호크 Hawke Stopping Plug Range

 

안녕하세요 TIATIP 입니다.

 

오늘은 호크 Hawke 악세서리 가운데, Stopping Plug의 종류에 대해 살펴보도록 하겠습니다.

 

 

 

 

Hawke

Stopping Plug Range

Connection Solutions for Global Applications

Provides a means of sealing and stopping unused threaded entries in enclosures where the certification requires the use of stopping plugs.

 

 

1. 375 Domed Head Stopping Plug

 

Exe IIC / Extb IIIC

 

 

 

 

2. 387 Domed Head Stopping Plug

 

Exe Ex II 2 GD IP66

 

 

 

 

3. 390 Hexagon Head Stopping Plug

 

Exe I / Exe IIC / Extb IIIC

 

 

 

 

4. 475 Tamperproof Stopping Plug

 

Exd II C / Exd I

 

 

 

 

5. 477 Tamperproof Stopping Plug

 

Exd IIC / Exd I

 

 

 

 

6. 487 Domed Head Stopping Plug

 

Exe I / Exd I / Exe IIC / Exd IIC / Extb IIIC

 

 

 

 

 

7. Others

 

 

 

 

 

 

Technical Data

2.Hawke Accessories 2013 IDK.pdf 

1.Hawke Accessories 2012 IDK.pdf

 

 

 

 

 

 

 

 

 

 

내 기술지원 및 구매상담처

CUSTOMER SUCCESS IDK

deric@jadongwha.com

www.tiatip.com

 

저작자 표시
신고
Posted by TIATIP

댓글을 달아주세요:: 네티켓은 기본, 스팸은 사절

호크 Hawke  375 Domed Head Stopping Plug 기술사양

 

안녕하세요 TIATIP 입니다.

 

오늘은 Hawke Stopping Plug 라인업 가운데, Domed Head  타입의 375 Series를 살펴보겠습니다.

 

 

 

 

 

 

 

 

 

Hawke

Accessories

375 Domed Head Stopping Plug

Increased Safety Exe / Dual Certified ATEX - IECEx

 

 

 

 

 

 

 

 

General Information

M16 to M75 as standard.
Thread length is 15mm as standard.
Metric entry threads are 1.5mm pitch as standard.

 

 

 

 

 

 

Materials & Finishes

Manufactured in Polyamide with Nitrile O-Ring.

 

 

 

 

 

 

Technical Data

1.Increased Safety Exe IIC Gb, Extb IIIC Db, ex logo II 2GD

2.Certificate No's Pending

3.Suitable for use in: Zone 1, Zone 2, Zone 21 and Zone 22.

4.Construction and Test Standards: IEC/EN 60079-0, IEC/EN 60079-7 and IEC/EN 60079-31.

5.Ingress Protection: IP66.

6.Operating Temperature Range: -60°C to +75°C

7.Group II and III.

  

375 Spec 1.pdf

375 Spec 2.pdf

375 Assembly 1.pdf

375 Assembly 2.pdf

2.Hawke Accessories 2013 IDK.pdf

 

 

 

 

 

Hawke Ordering Format [Product/Thread Size/Material/Finish]

Example :

375/M16

375/M20

375/M25

375/M32

375/M40

375/M50

375/M63

375/M75

 

 

 

 

 

 

 

 

내 기술지원 및 구매상담처

CUSTOMER SUCCESS IDK

deric@jadongwha.com

www.tiatip.com

 

 

저작자 표시
신고
Posted by TIATIP

댓글을 달아주세요:: 네티켓은 기본, 스팸은 사절

호크 Hawke 390 Hexagon Head Stopping Plug 기술사양

 

안녕하세요 TIATIP 입니다.

 

오늘은 Hawke Stopping Plug 라인업 가운데, Hexagon Head  타입의 390 Series를 살펴보겠습니다.

 

 

 

 

 

 

 

Hawke

Accessories

390 Hexagon Head Stopping Plug

Increased Safety Exe / Dual Certified ATEX - IECEx

 

 

 

 

 

 

General Information

M16 to M130 as standard.
M16 to M75 are 1.5mm pitch as standard.
M80 to M130 are 2.0mm pitch as standard (20mm thread length).
Other parallel thread options available on request, including BSPP, PG, ET and NPSM. NPT threads also available.

