POCKER SWITCH for Harsh and Hazardous Environments

 

 

 

 

Features:
• Positive functions for ON and OFF to protect against accidental activation
• Luminous Strip for ease of sight
• 20A Contact Blocks
• For Wet Locations requiring Nema 4X or IP66
• Indoors or Outdoors in Class 1 Div 2 Harsh and Hazardous Locations
• IECEx and ATEX Certified, IP66 Ingress Protection
• Zone 1 & 2, Zone 21 & 22, Exde IIC Gb

 

 

 

 

Technical Data

킬락, 허벨, KILLARK, Hubbell, HAZCON, HKH Series, Rocker Switch, HKSRS, HKH1AND2RS4K8, HKH1ANDARS4, HKH1AND2RS1K8, HKH1ANDARS1, HKH1BND2RS4K8, HKH1BNDARS4, HKH1BND2RS1K8, HKH1BNDARS1

HKH RS Press Release 201608XX EN.pdf HKH RS Introduction Sheet 201608XX EN.pdf HKH RS BRO 201605XX EN.pdf

HKH RS Flyer 201608XX EN.pdf

2.Killark Controls IDK C.pdf

Note : Specifications are subject to change without notice.

소개된 제품 시스템의 사양, 재질, 치수, 기타 기재 내용은 제조공급사의 사정이나, 성능향상을 위해 예고 없이 단종, 대체되거나 변경되는 경우가 있으므로 양해를 부탁 드립니다. 기타 문의 상담은 하기 전문점을 통해 진행해 주시기 바랍니다. 

 

 

 

 

 

 

국내 상담문의 및 기술지원

CUSTOMER SUCCESS IDK

deric@jadongwha.com

www.tiatip.com

 

저작자 표시
신고
Posted by TIATIP

댓글을 달아주세요:: 네티켓은 기본, 스팸은 사절

KILLARK HKH Series HAZCON Controls 라인업 소개

 

안녕하세요 TIATIP 입니다.

오늘 이 시간에는 KILLARK에서 새롭게 출시된 킬락의 LCS(Local Control Station)/CS(Control Station) 제품군인 HKH Series 에 대해 살펴보도록 하겠습니다.

 

 

 

KILLARK

Controls

LCS(Local Control Stations), CS(Control Stations)

HKH Series

HAZCON

 

 

 

 

 

 

1. Non-Metallic DIN Rail Mount

 

 

 

Applications
• Hazardous and corrosive environments due to the presence of flammable gases or vapors, combustible dusts or ignitable fiber or flyings.
• Installations at petroleum refineries, chemical and petrochemical plants and
other processing or storage facilities where similar hazards exist.
• Use in conjunction with motor starters or contactors for remote control of motors.

 

Materials
• Impact Resistant Non-Metallic PA6 Glass Reinforced Antistatic Material
with f1 UV Protection against the most severe exposure to sunlight with a Flame
Retardant rating of V-0.
• Silicone gasketing on all enclosures and operators throughout.
• Brass gland plates available for metric size applications of plastic enclosures.

 

Features
• Size 1 Control Stations available as 1a, 1b, & 1c as standard catalog number
offerings for 1, 2 & 3 device openings and will accept 2-M20 entries in either
end. Ammeters available in 1b & 1c. Size 2 Enclosures available as 2a & 2c for 2, 4 & 6 device entries in cover with ability to accept 2-M25 entries in either end.
• Operating Temperature of -50ºC to +60ºC

• Explosion Protected contact blocks 690VAC N.O. & N.C. capable of 20 Amps for Switching Duty and HP Ratings up to 1HP.
• LED Pilot Light modules for 12-250V AC/DC for UL applications. 12-254V AC/DC for IEC applications.
• Contacts & Pilot lights can be mounted inside enclosure on Din Rail or in cover to the actuator.
• Accessories available for Lockout/Tag Out functions made in 316 stainless steel

 

 

2. Non-Metallic Panel Mount

 

 

 

 

Applications
• Hazardous and corrosive environments due to the presence of flammable gases or vapors, combustible dusts or ignitable fiber or flyings.
• Installations at petroleum refineries, chemical and petrochemical plants and
other processing or storage facilities where similar hazards exist.
• Use in conjunction with motor starters or contactors for remote control of motors.

 

Materials
• Impact Resistant Non-Metallic PA6 Glass Reinforced Antistatic Material
with f1 UV Protection against the most severe exposure to sunlight with a Flame
Retardant rating of V-0.

• Silicone gasketing on all enclosures and operators throughout.
• Brass gland plates available for metric size applications of plastic enclosures.

