Hawke Additional NEC Approvals and CSA Approvals 사양소개

 

안녕하세요 TIATIP 입니다.

 

오늘 이 시간에는 Hawke International News, 케이블글랜드/케이블그랜드 제품군의 새로운 승인자료 업데이트분을 소개합니다.

 

 

 

501/421

501/414

501/423

501/453/RAC

501/453/Universal

ICG 623

ICG 653/Universal

CSB 656N

 

Additional NEC / CSA
Approvals for Cable Glands

Hawke International is pleased to announce an important addition to their comprehensive portfolio of international hazardous location approvals.

 

 

 

Canadian Standards Association, cCSAus approvals for both Canada
and America, including Classes and Zones and Classes and Divisions
now cover the following cable gland ranges for use with Marine
Shipboard Cables, Unarmoured and Conduits:-

501/421
501/421R
501/414
501/423
501/453 RAC
501/453
Universal
ICG623
ICG653
Universal
CSB656
CSB656N

 

Additional NEC / CSA Approvals

 

We are pleased to announce an important addition to our comprehensive portfolio of international hazardous location approvals. Canadian Standards Association, cCSAus approvals for both Canada and America, including Classes and Zones and Classes and Divisions now cover the following cable gland ranges for use with Marine Shipboard Cables and Conduits:-

 

These cable gland ranges will be marked with ATEX, IECEX, GOST-R, CEPEL- INMETRO and with cCSAus Class and Zones and Class and Division marking.

 

The additional marking includes:- the CSA Certification number, Class 1 Zone1, AExeII, AExdIIC, AExtD Zone 21, Class I Div 2 ABCD, Class II EFG, and Class III and covers gases, vapours and dusts.

 

These NEC/CSA cable gland ranges compliment the well established UL listed Hawke 7 Series cable glands.

 

This additional approval will provide an improved global certification approach to satisfy our customer’s requirements for a comprehensive range of safe and reliable, globally certified cable gland connection solutions.

 

 

 

 

 

 

NEC CSA Approvals Glands.pdf

1.Cable Glands-Group ll.pdf

1.Cable Glannds-Industrial.pdf

1.Cable Glands-Group I Mining.pdf

1.Cable Glands-American Series NEC,IEC.pdf

1.Cable Glannds-Selection chart.pdf

2.Hawke Accessories 2013 IDK.pdf

 

 

 

 

 

 

내 기술지원 및 구매상담처

CUSTOMER SUCCESS IDK

deric@jadongwha.com

www.tiatip.com

 

 

저작자 표시
신고
Posted by TIATIP

댓글을 달아주세요:: 네티켓은 기본, 스팸은 사절

호크 Hawke Group II Cable Gland Range 라인업소개

 

안녕하세요 TIATIP 입니다.

 

육상 및 해상플랜트 등 방폭위험지역에 주로 적용되는 Hawke Group II Cabel Gland Range 라인업을 소개드립니다. 

 

 

 

 

Hawke

Group II Cable Gland Range

For harsh and hazardous locations

 

 

What is a hazardous area cable gland?

 

Cable glands are designed to terminate cables into flameproof or increased safety equipment in hazardous areas. They provide a weather and gas-proof sealed connection between cable and equipment, prevent the cable being pulled out or twisted and provide a grounding of the cable armour.

 

 

 

 

The cost of a cable gland is insignificant when compared to that of other equipment. However, the cost of failure is high.

 

Though some cable glands may be "fit for purpose" what would be the potential cost of failure?

 

 

1. Hawke 501/421 Cable Gland

 

Exd IIC Gb, Exe IIC Gb, Extb IIIC Db

Non-armoured
ATEX IECEx Approved

 

 

 

 

2. Hawke 501/423 Cable Gland

 

Exd IIC Gb, Exe IIC Gb, Extb IIIC Db

Non-armoured
ATEX IECEx Approved

 

 

 

 

3. Hawke 501/453/RAC Cable Gland

 

Exd IIC Gb, Exe IIC Gb, Extb IIIC Db

Non-armoured
ATEX IECEx Approved

 

 

 

 

4. Hawke 501/453/RAC/L Cable Gland

 

Exd IIC Gb, Exe IIC Gb, Extb IIIC Db

Non-armoured
ATEX IECEx Approved

 

 

 

 

5. Hawke 501/453/Universal Cable Gland

 