 

 

 

 

 

 

 

 

Materials & Finishes

Manufactured in Brass, Nickel Plated Brass, Steel, Nickel Plated Steel and Stainless Steel (Aluminium for Group II use only).

 

 

 

 

 

 

 

Technical Data

1.Increased Safety Exe I Mb, Exe IIC Gb, Extb IIIC Db, ex logo I M2/II 2GD.

2.Certificate No's Baseefa11ATEX0157X and IECEx BAS 11.0079X.

3.Suitable for use in:Zone 1, Zone 2, Zone 21, Zone 22 and mining applications.

4.Construction and Test Standards:IEC/EN 60079-0, IEC/EN 60079-7 and IEC/EN 60079-31.

5.Ingress Protection:IP66.

6.Operating Temperature Range: Nitrile ‘O’ Ring fitted as standard -60°C to +80°C
Silicone Option -60°C to +160°C.

7.Group I, II and III.

 

 

390 Spec.pdf

390 Assembly.pdf

2.Hawke Accessories 2013 IDK.pdf

 

 

  

 

 

 

Hawke Ordering Format [Product/Thread Size/Material/Finish]

Example :

390/M16/Brass

390/M20/Brass

390/M25/Brass

390/M32/Brass

390/M40/Brass

390/M50/Brass

390/M63/Brass

390/M75/Brass

390/1/2"NPT/Brass

390/3/4"NPT/Brass

390/1"NPT/Brass

390/1-1/4"NPT/Brass

390/1-1/2"NPT/Brass

390/2"NPT/Brass

390/2-1/2"NPT/Brass

390/3"NPT/Brass

390/3-1/2"NPT/Brass

390/M16/Brass/Nickel Plated

390/M20/Brass/Nickel Plated

390/M25/Brass/Nickel Plated

390/M32/Brass/Nickel Plated

390/M40/Brass/Nickel Plated

390/M50/Brass/Nickel Plated

390/M63/Brass/Nickel Plated

390/M75/Brass/Nickel Plated

390/1/2"NPT/Brass/Nickel Plated

390/3/4"NPT/Brass/Nickel Plated

390/1"NPT/Brass/Nickel Plated

390/1-1/4"NPT/Brass/Nickel Plated

390/1-1/2"NPT/Brass/Nickel Plated

390/2"NPT/Brass/Nickel Plated

390/2-1/2"NPT/Brass/Nickel Plated

390/3"NPT/Brass/Nickel Plated

390/3-1/2"NPT/Brass/Nickel Plated

 

 

 

 

 

 

 

내 기술지원 및 구매상담처

CUSTOMER SUCCESS IDK

deric@jadongwha.com

www.tiatip.com

 

 

 

저작자 표시
신고
Posted by TIATIP

댓글을 달아주세요:: 네티켓은 기본, 스팸은 사절

호크 Hawke 475 Tamperproof Stopping Plug 기술사양

 

안녕하세요 TIATIP 입니다.

 

오늘은 Hawke Stopping Plug 라인업 가운데, Tamperproof 타입의 475 Series를 살펴보겠습니다.

 

 

 

 

 

Hawke

Accessories

475 Tamperproof Stopping Plug

Flameproof Exd / Dual Certified ATEX - IECEx

 

 

 

 

General Information

The 475 is fitted from the outside of the enclosure.
M16 to M75 as standard.
Other thread options available on request, including BSPP, PG, NPT and ET.
Metric entry threads are 1.5mm pitch as standard.

 

 

 

 

 

 

Materials & Finishes

Manufactured in Brass, Nickel Plated Brass, Steel, Nickel Plated Steel and Stainless Steel. (Aluminium for Group II use only).

 

 

 

 

 

Technical Data

1.Flameproof Exd I Mb, Exd IIC Gb, Extb IIIC Db, ex logo IM2/II 2GD.

2.Certificate No's Baseefa10ATEX0262X and IECEx BAS 10.0120X.

