Hawke Additional NEC Approvals and CSA Approvals 사양소개

 

안녕하세요 TIATIP 입니다.

 

오늘 이 시간에는 Hawke International News, 케이블글랜드/케이블그랜드 제품군의 새로운 승인자료 업데이트분을 소개합니다.

 

 

 

501/421

501/414

501/423

501/453/RAC

501/453/Universal

ICG 623

ICG 653/Universal

CSB 656N

 

Additional NEC / CSA
Approvals for Cable Glands

Hawke International is pleased to announce an important addition to their comprehensive portfolio of international hazardous location approvals.

 

 

 

Canadian Standards Association, cCSAus approvals for both Canada
and America, including Classes and Zones and Classes and Divisions
now cover the following cable gland ranges for use with Marine
Shipboard Cables, Unarmoured and Conduits:-

501/421
501/421R
501/414
501/423
501/453 RAC
501/453
Universal
ICG623
ICG653
Universal
CSB656
CSB656N

 

Additional NEC / CSA Approvals

 

We are pleased to announce an important addition to our comprehensive portfolio of international hazardous location approvals. Canadian Standards Association, cCSAus approvals for both Canada and America, including Classes and Zones and Classes and Divisions now cover the following cable gland ranges for use with Marine Shipboard Cables and Conduits:-

 

These cable gland ranges will be marked with ATEX, IECEX, GOST-R, CEPEL- INMETRO and with cCSAus Class and Zones and Class and Division marking.

 

The additional marking includes:- the CSA Certification number, Class 1 Zone1, AExeII, AExdIIC, AExtD Zone 21, Class I Div 2 ABCD, Class II EFG, and Class III and covers gases, vapours and dusts.

 

These NEC/CSA cable gland ranges compliment the well established UL listed Hawke 7 Series cable glands.

 

This additional approval will provide an improved global certification approach to satisfy our customer’s requirements for a comprehensive range of safe and reliable, globally certified cable gland connection solutions.

 

 

 

 

 

 

NEC CSA Approvals Glands.pdf

1.Cable Glands-Group ll.pdf

1.Cable Glannds-Industrial.pdf

1.Cable Glands-Group I Mining.pdf

1.Cable Glands-American Series NEC,IEC.pdf

1.Cable Glannds-Selection chart.pdf

2.Hawke Accessories 2013 IDK.pdf

 

 

 

 

 

 

내 기술지원 및 구매상담처

CUSTOMER SUCCESS IDK

deric@jadongwha.com

www.tiatip.com

 

 

저작자 표시
신고
Posted by TIATIP

댓글을 달아주세요:: 네티켓은 기본, 스팸은 사절

호크 Hawke Group II Cable Gland Range 라인업소개

 

안녕하세요 TIATIP 입니다.

 

육상 및 해상플랜트 등 방폭위험지역에 주로 적용되는 Hawke Group II Cabel Gland Range 라인업을 소개드립니다. 

 

 

 

 

Hawke

Group II Cable Gland Range

For harsh and hazardous locations

 

 

What is a hazardous area cable gland?

 

Cable glands are designed to terminate cables into flameproof or increased safety equipment in hazardous areas. They provide a weather and gas-proof sealed connection between cable and equipment, prevent the cable being pulled out or twisted and provide a grounding of the cable armour.

 

 

 

 

The cost of a cable gland is insignificant when compared to that of other equipment. However, the cost of failure is high.

 

Though some cable glands may be "fit for purpose" what would be the potential cost of failure?