Exd IIC Gb, Exe IIC Gb, ExnR IIC Gc, Extb IIIC Db

Armoured
ATEX IECEx Approved

 

 

 

 

6. Hawke PSG 553/RAC Cable Gland

 

Exe IIC, Exd IIC, Extb IIIC

Armoured
ATEX IECEx Approved

 

 

 

 

7. Hawke ICG/623 Cable Gland

 

Exd IIC Gb, Exe IIC Gb, Extb IIIC Db

Non-Armoured
ATEX IECEx Approved

 

 

 

 

8. Hawke ICG 653/Universal Cable Gland

 

Exd IIC Gb, Exe II Gb, Extb IIIC Db

Armoured
ATEX IECEx Approved

 

 

 

 

 

9. Hawke ICG 653/Universal/L Cable Gland

 

Exd IIC Gb, Exe II Gb, Extb IIIC Db

Armoured
ATEX IECEx Approved

 

 

 

 

10. Hawke 501/414 Cable Gland

 

Exd IIC Gb, Exe IIC Gb, Extb IIIC Db

Non-armoured
ATEX IECEx Approved

 

 

 

 

11. Hawke SB 474 Cable Gland

 

Exd IIC Gb, Exe IIC Gb, Extb IIIC Db

Non-armoured
ATEX IECEx Approved

 

 

 

 

 

12. Hawke CSB 656N Cable Gland

 

Exd IIC Gb, Exe IIC Gb, Extb IIIC Db

Non-armoured
ATEX IECEx Approved

 

 

 

 

Hawke Thread Conversion Solutions and Accessories

 

 

 

 

Hawke Thread Conversion Solutions and Accessories

 

 

 

Technical Data

 

1.Cable Glands-Group ll.pdf

2.Hawke Accessories 2013 IDK.pdf

 

 

 

 

 

 

 

내 기술지원 및 구매상담처

CUSTOMER SUCCESS IDK

deric@jadongwha.com

www.tiatip.com

 

 

저작자 표시
신고
Posted by TIATIP

댓글을 달아주세요:: 네티켓은 기본, 스팸은 사절

호크 Hawke 501/453/RAC Cable Gland 기술사양

 

안녕하세요 TIATIP 입니다.

 

오늘은 호크 Hawke 케이블글랜드를 대표하는 하나의 아이템인 501/453/RAC 시리즈를 살펴보겠습니다. 501/453/RAC 시리즈는 육상플랜트와 해상플랜트 전반에 걸쳐 현장요구에 폭넓게 대응하는 베스트셀러이자 대표 브랜드입니다.

 

 

Hawke 

Group II Hazardous Area

Flameproof Exd / Increased Safety Exe / Dust Extb

Dual Certified ATEX - IECEx

501/453/RAC Series

 

 

 

Application

Outdoor or indoor use.
For use with single wire armour ‘W’, wire braid ‘X’ and steel tape armour ‘Z’ elastomer and plastic insulated cables.

 

 

 

 

 

Features

Provides armour clamping using one clamping arrangement for all armour/braid types.
Provides a seal on the cables inner sheath.
Deluge protection option available, contact Hawke Technical Sales for details.
Provides a cable retention and low smoke and fume, zero halogen seal onto the cables outer sheath. 

 

 

 

 

Materials & Finishes

The Hawke 501/453/RAC cable gland is manufactured in Brass (standard), Nickel Plated Brass, 316 Stainless Steel or Aluminium. Brass NPT entries are nickel plated as standard.

 

 

 

 

Technical Data

1. Exd IIC Gb, Exe IIC Gb, Extb IIIC Db

2. Certificate No's : Baseefa06ATEX0056X and IECEx BAS 06.0013X.

3. Suitable for use in: Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC.

4. Construction and Test Standards: IEC/EN 60079-0, IEC/EN 60079-1, IEC/EN 60079-7, IEC/EN 61241-0 and IEC/EN 61241-1.

5. Ingress Protection: IP66, IP67 and IP68(30 metres for 7 days) to IEC/EN 60529 and NEMA 4X.

6. Deluge Protection to: DTS01 (Deluge seal optional).

7. Operating Temperature Range: -60°C to +80°C

8. Assembly Instruction Sheet: AI 302.

 

 

Installation Guide

for Hawke 501/453/RAC Series Cable Gland

 

 

 

 

Hawke Accessories


 

 

 

Technical Data

 

501453RAC Spec IDK.pdf

2.Hawke Accessories 2013 IDK.pdf

 