3.Suitable for use in:
Zone 1, Zone 2, Zone 21, Zone 22 and mining applications.

4.Construction and Test Standards: IEC/EN 60079-0, IEC/EN 60079-1 and IEC/EN 60079-31.

5.Ingress Protection: IP66.

6.Operating Temperature Range: -60°C to +160°C.

7.Group I, II and III.

 

475 Spec 1.pdf

475 Spec 2.pdf

2.Hawke Accessories 2013 IDK.pdf

 

 

 

 

 

 

 

Hawke Ordering Format [Product/Thread Size/Material/Finish]

Example :

475/M16/Brass

475/M20/Brass

475/M25/Brass

475/M32/Brass

475/M40/Brass

475/M50/Brass

475/M63/Brass

475/M75/Brass

475/1/2"NPT/Brass

475/3/4"NPT/Brass

475/1"NPT/Brass

475/1-1/4"NPT/Brass

475/1-1/2"NPT/Brass

475/2"NPT/Brass

475/2-1/2"NPT/Brass

475/3"NPT/Brass

475/3-1/2"NPT/Brass

475/M16/Brass/Nickel Plated

475/M20/Brass/Nickel Plated

475/M25/Brass/Nickel Plated

475/M32/Brass/Nickel Plated

475/M40/Brass/Nickel Plated

475/M50/Brass/Nickel Plated

475/M63/Brass/Nickel Plated

475/M75/Brass/Nickel Plated

475/1/2"NPT/Brass/Nickel Plated

475/3/4"NPT/Brass/Nickel Plated

475/1"NPT/Brass/Nickel Plated

475/1-1/4"NPT/Brass/Nickel Plated

475/1-1/2"NPT/Brass/Nickel Plated

475/2"NPT/Brass/Nickel Plated

475/2-1/2"NPT/Brass/Nickel Plated

475/3"NPT/Brass/Nickel Plated

475/3-1/2"NPT/Brass/Nickel Plated

 

 

 

 

 

 

 

 

내 기술지원 및 구매상담처

CUSTOMER SUCCESS IDK

deric@jadongwha.com

www.tiatip.com

 

 

저작자 표시
신고
Posted by TIATIP

댓글을 달아주세요:: 네티켓은 기본, 스팸은 사절

호크 Hawke 477 Tamperproof Stopping Plug 기술사양

 

안녕하세요 TIATIP 입니다.

 

오늘은 Hawke Stopping Plug 라인업 가운데, Tamperproof 타입의 477 Series를 살펴보겠습니다.

 

 

 

Hawke

Accessories

477 Tamperproof Stopping Plug

Flameproof Exd / Dual Certified ATEX - IECEx

 

General Information

The 477 is fitted from the inside of the enclosure.
M16 to M75 as standard.
Other thread options available on request, including BSPP, PG, NPT and ET.
Metric entry threads are 1.5mm pitch as standard.

 

 

 

 

Materials & Finishes

Manufactured in Brass, Nickel Plated Brass, Steel, Nickel Plated Steel and Stainless Steel. (Aluminium for Group II use only).

 

 

 

Technical Data

1.Flameproof Exd IM2, Exd IIC Gb, Extb IIIC Db, ex logo IM2 II 2GD.

2.Certificate No's Baseefa10ATEX0262X and IECEx BAS 10.0120X.

3.Suitable for use in:Zone 1, Zone 2, Zone 21, Zone 22 and mining applications.

4.Construction and Test Standards:IEC/EN 60079-0, IEC/EN 60079-1 and IEC/EN 60079-31.

5.Ingress Protection:IP66.

6.Operating Temperature Range:-60°C to +160°C.

7.Group I, II and III.