 

 

1. Hawke 501/421 Cable Gland

 

Exd IIC Gb, Exe IIC Gb, Extb IIIC Db

Non-armoured
ATEX IECEx Approved

 

 

 

 

2. Hawke 501/423 Cable Gland

 

Exd IIC Gb, Exe IIC Gb, Extb IIIC Db

Non-armoured
ATEX IECEx Approved

 

 

 

 

3. Hawke 501/453/RAC Cable Gland

 

Exd IIC Gb, Exe IIC Gb, Extb IIIC Db

Non-armoured
ATEX IECEx Approved

 

 

 

 

4. Hawke 501/453/RAC/L Cable Gland

 

Exd IIC Gb, Exe IIC Gb, Extb IIIC Db

Non-armoured
ATEX IECEx Approved

 

 

 

 

5. Hawke 501/453/Universal Cable Gland

 

Exd IIC Gb, Exe IIC Gb, ExnR IIC Gc, Extb IIIC Db

Armoured
ATEX IECEx Approved

 

 

 

 

6. Hawke PSG 553/RAC Cable Gland

 

Exe IIC, Exd IIC, Extb IIIC

Armoured
ATEX IECEx Approved

 

 

 

 

7. Hawke ICG/623 Cable Gland

 

Exd IIC Gb, Exe IIC Gb, Extb IIIC Db

Non-Armoured
ATEX IECEx Approved

 

 

 

 

8. Hawke ICG 653/Universal Cable Gland

 

Exd IIC Gb, Exe II Gb, Extb IIIC Db

Armoured
ATEX IECEx Approved

 

 

 

 

 

9. Hawke ICG 653/Universal/L Cable Gland

 

Exd IIC Gb, Exe II Gb, Extb IIIC Db

Armoured
ATEX IECEx Approved

 

 

 

 

10. Hawke 501/414 Cable Gland

 

Exd IIC Gb, Exe IIC Gb, Extb IIIC Db

Non-armoured
ATEX IECEx Approved

 

 

 

 

11. Hawke SB 474 Cable Gland

 

Exd IIC Gb, Exe IIC Gb, Extb IIIC Db

Non-armoured
ATEX IECEx Approved

 

 

 

 

 

12. Hawke CSB 656N Cable Gland

 

Exd IIC Gb, Exe IIC Gb, Extb IIIC Db

Non-armoured
ATEX IECEx Approved

 

 

 

 

Hawke Thread Conversion Solutions and Accessories

 

 

 

 

Hawke Thread Conversion Solutions and Accessories

 

 

 

Technical Data

 

1.Cable Glands-Group ll.pdf

2.Hawke Accessories 2013 IDK.pdf

 

 

 

 

 

 

 

내 기술지원 및 구매상담처

CUSTOMER SUCCESS IDK

deric@jadongwha.com

www.tiatip.com

 

 

저작자 표시
신고
Posted by TIATIP

댓글을 달아주세요:: 네티켓은 기본, 스팸은 사절

호크 Hawke 501/414 Cable Gland 기술사양

 

안녕하세요 TIATIP 입니다.

 

오늘 이 시간에는 Conduit System 관련 케이블글랜드인 501/414 Cable Gland를 살펴보도록 하겠습니다.

 

 

 

Hawke

Group II Hazardous Area

Flameproof Exd / Increased Safety Exe / Dust Extb

Dual Certified ATEX - IECEx

 

 

Application

Outdoor or indoor use.
For use with non-armoured elastomer and plastic insulated cables installed in conduit.

 

 

 

 

 

Features

Provides a cable retention seal onto the cables outer sheath.
When used in increased safety applications, this cable gland may be used with braided cable where the braid and the cables outer sheath pass into the enclosure. The braid must be suitably terminated into the enclosure.
Provides female running coupler for cable gland or conduit entry.

 

 

 

 

Materials & Finishes

The Hawke 501/414 cable gland is manufactured in Brass (standard), Nickel Plated Brass, 316 Stainless Steel or Aluminium. Brass NPT entries are nickel plated as standard.

 

 

 

 

Technical Data

1.Exd IIC Gb, Exe IIC Gb, Extb IIIC Db

2.Certificate No's. : Baseefa06ATEX0056X and IECEx BAS 06.0013X.

3.Suitable for use in: Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC.

4.Construction and Test Standards: IEC/EN 60079-0, IEC/EN 60079-1, IEC/EN 60079-7, IEC/EN 61241-0 and IEC/EN 61241-1.

