호크 Hawke Group II Cable Gland Range 라인업소개

 

안녕하세요 TIATIP 입니다.

 

육상 및 해상플랜트 등 방폭위험지역에 주로 적용되는 Hawke Group II Cabel Gland Range 라인업을 소개드립니다. 

 

 

 

 

Hawke

Group II Cable Gland Range

For harsh and hazardous locations

 

 

What is a hazardous area cable gland?

 

Cable glands are designed to terminate cables into flameproof or increased safety equipment in hazardous areas. They provide a weather and gas-proof sealed connection between cable and equipment, prevent the cable being pulled out or twisted and provide a grounding of the cable armour.

 

 

 

 

The cost of a cable gland is insignificant when compared to that of other equipment. However, the cost of failure is high.

 

Though some cable glands may be "fit for purpose" what would be the potential cost of failure?

 

 

1. Hawke 501/421 Cable Gland

 

Exd IIC Gb, Exe IIC Gb, Extb IIIC Db

Non-armoured
ATEX IECEx Approved

 

 

 

 

2. Hawke 501/423 Cable Gland

 

Exd IIC Gb, Exe IIC Gb, Extb IIIC Db

Non-armoured
ATEX IECEx Approved

 

 

 

 

3. Hawke 501/453/RAC Cable Gland

 

Exd IIC Gb, Exe IIC Gb, Extb IIIC Db

Non-armoured
ATEX IECEx Approved

 

 

 

 

4. Hawke 501/453/RAC/L Cable Gland

 

Exd IIC Gb, Exe IIC Gb, Extb IIIC Db

Non-armoured
ATEX IECEx Approved

 

 

 

 

5. Hawke 501/453/Universal Cable Gland

 

Exd IIC Gb, Exe IIC Gb, ExnR IIC Gc, Extb IIIC Db

Armoured
ATEX IECEx Approved

 

 

 

 

6. Hawke PSG 553/RAC Cable Gland

 

Exe IIC, Exd IIC, Extb IIIC

Armoured
ATEX IECEx Approved

 

 

 

 

7. Hawke ICG/623 Cable Gland

 

Exd IIC Gb, Exe IIC Gb, Extb IIIC Db

Non-Armoured
ATEX IECEx Approved

 

 

 

 

8. Hawke ICG 653/Universal Cable Gland

 

Exd IIC Gb, Exe II Gb, Extb IIIC Db

Armoured
ATEX IECEx Approved

 

 

 

 

 

9. Hawke ICG 653/Universal/L Cable Gland

 

Exd IIC Gb, Exe II Gb, Extb IIIC Db

Armoured
ATEX IECEx Approved

 

 

 

 

10. Hawke 501/414 Cable Gland

 

Exd IIC Gb, Exe IIC Gb, Extb IIIC Db

Non-armoured
ATEX IECEx Approved

 

 

 

 

11. Hawke SB 474 Cable Gland

 

Exd IIC Gb, Exe IIC Gb, Extb IIIC Db

Non-armoured
ATEX IECEx Approved

 

 

 

 

 

12. Hawke CSB 656N Cable Gland

 

Exd IIC Gb, Exe IIC Gb, Extb IIIC Db

Non-armoured
ATEX IECEx Approved

 

 

 

 

Hawke Thread Conversion Solutions and Accessories

 

 

 

 

Hawke Thread Conversion Solutions and Accessories

 

 

 

Technical Data

 

1.Cable Glands-Group ll.pdf

2.Hawke Accessories 2013 IDK.pdf

 

 

 

 

 

 

 

내 기술지원 및 구매상담처

CUSTOMER SUCCESS IDK

deric@jadongwha.com

www.tiatip.com

 

 

저작자 표시
신고
Posted by TIATIP

댓글을 달아주세요:: 네티켓은 기본, 스팸은 사절

호크 Hawke PSG 553/RAC Cable Gland 기술사양

 

안녕하세요 TIATIP 입니다.

 

오늘은 호크 Hawke PSG 553/RAC Cable Gland 에 대하여 살펴보겠습니다.

 

 

Hawke

Cable Glands

PSG 553/RAC Cable Gland

Group II Hazardous A

Flameproof Exd / Increased Safety Exe / Dual Certified ATEX - IECEx

 

 

 

 

 

Application

Outdoor or indoor use.
For use with single wire armour ‘W’, wire braid ‘X’ and steel tape armour ‘Z’ elastomer and plastic insulated cables.
For particular use with:-
a) Cables that are not effectively filled, compact and/or circular, have tape bedding or have hygroscopic fillers.
b) Cables that exhibit 'cold flow' characteristics.
c) Enclosures for gas group IIC, under 2 litres in volume and containing an ignition source.
d) Enclosures for gas groups IIA or IIB, which are greater than 2 litres in volume and contain an ignition source.