 

 

477 Spec.pdf

477 Assembly.pdf

2.Hawke Accessories 2013 IDK.pdf

 

 

 

 

Hawke Ordering Format [Product/Thread Size/Material/Finish]

Example :

477/M16/Brass/Nickel Plated

477/M20/Brass/Nickel Plated

477/M25/Brass/Nickel Plated

477/M32/Brass/Nickel Plated

477/M40/Brass/Nickel Plated

477/M50/Brass/Nickel Plated

477/M63/Brass/Nickel Plated

477/M75/Brass/Nickel Plated

477/1/2"NPT/Brass/Nickel Plated

477/3/4"NPT/Brass/Nickel Plated

477/1"NPT/Brass/Nickel Plated

477/1-1/4"NPT/Brass/Nickel Plated

477/1-1/2"NPT/Brass/Nickel Plated

477/2"NPT/Brass/Nickel Plated

477/2-1/2"NPT/Brass/Nickel Plated

477/3"NPT/Brass/Nickel Plated

477/3-1/2"NPT/Brass/Nickel Plated

 

 

 

 

 

 

 

 

내 기술지원 및 구매상담처

CUSTOMER SUCCESS IDK

deric@jadongwha.com

www.tiatip.com

 

 

 

저작자 표시
신고
Posted by TIATIP

댓글을 달아주세요:: 네티켓은 기본, 스팸은 사절

호크 Hawke 487 Domed Head Stopping Plug 기술사양

 

안녕하세요  TIATIP 입니다.

 

 

 

General Information

M16 to M130 as standard.
Other parallel thread options available on request, including BSPP, PG, NPSM and ET. NPT available as 387 Exe Plug.
Metric entry threads are 1.5mm pitch as standard.

 

 

 

Materials & Finishes

Manufactured in Brass, Nickel Plated Brass, Steel, Nickel Plated Steel and Stainless Steel. (Aluminium for Group II use only).

 

 

 

Technical Data

1.Increased Safety and Flameproof Exe I Mb, Exd I Mb, Exe IIC Gb, Exd IIC Gb, Extb IIIC Db, ex logo IM2 / II 2GD.

2.Certificate No's Baseefa11ATEX0149X and IECEx BAS 11.0071X.

3.Suitable for use in: Zone 1, Zone 2, Zone 21, Zone 22 and mining applications.

4.Construction and Test Standards: IEC/EN 60079-0, IEC/EN 60079-1, IEC/EN 60079-7 and IEC/EN 60079-31.

5.Ingress Protection:
IP66.

6.Operating Temperature Range: Nitrile ‘O’ Ring fitted as standard -60°C to +80°C. Silicone Option -60°C to +160°C. Group I, II and III.

 

 

 

 

 

 

Technical Document

487 Spec.pdf

487 Assembly.pdf

2.Hawke Accessories 2013 IDK.pdf

 

 

 

 

 

 

내 기술지원 및 구매상담처

CUSTOMER SUCCESS IDK

deric@jadongwha.com

www.tiatip.com

 

저작자 표시
신고
Posted by TIATIP

댓글을 달아주세요:: 네티켓은 기본, 스팸은 사절

호크 Hawke 387 Domed Head Stopping Plug 기술사양

 

안녕하세요 TIATIP 입니다.

 

 

 

Hawke

Increased Safety Exe

Accessories for Junction boxes/Enclosures

 

 

 

 

 

Application

To close unused cable gland entries and maintain the integrity of the equipment.

 


Materials & Finishes

387 Stopping Plugs are manufactured in Brass (standard), Nickel Plated Brass or 316 Stainless Steel.

 

 

 

 

 

Technical Data

1.Increased Safety Exe ex logo II 2 GD IP66

2.Certificate No's Baseefa06ATEX0118U and IECEx BAS06.0029U

3.Construction and Test Standards: IEC/EN 60079-0 and IEC/EN 60079-7.

4.Ingress Protection: To meet with IP66 and IP67, the stopping plugs must be fitted perpendicular to the equipment face in a suitably sized threaded or plain hole and the equipment face must be smooth. Plain holes must be no larger than 0.7mm above the major diameter of the stopping plug thread and the plug must be held in place with a lock nut. A serrated washer may also be fitted.

