 시리즈의 일반적(Brass재질)인 품번은 다음과 같습니다.

최근에는 Nickel Plated Brass 재질을 많이 사용하고 있으며, 품번 끝에 해당 재질을 기재하면 됩니다. 또는 약식으로 Fully N.P. 라고 명시되기도 합니다.

 

 

501/453RAC 시리즈

 

 

501/453/RAC/Os/M20

501/453/RAC/O/M20 

501/453/RAC/B/M25 

501/453/RAC/C/M32

501/453/RAC/C2/M40

501/453/RAC/D/M50 

501/453/RAC/E/M63 

501/453/RAC/F/M75 

501/453/RAC/G/M80

501/453/RAC/H/M90 

501/453/RAC/J/M100

501/453/RAC/Os/1/2"NPT

501/453/RAC/O/1/2"NPT

501/453/RAC/A/M20

501/453/RAC/A/3/4"NPT

501/453/RAC/A/1/2"NPT

501/453/RAC/B/1"NPT

501/453/RAC/B/3/4"NPT

501/453/RAC/C/1-1/4"NPT

501/453/RAC/C/1"NPT

501/453/RAC/C2/1-1/2"NPT

501/453/RAC/C2/1-1/4"NPT

501/453/RAC/D/2"NPT

501/453/RAC/D/1-1/2"NPT

501/453/RAC/E/2-1/2"NPT

501/453/RAC/E/2"NPT

501/453/RAC/F/3"NPT

501/453/RAC/F/2-1/2"NPT

501/453/RAC/G/3-1/2"NPT

501/453/RAC/H/3-1/2"NPT

501/453/RAC/J/4"NPT

 

 

Application

• Outdoor or indoor use.
For use with single wire armour ‘W’, wire braid ‘X’ and steel tape armour ‘Z’

   elastomer and plastic insulated cables.

 

 

 

Features

Provides armour clamping using one clamping arrangement for all

   armour/braid types.
Provides a seal on the cables inner sheath.
Deluge protection option available, contact Hawke Technical Sales for details.
Provides a cable retention and low smoke and fume, zero halogen seal onto

   the cables outer sheath.

 

 

 

Materials & Finishes

The 501/453/RAC cable gland is manufactured in Brass (standard), Nickel

   Plated Brass, 316 Stainless Steel or Aluminium.
Brass NPT entries are nickel plated as standard.

 

 

악세서리

 

 

Technical Data

 

Exd IIC Gb, Exe IIC Gb, Extb IIIC Db
Baseefa Certificate No. Baseefa06ATEX0056X.
IECEx Certificate No. IECEx BAS 06.0013X.
Suitable for use in Zone 1, Zone 2, Zone 21 and Zone 22.
Suitable for use in Gas Groups IIA, IIB and IIC.
Construction and Test Standards: IEC/EN 60079-0, IEC/EN 60079-1, IEC/EN

   60079-7, IEC/EN 61241-0 and IEC/EN 61241-1.
Ingress Protection: IP66, IP67 and IP 68 (30 metres for 7 days) to IEC/EN

   60529 and NEMA 4X.
Deluge protection to DTS01 (Deluge seal optional).
Operating Temperature Range: -60°C to +80°C.
Alternative certification options available:

 

 

보다 상세한 자료는 첨부파일을 참고하시기 바랍니다.

 

Hawke 호크 501453RAC 01.pdf

Hawke 호크 Accessories 01.pdf

Hawke 호크 501453RAC 조립도 01.pdf

 

 

 

 

국내 기술지원 및 상담구매처

CUSTOMER SUCCESS IDK

deric@jadongwha.com

www.tiatip.com

 

 

저작자 표시
신고
Posted by TIATIP

댓글을 달아주세요:: 네티켓은 기본, 스팸은 사절


BLOG main image
by TIATIP

카테고리

TI Story (947)
TIA (92)
TIP (194)
TIEx (591)
TIS (36)
TIO (23)
TiNoTe (10)
The OtherS (1)