 

 

 

 

 

Features

Provides a barrier seal to the individual insulated cores within the cable and prevents entry of the products of an explosion into the cable.
The required number of holes for the cores are punched in the seal by means of a special tool to suit the core size.
Provides armour clamping using one clamping arrangement for all armour/braid types.
Deluge protection option available contact Hawke Technical Sales for details.
Provides a cable retention and low smoke and fume, zero halogen seal onto the cables outer sheath.

 

 

 

 

 

Materials & Finishes

The PSG 553/RAC cable gland is manufactured in Brass (standard), Nickel Plated Brass, 316 Stainless Steel or Aluminium. Brass NPT entries are nickel plated as standard. 

 

Technical Data

1.Flameproof Exd and Increased Safety Exe ex logo II 2 GD ExtD A21.

2.Certificate No's Baseefa06ATEX0056X and IECEx BAS 06.0013X.

3.Suitable for use in: Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC.

4.Construction and Test Standards: IEC/EN 60079-0, IEC/EN 60079-1, IEC/EN 60079-7, IEC/EN 61241-0 and IEC/EN 61241-1.

5.Ingress Protection: IP66, IP67 and IP68 (30 metres for 7 days) to IEC/EN 60529 and NEMA 4X.

6.Deluge Protection to: DTS01 (Deluge seal optional).

7.Operating Temperature Range: -60°C to +80°C

8.Assembly Instruction Sheet: AI 312.

 

 

PSG553RAC Spec.pdf

PSG553RAC Assembly 01.pdf

PSG553RAC Assembly 02.pdf

2.Hawke Accessories 2013 IDK.pdf

 

 

 

 

 

Hawke Ordering Format

[Gland Type/Size/Thread/Options]

Example : PSG 553/RAC/C/M32/Punch Tool No.1

 

 

 

 

 

 

 

 

 

내 기술지원 및 구매상담처

CUSTOMER SUCCESS IDK

deric@jadongwha.com

www.tiatip.com

 

 

저작자 표시
신고
Posted by TIATIP

댓글을 달아주세요:: 네티켓은 기본, 스팸은 사절

호크케이블글랜드 라인업과 다운로드링크

 

안녕하세요 TIATIP 입니다.

Hawke(호크) 케이블글랜드 관련 자료를 다운로드할 수 있는 사이트링크를 요약해 드립니다.

 

 

 

Our Cable Glands cover the whole spectrum of armoured and non-armoured cable and applications from general industrial through increased safety, deluge, flameproof and explosion proof. The Cable Glands are available in Brass as standard with Stainless Steel and Aluminium, as an optional material on certain designs. The innovative design features included in the range make our Cable Glands the lowest lifetime cost solution.

 

 

Hazardous Area Cable Glands

Features

  • 501/414
  • 501/421
  • 501/423
  • 501/453/RAC
  • 501/453/RAC/L
  • 501/453/Universal
  • CSB 656N
  • ICG 623
  • ICG 653/Universal
  • ICG 653/Universal/L
  • PSG 553/RAC
  • SB 474
  •  

     

    Group 1 Mining

    Features

  • 453/RAC
  • 453/T
  • 453/Universal
  • 623
  • 653/T
  • 653/Universal
  •  

     

     

    North American Series Cable Glands

    Features

  • 153/X
  • 701
  • 710
  • 711
  • 713
  • 753
  • 755
  •  

     

    Industrial Cable Glands

    Features

  • 114
  • 121 (Type A2)
  • 123 (Type A2)
  • 150/RAC (Type BW, BX and BZ)
  • 151/RAC (Type CW, CX and CZ)
  • 153/RAC (Type E1W, E1X and E1Z)
  • 153/RAC/L (Type E2W, E2X and E2Z)
  • 153/Universal (Type E1W, E1X and E1Z)
  •  

     

    Increased Safety Cable Glands

    321

     

     

     

     

     

     

     

     

     

     

     

    국내 기술지원 및 상담구매처

    CUSTOMER SUCCESS IDK

    deric@jadongwha.com

    www.tiatip.com

     

     

    저작자 표시
    신고
    Posted by TIATIP

    댓글을 달아주세요:: 네티켓은 기본, 스팸은 사절


    BLOG main image
    by TIATIP

    카테고리

    TI Story (957)
    TIA (92)
    TIP (194)
    TIEx (601)
    TIS (36)
    TIO (23)
    TiNoTe (10)
    The OtherS (1)