5.Ingress Protection: IP66, IP67 and IP68 (30 metres for 7 days) to IEC/EN 60529 and NEMA 4X.

6.Deluge Protection to: DTS01

7.Operating Temperature Range: -60°C to +100°C

8.Assembly Instruction Sheet: AI 310.

 

 

Technical Data

501414 Spec IDK.pdf

501414 Assembly 01.pdf 

501414 Assembly 02.pdf

2.Hawke Accessories 2013 IDK.pdf

 

 

 

 

 

 

Ordering Format

[ Gland Type / Size / Male Thread / Female Thread / Options ]

Example without options : 501/414/C/M32/M32

Example with alternative seal option : 501/414/C/1-1/4"NPT/M32/S

501/414/Os/M20/M20

501/414/Os/1/2"MPT/M20

501/414/Os/1/2"MPT/1/2"NPT

501/414/O/M20/M20

501/414/O/1/2"NPT/M20

501/414/O/1/2"NPT/1/2"NPT

501/414/A/M20/M20

501/414/A/1/2"NPT/M20

501/414/A/1/2"NPT/1/2"NPT

501/414/A/3/4"NPT/M20

501/414/A/3/4"NPT/3/4"NPT

501/414/B/M25/M25

501/414/B/3/4"NPT/M25

501/414/B/3/4"NPT/3/4"NPT

501/414/B/1"NPT/M25

501/414/B/1"NPT/1"NPT

501/414/C/M32/M32

501/414/C/1"NPT/M32

501/414/C/1"NPT/1'NPT

501/414/C/1-1/4"NPT/M32

501/414/C/1-1/4"NPT/1-1/4"NPT

501/414/C2/M40/M40

501/414/C2/1-1/4"NPT/M40

501/414/C2/1-1/4"NPT/1-1/4'NPT

501/414/C2/1-1/2"NPT/M40

501/414/C2/1-1/2"NPT/1-1/2"NPT

501/414/D/M50/M50

501/414/D/1-1/2"NPT/M50

501/414/D/1-1/2"NPT/1-1/2"NPT

501/414/D/2"NPT/M50

501/414/D/2"NPT/2"NPT

501/414/E/M63/M63

501/414/E/2"NPT/M63

501/414/E/2"NPT/2'NPT

501/414/E/2-1/2"NPT/M63

501/414/E/2-1/2"NPT/2-1/2"NPT

501/414/F/M75/M75

501/414/F/2-1/2"NPT/M75

501/414/F/2-1/2"NPT/2-1/2"NPT

501/414/F/3"NPT/M75

501/414/F/3"NPT/3"NPT

 

 

 

 

 

 

 

내 기술지원 및 구매상담처

CUSTOMER SUCCESS IDK

deric@jadongwha.com

www.tiatip.com

 

 

저작자 표시
신고
Posted by TIATIP

댓글을 달아주세요:: 네티켓은 기본, 스팸은 사절

Hawke 501414 Cable Glands 제품사양

 

안녕하세요 TIATIP 입니다.

 

오늘은 Hawke 호크케이블그랜드 중에서 501414 타입을 살펴보도록 하겠습니다.

호크의 일반적인 케이블글랜드와는 달리 Conduit Entry 타입의 케이블글랜드 입니다.

 

 

 

Cable Glands
Hazardous Area
Flameproof Exd & Increased Safety Exe
Dual Certifi ed ATEX / IECEx

호크 501414 Cable Gland

 

 

 

 

호크 501/414 Cable Gland 시리즈

 

 

501/414 시리즈의  ISO Metric Thread 타입과 NPT 타입을 각각 다음과 같이 나누어 볼 수 있으며 각각의 Thread타입은 Cable의 Outer sheath의 Min.~Max. 범위별 Size 참조(Os, O, A, B, C, C2, D, E, F)로 구분됩니다.

 

일반적인 표준사양인 Brass재질의 궁성이며, Nickel Plated Brass는 품번 끝에 별도표기를 하시면 됩니다.

