호크 Hawke Group II Cable Gland Range 라인업소개

 

안녕하세요 TIATIP 입니다.

 

육상 및 해상플랜트 등 방폭위험지역에 주로 적용되는 Hawke Group II Cabel Gland Range 라인업을 소개드립니다. 

 

 

 

 

Hawke

Group II Cable Gland Range

For harsh and hazardous locations

 

 

What is a hazardous area cable gland?

 

Cable glands are designed to terminate cables into flameproof or increased safety equipment in hazardous areas. They provide a weather and gas-proof sealed connection between cable and equipment, prevent the cable being pulled out or twisted and provide a grounding of the cable armour.

 

 

 

 

The cost of a cable gland is insignificant when compared to that of other equipment. However, the cost of failure is high.

 

Though some cable glands may be "fit for purpose" what would be the potential cost of failure?

 

 

1. Hawke 501/421 Cable Gland

 

Exd IIC Gb, Exe IIC Gb, Extb IIIC Db

Non-armoured
ATEX IECEx Approved

 

 

 

 

2. Hawke 501/423 Cable Gland

 

Exd IIC Gb, Exe IIC Gb, Extb IIIC Db

Non-armoured
ATEX IECEx Approved

 

 

 

 

3. Hawke 501/453/RAC Cable Gland

 

Exd IIC Gb, Exe IIC Gb, Extb IIIC Db

Non-armoured
ATEX IECEx Approved

 

 

 

 

4. Hawke 501/453/RAC/L Cable Gland

 

Exd IIC Gb, Exe IIC Gb, Extb IIIC Db

Non-armoured
ATEX IECEx Approved

 

 

 

 

5. Hawke 501/453/Universal Cable Gland

 

Exd IIC Gb, Exe IIC Gb, ExnR IIC Gc, Extb IIIC Db

Armoured
ATEX IECEx Approved

 

 

 

 

6. Hawke PSG 553/RAC Cable Gland

 

Exe IIC, Exd IIC, Extb IIIC

Armoured
ATEX IECEx Approved

 

 

 

 

7. Hawke ICG/623 Cable Gland

 

Exd IIC Gb, Exe IIC Gb, Extb IIIC Db

Non-Armoured
ATEX IECEx Approved

 

 

 

 

8. Hawke ICG 653/Universal Cable Gland

 

Exd IIC Gb, Exe II Gb, Extb IIIC Db

Armoured
ATEX IECEx Approved

 

 

 

 

 

9. Hawke ICG 653/Universal/L Cable Gland

 

Exd IIC Gb, Exe II Gb, Extb IIIC Db

Armoured
ATEX IECEx Approved

 

 

 

 

10. Hawke 501/414 Cable Gland

 

Exd IIC Gb, Exe IIC Gb, Extb IIIC Db

Non-armoured
ATEX IECEx Approved

 

 

 

 

11. Hawke SB 474 Cable Gland

 

Exd IIC Gb, Exe IIC Gb, Extb IIIC Db

Non-armoured
ATEX IECEx Approved

 

 

 

 

 

12. Hawke CSB 656N Cable Gland

 

Exd IIC Gb, Exe IIC Gb, Extb IIIC Db

Non-armoured
ATEX IECEx Approved

 

 

 

 

Hawke Thread Conversion Solutions and Accessories

 

 

 

 

Hawke Thread Conversion Solutions and Accessories

 

 

 

Technical Data

 

1.Cable Glands-Group ll.pdf

2.Hawke Accessories 2013 IDK.pdf

 

 

 

 

 

 

 

내 기술지원 및 구매상담처

CUSTOMER SUCCESS IDK

deric@jadongwha.com

www.tiatip.com

 

 

저작자 표시
신고
Posted by TIATIP

댓글을 달아주세요:: 네티켓은 기본, 스팸은 사절

호크 Hawke CSB 656N Cable Gland 기술사양

 

안녕하세요 TIATIP 입니다.

 

Hawke Conduit System 의 CSB 656N Cable Gland 에 대해 살펴보도록 하겠습니다.

 

 

 

Hawke

Cable Glands

CSB 656N Cable Gland

Group II Hazardous Area

Flameproof Exd / Increased Safety Exe / Dust Extb /

Dual Certified ATEX - IECEx

 

 

 

 

 

 

 

Application

Outdoor or indoor use.
For use with conduit incorporating individual insulated conductors or for particular use with:-
a) Cables that are not effectively filled, compact and/or circular, have tape bedding or have hygroscopic fillers.
b) Cables that exhibit 'COLD FLOW' characteristics.
c) Enclosures containing an ignition source in gas group IIC areas or containing an ignition source in a Zone 1 area and exceeding 2 litres in volume.