 

Hawke Order Format [Gland Type/Size/Thread/Options/Materials]

Example without options : 501/453/RAC/C/M32

Example without options, Nickel Plated Brass : 501/453/RAC/C/M32 Nickel Plated Brass

Example with alternative seal option : 501/453/RAC/C/1-1/4"NPT/S

Example with alternative clamping ring option : 501/453/RAC/C/1-1/4"NPT/AR

501/453/RAC/Os/M16

501/453/RAC/Os/M20

501/453/RAC/O/M16

501/453/RAC/O/M20

501/453/RAC/A/M20

501/453/RAC/B/M25

501/453/RAC/C/M32

501/453/RAC/C2/M40

501/453/RAC/D/M50

501/453/RAC/E/M63

501/453/RAC/F/M75

501/453/RAC/G/M80

501/453/RAC/H/M90

501/453/RAC/J/M100

501/453/RAC/Os/NPT1/2"

501/453/RAC/O/NPT1/2"

501/453/RAC/A/NPT1/2"

501/453/RAC/A/NPT3/4"

501/453/RAC/B/NPT3/4"

501/453/RAC/B/NPT1"

501/453/RAC/C/NPT1"

501/453/RAC/C/NPT1-1/4"

501/453/RAC/C2/NPT1-1/4"

501/453/RAC/C2/NPT1-1/2"

501/453/RAC/D/NPT1-1/2"

501/453/RAC/D/NPT2"

501/453/RAC/E/NPT2"

501/453/RAC/E/NPT2-1/2"

501/453/RAC/F/NPT2-1/2"

501/453/RAC/F/NPT3"

501/453/RAC/G/NPT3-1/2"

501/453/RAC/H/NPT3-1/2"

501/453/RAC/J/NPT4"

 

 

 

 

 

 

내 기술지원 및 구매상담처

CUSTOMER SUCCESS IDK

deric@jadongwha.com

www.tiatip.com

 

 

저작자 표시
신고
Posted by TIATIP

댓글을 달아주세요:: 네티켓은 기본, 스팸은 사절

호크케이블글랜드 라인업과 다운로드링크

 

안녕하세요 TIATIP 입니다.

Hawke(호크) 케이블글랜드 관련 자료를 다운로드할 수 있는 사이트링크를 요약해 드립니다.

 

 

 

Our Cable Glands cover the whole spectrum of armoured and non-armoured cable and applications from general industrial through increased safety, deluge, flameproof and explosion proof. The Cable Glands are available in Brass as standard with Stainless Steel and Aluminium, as an optional material on certain designs. The innovative design features included in the range make our Cable Glands the lowest lifetime cost solution.

 

 

Hazardous Area Cable Glands

Features

  • 501/414
  • 501/421
  • 501/423
  • 501/453/RAC
  • 501/453/RAC/L
  • 501/453/Universal
  • CSB 656N
  • ICG 623
  • ICG 653/Universal
  • ICG 653/Universal/L
  • PSG 553/RAC
  • SB 474
  •  

     

    Group 1 Mining

    Features

  • 453/RAC
  • 453/T
  • 453/Universal
  • 623
  • 653/T
  • 653/Universal
  •  

     

     

    North American Series Cable Glands

    Features

  • 153/X
  • 701
  • 710
  • 711
  • 713
  • 753
  • 755
  •  

     

    Industrial Cable Glands

    Features

  • 114
  • 121 (Type A2)
  • 123 (Type A2)
  • 150/RAC (Type BW, BX and BZ)
  • 151/RAC (Type CW, CX and CZ)
  • 153/RAC (Type E1W, E1X and E1Z)
  • 153/RAC/L (Type E2W, E2X and E2Z)
  • 153/Universal (Type E1W, E1X and E1Z)
  •  

     

    Increased Safety Cable Glands

    321

     

     

     

     

     

     

     

     

     

     

     

    국내 기술지원 및 상담구매처

    CUSTOMER SUCCESS IDK

    deric@jadongwha.com

    www.tiatip.com

     

     

    저작자 표시
    신고
    Posted by TIATIP

    댓글을 달아주세요:: 네티켓은 기본, 스팸은 사절


    BLOG main image
    by TIATIP

    카테고리

    TI Story (957)
    TIA (92)
    TIP (194)
    TIEx (601)
    TIS (36)
    TIO (23)
    TiNoTe (10)
    The OtherS (1)