 

Features
• Size 1 Control Stations available as 1a, 1b, & 1c as standard catalog number
offerings for 1, 2 & 3 device openings and will accept 2-M20 entries in either
end. Ammeters available in 1b & 1c. Size 2 Enclosures available as 2a & 2c for 2, 4 & 6 device entries in cover with ability to accept 2-M25 entries in either end.

• Operating Temperature of -50ºC to +60ºC

• Explosion Protected contact blocks 690VAC N.O. & N.C. capable of 20 Amps for Switching Duty and HP Ratings up to 1HP.
• LED Pilot Light modules for 12-250V AC/DC for UL applications. 12-254V AC/DC for IEC applications.
• Contacts & Pilot lights can be mounted inside enclosure on Din Rail or in cover to the actuator.
• Accessories available for Lockout/Tag Out functions made in 316 stainless steel.

 

 

3. Stainless Steel DIN Rail Mount

 

 

 

 

 

 

Applications
• Hazardous and corrosive environments due to the presence of flammable gases or vapors, combustible dusts or ignitable fiber or flyings.
• Installations at petroleum refineries, chemical and petrochemical plants and
other processing or storage facilities where similar hazards exist.
• Use in conjunction with motor starters or contactors for remote control of motors.

 

Materials
• 316 Stainless Steel also available with a Standard internal flange and an external flange version when additional access is required.
• Silicone gasketing on all enclosures and operators through

 

Features
• Size 1 Control Stations available as 1a, 1b, & 1c as standard catalog number
offerings for 1, 2 & 3 device openings and will accept 2-M20 entries in either
end. Ammeters available in 1b & 1c. Size 2 Enclosures available as 2a & 2c for 2, 4 & 6 device entries in cover with ability to accept 2-M25 entries in either end.
• Operating Temperature of -50ºC to +60ºC
• Explosion Protected contact blocks 690VAC N.O. & N.C. capable of 20 Amps for Switching Duty and HP Ratings up to 1HP.
• LED Pilot Light modules for 12-250V AC/DC for UL applications. 12-254V AC/DC for IEC applications.
• Contacts & Pilot lights can be mounted inside enclosure on Din Rail or in cover to the actuator.
• Accessories available for Lockout/Tag Out functions made in 316 stainless stee

 

 

 

4. Stainless Steel Panel Mount

 

 

 

Applications
• Hazardous and corrosive environments due to the presence of flammable gases or vapors, combustible dusts or ignitable fiber or flyings.
• Installations at petroleum refineries, chemical and petrochemical plants and
other processing or storage facilities where similar hazards exist.
• Use in conjunction with motor starters or contactors for remote control of motors.

 

Materials
• 316 Stainless Steel also available with a Standard internal flange and an external flange version when additional access is required.
• Silicone gasketing on all enclosures and operators throughout.

 

 

Features
• Size 1 Control Stations available as 1a, 1b, & 1c as standard catalog number
offerings for 1, 2 & 3 device openings and will accept 2-M20 entries in either
end. Ammeters available in 1b & 1c. Size 2 Enclosures available as 2a & 2c for 2, 4 & 6 device entries in cover with ability to accept 2-M25 entries in either end.
• Operating Temperature of -50ºC to +60ºC
• Explosion Protected contact blocks 690VAC N.O. & N.C. capable of 20 Amps for Switching Duty and HP Ratings up to 1HP.
• LED Pilot Light modules for 12-250V AC/DC for UL applications. 12-254V AC/DC for IEC applications.
• Contacts & Pilot lights can be mounted inside enclosure on Din Rail or in cover to the actuator.
• Accessories available for Lockout/Tag Out functions made in 316 stainless steel.

 

 

 

 

CAT Number and Technical Data

HAZCON, LCS, Local Control Station, CS, Control Staton, KILLARK Controls, HKTF, HKH, HKH Series

 

Killark HKSB-HKH Antistatic Non-Metallic.pdf

Killark HKSB-HKH 316 Stainless Steel.pdf

 

주의사항 : 소개된 제품 시스템의 사양, 재질, 치수, 기타 기재 내용은 제조공급사의 사정이나, 성능향상을 위해 예고 없이 단종, 대체되거나 변경되는 경우가 있으므로 양해를 부탁 드립니다. 기타 문의 상담은 하기 전문점을 통해 진행해 주시기 바랍니다.

 

 

 

 

국내 상담문의 및 기술지원

CUSTOMER SUCCESS IDK

deric@jadongwha.com

www.tiatip.com

 

 

저작자 표시
신고
Posted by TIATIP

댓글을 달아주세요:: 네티켓은 기본, 스팸은 사절

KILLARK HKH Series HAZCON Controls 신제품 소개

 

안녕하세요 TIATIP 입니다.