 

 

 

 

 

Features

Provides a barrier seal between the individual insulated cores within the cable and prevents entry of the products of an explosion into the cable or conduit.
Seals conductors at entry to enclosure via conduit or enables an existing cable gland to be converted to a barrier type cable gland.
The device is fitted with a simple compound filled chamber which permits packing around individual insulated conductors. Assembly of the cable gland compresses and distributes the compound evenly to create a barrier seal at the point of entry into the enclosure. The compound chamber may be separated from the cured compound to ensure that the chamber has been effectively filled. If required, external voids can be repaired.
Provides female running coupler for cable gland or conduit entry.

 

 

 

 

 

 

Materials & Finishes

The CSB 656N cable gland is manufactured in Brass (standard), Nickel Plated Brass, 316 Stainless Steel or Aluminum. Brass NPT entries are nickel plated as standard.

 

Technical Data

1.Exd IIC Gb, Exe IIC Gb, Extb IIIC Db

2.Certificate No's Baseefa06ATEX0058X and IECEx BAS 06.0015X.

3.Suitable for use in: Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC.

4.Construction and Test Standards: IEC/EN 60079-0, IEC/EN 60079-1, IEC/EN 60079-7, IEC/EN 61241-0 and IEC/EN 61241-1.

5.Ingress Protection: IP66, IP67 and IP68 (30 metres for 7 days) to IEC/EN 60529 and NEMA 4X.

6.Deluge Protection to: DTS01

7.Operating Temperature Range: -60°C to +80°C

8.Assembly Instruction Sheet: AI 375.

 

CSB656N Spec.pdf

CSB656 Assembly.pdf

CSB656N Assembly.pdf

2.Hawke Accessories 2013 IDK.pdf

 

 

 

 

 

 

Hawke Ordering Format

[Gland Type/Size/Thread/Options]

Example : CSB 656N/C/M32/M32

 

 

 

  

 

 

내 기술지원 및 구매상담처

CUSTOMER SUCCESS IDK

deric@jadongwha.com

www.tiatip.com

 

저작자 표시
신고
Posted by TIATIP

댓글을 달아주세요:: 네티켓은 기본, 스팸은 사절

호크케이블글랜드 라인업과 다운로드링크

 

안녕하세요 TIATIP 입니다.

Hawke(호크) 케이블글랜드 관련 자료를 다운로드할 수 있는 사이트링크를 요약해 드립니다.

 

 

 

Our Cable Glands cover the whole spectrum of armoured and non-armoured cable and applications from general industrial through increased safety, deluge, flameproof and explosion proof. The Cable Glands are available in Brass as standard with Stainless Steel and Aluminium, as an optional material on certain designs. The innovative design features included in the range make our Cable Glands the lowest lifetime cost solution.

 

 

Hazardous Area Cable Glands

Features

  • 501/414
  • 501/421
  • 501/423
  • 501/453/RAC
  • 501/453/RAC/L
  • 501/453/Universal
  • CSB 656N
  • ICG 623
  • ICG 653/Universal
  • ICG 653/Universal/L
  • PSG 553/RAC
  • SB 474
  •  

     

    Group 1 Mining

    Features

  • 453/RAC
  • 453/T
  • 453/Universal
  • 623
  • 653/T
  • 653/Universal
  •  

     

     

    North American Series Cable Glands

    Features

  • 153/X
  • 701
  • 710
  • 711
  • 713
  • 753
  • 755
  •  

     

    Industrial Cable Glands

    Features

  • 114
  • 121 (Type A2)
  • 123 (Type A2)
  • 150/RAC (Type BW, BX and BZ)
  • 151/RAC (Type CW, CX and CZ)
  • 153/RAC (Type E1W, E1X and E1Z)
  • 153/RAC/L (Type E2W, E2X and E2Z)
  • 153/Universal (Type E1W, E1X and E1Z)
  •  

     

    Increased Safety Cable Glands

    321

     

     

     

     

     

     

     

     

     

     

     

    국내 기술지원 및 상담구매처

    CUSTOMER SUCCESS IDK

    deric@jadongwha.com

    www.tiatip.com

     

     

    저작자 표시
    신고
    Posted by TIATIP

    댓글을 달아주세요:: 네티켓은 기본, 스팸은 사절


    BLOG main image
    by TIATIP

    카테고리

    TI Story (949)N
    TIA (92)
    TIP (194)
    TIEx (593)N
    TIS (36)
    TIO (23)
    TiNoTe (10)
    The OtherS (1)