5.Operating Temperature Range:-20°C to +60°C

 

 

 

 

 

 

Technical Domument

387 Spec.pdf

387 Assembly.pdf

1.Hawke Accessories 2012 IDK.pdf

2.Hawke Accessories 2013 IDK.pdf

 

 

 

 

Hawke Ordering Format [Product/Thread Size/Material]

387/M16/Nickel Plated Brass

387/M20/Nickel Plated Brass

387/M25/Nickel Plated Brass

387/M32/Nickel Plated Brass

387/M40/Nickel Plated Brass

387/M50/Nickel Plated Brass

387/M63/Nickel Plated Brass

387/M75/Nickel Plated Brass

 

 

 

 

 

 

내 기술지원 및 구매상담처

CUSTOMER SUCCESS IDK

deric@jadongwha.com

www.tiatip.com

 

 

저작자 표시
신고
Posted by TIATIP

댓글을 달아주세요:: 네티켓은 기본, 스팸은 사절

OSCG, Ex Type, Stopping Plug, OSSP-H and OSSP-R

 

 

안녕하세요 TIATIP 입니다.

 

오늘 이 시간에는 대한민국 케이블글랜드 국가대표 OSCG(오에스씨지)의 제품군 가운데 Stopping Plug, OSSP-H and OSSP-R Type을 살펴보겠습니다.

 

Stopping Plug, OSSP-H and OSSP-R Type

 

 

OSSP-H 타입은 국내 현장에서 엔지니어분들이 선호하는 방식인 스패너등의 툴로 간단히 체결할 수 있으나, Cable Entry가 많은 배열에 있어서는 상호 Plug상에서 간섭으로 인해 스패너가 공간을 확보할 수 없어 체결에 어려움이 발생할 수 있습니다. 이처럼 Junction Boxes(Enclosures)의 Mount Plate의 Hole배열에 있어서 공간적인 제약이 따르는 곳에서는 OSSP-R타입을 설치하고 렌치 체결방식을 적용할 수 있습니다.

 

OSSP-H and OSSP-R Type

◎ Flameproof and Increased Safety

 

 

Application

◎ To close unused cable gland entries and maintain the flameproof and increased safety integrity of the equipment 

 

 

오에스씨지(OSCG), 스탑핑플럭, 블라인드플러그, Stopping Plug, Blind Plug 선정노하우

1. 나사산형식, Thread Type(Metric, NPT, PG 등)

2. 나사산크기, Thread Size(M16, M20, M32, M40, M50, M63, M75, M90, M100, 1/2", 3/4", 1", 1-1/4", 1-1/2", 2", 2-1/2", 3", 3-1/2", 4" 등)

3. 채결방식, Hexagon(스패너이용체결) or Round(렌치이용체결)

4. 재질, Material(Brass, Nickel Plated Brass, Stainless steel 등)

5. 필요수량, Quantity

6. 필요악세서리, Accessories(Locknut, Sealing Washer 등)

7. 품번선정예시

◎ OSCG, OSSP-H16, OSSP-R16, OSSP-H16-M16, OSSP-R16-M16

◎ OSCG, OSSP-H20, OSSP-R20, OSSP-H20-M20, OSSP-R20-M20, OSSP-H20-1/2"NPT, OSSP-R20-1/2"NPT

◎ OSCG, OSSP-H25, OSSP-R25, OSSP-H25-M25, OSSP-R25-M25, OSSP-H25-3/4"NPT, OSSP-R25-3/4"NPT

◎ OSCG, OSSP-H32, OSSP-R32, OSSP-H32-M32, OSSP-R32-M32, OSSP-H32-1"NPT, OSSP-R32-1"NPT

◎ OSCG, OSSP-H40, OSSP-R40, OSSP-H40-M40, OSSP-R40-M40, OSSP-H40-1.1/4"NPT, OSSP-R40-1.1/4"NPT

◎ OSCG, OSSP-H50, OSSP-R50, OSSP-H50-M50, OSSP-R50-M50, OSSP-H50-1.1/2"NPT, OSSP-R50-1.1/2"NPT

◎ OSCG, OSSP-H63, OSSP-R63, OSSP-H63-M63, OSSP-R63-M63, OSSP-H63-2"NPT, OSSP-R63-2"NPT

◎ OSCG, OSSP-H75, OSSP-R75, OSSP-H75-M75, OSSP-R75-M75, OSSP-H75-2.1/2"NPT, OSSP-R75-2.1/2"NPT

◎ OSCG, OSSP-H90, OSSP-R90, OSSP-H90-M90, OSSP-R90-M90, OSSP-H90-3"NPT, OSSP-R90-3"NPT

◎ OSCG, OSSP-H100, OSSP-R100, OSSP-H100-M100, OSSP-R100-M100, OSSP-H100-3.1/2"NPT, OSSP-R100-3.1/2"NPT

 