오늘 이 시간에는 KILLARK에서 새롭게 준비한 Local Control Station, HKH Series에 대해 살펴보도록 하겠습니다.

 

 

 

 

HUBBELL KILLARK

HKH Series HAZCON Controls

for Harsh and Hazardous Environments

Local Control Stations

Control Solutions for Global Applications With GUAD Approvals

HKH Series Non-Metallic & Stainless Steel Control Stations

 

 

 

 

Applications
• Hazardous and corrosive environments due to the presence of flammable gases or vapors, combustible dusts or ignitable fiber or flyings.
• Installations at petroleum refineries, chemical and petrochemical plants and other processing or storage facilities where similar hazards exist.
• Use in conjunction with motor starters or contactors for remote control of motors.

 

 

 

 

Features
• Operating Temperature of -50°C to +60°C
• Explosion Protected contact blocks as N.O. & N.C. capable of 20 Amps for Switching Duty and HP Ratings up to 1HP.
• LED Pilot Light modules for 12-254V AC/DC
• Contacts & Pilot lights can be mounted inside enclosure on Din Rail or in cover to the actuator.
• Accessories for Lockout/Tag Out functions made in 316 stainless steel also available.
• Cover screws and terminal screws supplied for use with Slotted, Phillips #2 or Robertson screwdrivers.
• Captive Stainless Steel Cover Screws.
• Terminal Block connection option.

 

 

 

 

HKH Series Non-Metallic sizes
1a, 1b & 1c up to three devices in cover

 


• Low profile side walls for ease of wiring.
• Entry sizes of 1/2”, 3/4”, M20, M25 and 2 x M20. Brass ECP optional for metric sizes.


• Contact blocks 1 N.O. & 1 N.C. with 20A current capacity for switch duty.

• Contact blocks rated for up to 1HP @ 277V.

 


• LED Pilot lights 12-254Vac/Vdc for use with red, green, amber, blue & clear lens assemblies.
• Actuators and electrical modules can be mounted on din rail or panel mounted to actuator on cover.

• Terminals on contact blocks and pilot light modules rated for 1-2 #22-#10AWG, (1-2 0.5-4mm2) conductors.

 

 

HKH Series Non-Metallic sizes
2a & 2c from two to six devices in cover and entry sizes of 1/2”, 3/4”, M20, M25, M32, 2 x M20 or 2 M25. Side entries also available.

 

 

 

 

HKH Series 316 Stainless Steel sizes
1a, 1b & 1c up to three devices in cover


• Entry sizes of 1/2”, 3/4”, 1”, M20, M25 and 2 x M20.
• Two styles of enclosures offered; standard flange in, and when more access room required, flange out.

 

 


• Contact blocks 1 N.O. & 1 N.C. with 20A current capacity for switch duty.
• Contact blocks rated for up to 1HP @ 277V.
• LED Pilot lights 12-254Vac/Vdc for use with red, green, amber, blue & clear lens assemblies.

 

• Actuators and electrical modules can be mounted on din rail or panel mounted to actuator on cover.
• Terminals on contact blocks and pilot light modules rated for 1-2 #22-#10AWG, (1-2 0.5-4mm2) conductors.

 


HKH Series 316 Stainless Steel sizes
2a & 2c from two to six devices in cover and entry
sizes of 1/2”, 3/4”, 1” M20, M25, M32, 2 x M20 or 2 x M25. Side entries also available. Standard flange in & flange out design offered.

 

 

CAT Number and Technical Data

HAZCON, LCS, Local Control Station, Local Controls, KILLARK Controls, HKTF, HKH, HKH Series

 

KILLARK LCS HKTF HKH.pdf

 

주의사항 : 소개된 제품 시스템의 사양, 재질, 치수, 기타 기재 내용은 제조공급사의 사정이나, 성능향상을 위해 예고 없이 단종, 대체되거나 변경되는 경우가 있으므로 양해를 부탁 드립니다. 기타 문의 상담은 하기 전문점을 통해 진행해 주시기 바랍니다.

 

 

 

 

 

국내 상담문의 및 기술지원

CUSTOMER SUCCESS IDK

deric@jadongwha.com

www.tiatip.com

 

저작자 표시
신고
Posted by TIATIP

댓글을 달아주세요:: 네티켓은 기본, 스팸은 사절


BLOG main image
by TIATIP

카테고리

TI Story (947)
TIA (92)
TIP (194)
TIEx (591)
TIS (36)
TIO (23)
TiNoTe (10)
The OtherS (1)