 

501/414의 고유특성상 Male Entry Thread Size와 Female Entry Thread Size를 상세하게 표기하는 방법으로 품번오류를 최소화할 수 있겠습니다.

 

501/414/Os/M20(Male)xM20(Female)

501/414/O/M20(Male)xM20(Female)

501/414/A/M20(Male)xM20(Female)

501/414/B/M25(Male)xM25(Female)

501/414/C/M32(Male)xM32(Female)

501/414/C2/M40(Male)xM40(Female)

501/414/D/M50(Male)xM50(Female)

501/414/E/M63(Male)xM63(Female)

501/414/F/M75(Male)xM75(Female)

 

501/414/Os/1/2"NPT(Male)x1/2"NPT(Female)

501/414/O/1/2"NPT(Male)x1/2"NPT(Female)

501/414/A/3/4"NPT(Male)x3/4"NPT(Female)

501/414/A/1/2"NPT(Male)x1/2"NPT(Female)

501/414/B/1"NPT(Male)x1"NPT(Female)

501/414/B/3/4"NPT(Male)x3/4"NPT(Female)

501/414/C/1-1/4"NPT(Male)x1-1/4"NPT(Female)

501/414/C/1"NPT(Male)x1"NPT(Female)

501/414/C2/1-1/2"NPT(Male)x1-1/2"NPT(Female)

501/414/C2/1-1/4"NPT(Male)x1-1/4"NPT(Female)

501/414/D/2"NPT(Male)x2"NPT(Female)

501/414/D/1-1/2"NPT(Male)x1-1/2"NPT(Female)

501/414/E/2-1/2"NPT(Male)x2-1/2"NPT(Female)

501/414/E/2"NPT(Male)x2"NPT(Female)

501/414/F/3"NPT(Male)x3"NPT(Female)

501/414/F/2-1/2"NPT(Male)x2-1/2"NPT(Female)

 

 

Application

• Outdoor or indoor use.

• For use with non-armoured elastomer and plastic insulated cables installed
  in conduit.

• See technical section for installation rules and regulations.

 

 

 

Features

Provides a cable retention seal onto the cables outer sheath.
When used in increased safety applications, this cable gland may be used with braided cable where the braid and the cables outer sheath pass into the enclosure.

The braid must be suitably terminated into the enclosure.
•  Provides female running coupler for cable gland or conduit entry.

•  The 501/414 cable gland is manufactured in Brass (standard), Nickel Plated  

   Brass, 316 Stainless Steel or Aluminium.
•  Brass NPT entries are nickel plated as standard.

 

 

악세서리

 

 

Technical Data

Exd IIC Gb, Exe IIC Gb, Extb IIIC Db
Baseefa Certificate No. Baseefa06ATEX0056X.
IECEx Certificate No. IECEx BAS 06.0013X.
Suitable for use in Zone 1, Zone 2, Zone 21 and Zone 22.
Suitable for use in Gas Groups IIA, IIB and IIC.
Construction and Test Standards: IEC/EN 60079-0, IEC/EN 60079-1, IEC/EN

   60079-7, IEC/EN 61241-0 and IEC/EN 61241-1.
Ingress Protection: IP66, IP67 and IP 68 (30 metres for 7 days) to IEC/EN 60529

   and NEMA 4X.
Deluge protection to DTS01.
Operating Temperature Range: -60°C to +100°C.

 

상세사양은 첨부파일을 참고하여 주시기 바랍니다.

 

Hawke 호크 501414 01.pdf

Hawke 호크 Accessories 01.pdf

Hawke 호크 501414 조립도 01.pdf

 

 

 

국내 기술지원 및 상담구매처

CUSTOMER SUCCESS IDK

deric@jadongwha.com

www.tiatip.com

 

 

저작자 표시
신고
Posted by TIATIP

댓글을 달아주세요:: 네티켓은 기본, 스팸은 사절


BLOG main image
by TIATIP

카테고리

TI Story (949)
TIA (92)
TIP (194)
TIEx (593)
TIS (36)
TIO (23)
TiNoTe (10)
The OtherS (1)