 

 

제품카탈로그(방폭환경)

OSCG Ex Type IDK Blue 2013V13.pdf

 

 

제품카탈로그(비방폭, 일반산업환경)     

OSCG Normal Type IDK Green 2013V13.pdf

 

 

저작자 표시
신고
Posted by TIATIP

댓글을 달아주세요:: 네티켓은 기본, 스팸은 사절

Hawke 375 Domed Head Stopping Plugs

 

안녕하세요 TIATIP 입니다.

 

Hawke의 Stopping Plug 가운데 375 시리즈를 살펴보겠습니다.

Provides a means of sealing and stopping unused threaded entries in enclosures where the certification requires the use of stopping plugs.

 

 

Certification Details

Increased Safety Exe IIC Gb, Extb IIIC Db,  II 2GD
Baseefa Certificate No. Baseefa12ATEX0095X.
IECEx Certificate No. IECEx BAS 12.0065X.
Operating Temperature Range -60°C to +75°C.
Group II and III.
Alternative certification options available:
 Certificate No. CEPEL 13.2206X.
 GOST R POCC GB 05 B03785.

 

General Information

Manufactured in Polyamide with Nitrile O-Ring.
M16 to M75 as standard.
Thread length is 15mm as standard.
Metric entry threads are 1.5mm pitch as standard.
Suitable for use in Zone 1, Zone 2, Zone 21 and Zone 22.
Construction and Test Standards: IEC/EN 60079-0, IEC/EN 60079-7 and IEC/EN 60079-31.
Ingress Protection: IP66.

 

 

주문품번의 예시

Hawke 375/ M16

Hawke 375/ M20

Hawke 375/ M32

Hawke 375/ M40

Hawke 375/ M50

Hawke 375/ M63

Hawke 375/ M75

Hawke 375/ 1/2"NPT 

Hawke 375/ 3/4"NPT 

Hawke 375/ 1"NPT 

Hawke 375/ 1-1/4"NPT 

Hawke 375/ 1-1/2"NPT 

Hawke 375/ 2"NPT 

Hawke 375/ 2-1/2"NPT 

Hawke 375/ 3"NPT 

 

* 참고 : 2013년 론칭시점에서는 Metric Thread 에 한하여 공급가능합니다.

NPT는 추후 계획일정시 다시 안내드리겠습니다.

Hawke Accessories for Cable Glands and Junction Boxes

 

 

Hawke Thread Conversion Solutions for Cable Glands and Junction Boxes

 

 

04_Hawke 375 IDK.pdf

Hawke 호크 Stopping plug 375 조립도 01.pdf

00.Hawke 호크 Accessories Old.pdf

00_Hawke 호크 Accessories New.pdf

 

 

 

 

내 기술지원 및 구매상담처

CUSTOMER SUCCESS IDK

deric@jadongwha.com

www.tiatip.com

 

 

저작자 표시
신고

'TIEx > HAWKE' 카테고리의 다른 글

Hawke 390 Hexagon Head Stopping Plug  (0) 2013.05.31
Hawke 387 Stopping Plug  (0) 2013.05.31
Hawke 375 Domed Head Stopping Plugs  (0) 2013.05.31
Hawke Locknuts  (0) 2013.05.31
Hawke Serrated Washers  (0) 2013.05.31
Hawke Red Fibre Washers  (0) 2013.05.31
Posted by TIATIP

댓글을 달아주세요:: 네티켓은 기본, 스팸은 사절

Hawke 호크 케이블글랜드의 최적선정을 위한 기준 10가지

 

안녕하세요 TIATIP 입니다.

 

오늘은 산업용 케이블글랜드의 선정에 필요한 내용으로는 무엇이 있는지 살펴보도록 하겠습니다. 기본적으로 다음의 10가지 사항에 대한 기본적인 컨셉으로 환경에 적합한 사양을 선정할 수 있겠습니다.

 

 

 

Hawke Cable Glands

 

 

1. 사용환경에 대한 정보확인

□비방폭용

□방폭용

   *Area : Zone0 Zone1 Zone2 

   *Gas : IIA IIB IIC

   *Enclosure Volume=2dm3(2Liter) 보다 크다/작다

  

     

2. 실제 고객사이트에서 요구되는 Standard & Certification

NEC (UL Others    ) 

IEC (CENELEC ATEX IECEx Bassefa Others     )

 

 

3. 케이블의 용도 (단순참고)

Power

Instrument

Control 

□기타

 

 

4. 케이블의 구조타입은 무엇인가

Non-armoured type        

Armoured type

   (Steel tape Single wire, SWA Wire braided MC Jacket Lead sheath  

    □기타 :   )

 

 

 

 

 

5. 케이블의 외경범위는  ( 케이블의 고유 오차범위를 고려할 것 )

Outer sheathe Min.(mm) :                              

Outer sheathe Max.(mm) :                          

 

 

6. Junction Box (단순참조)

   □방폭 등급 :

   □박스 사양 (Ex‘d’,  Ex‘e’,  □기타 방폭(          ),  □비방폭

   □박스 재질 :

   □박스 두께(mm) :

   □박스 Open size :

   □박스 나사산구조 :

 

 

Hawke Cable Gladns and Connectors for Junction boxes

 

Hawke Junction Boxes/Enclosures

 

 

7. Cable glands 의 재질(materials)

Brass     Nickel plated brass   Stainless steel (SUS :      )   Aluminium  

□ 기타 (                   )

 

 

8. Entry thread type and size

*Metric

Metric (M16, M20, M25, M32, M40, M50, M63, M75, M80, M90, M100)

 

*NPT

NPT (1/2”, 3/4”, 1”, 1-1/4”, 1-1/2”, 2”, 2-1/2”, 3”, 3/1/2”, 4”       □기타(                  )

 

 

9. Technical Option

Compression (Single, Double)

Cold Flow characteristics

Deluge (DTS01) Ingress protection

Reversing Armour Clamp(RAC) clamping system

Compound barrier type

□ 기타 :

 

 

 

10. Hawke Accessories (해당 사이즈 및 재질 포함한 정보가 요구됩니다)

Sealing washer (Nylon, Red Fibre Washer)

Serrated washer               

Earth Tag

Locknut 

Shroud(LSFZH)

Stopping plug 

Adapter

Thread Conversion Item

□ 기타

 

 

 

 

 

 

 

 

 

내 기술지원 및 구매 상담처

CUSTOMER SUCCESS IDK

deric@jadongwha.com

www.tiatip.com


 

저작자 표시
신고
Posted by TIATIP

댓글을 달아주세요:: 네티켓은 기본, 스팸은 사절

Hawke Cable Glands 악세서리모음

 

안녕하세요 TIATIP 입니다.

 

오늘 이시간에는 앞서 살펴보았던 케이블그랜드에 추가로 검토되어야 하는 최적의 악세서리군을 소개하도록 하겠습니다. 각각의 사이트환경과 최종고객사와 EPC사등이 제안하는 RFQ등을 꼼꼼히 살펴보아야 하며, 특히 방폭규정과 국제표준에 위배되지 않는지 기술평가가 이루어져야 할 것입니다.

 

 

Adaptors And Reducers

 

Provides a means of attachment between dissimilar thread types or thread sizes.

 

  • Type 476 Adaptors And Reducers
  •  

     

     

     

  • Type 383 Earth Lead Adaptor
  •  

     

     

  • Type 479 Inline Adaptor (Male to Male)
  •  

     

     

     

  • Type 480 Inline Adaptor (Female to Female)
  •  

     

     

     

     

    Earth Tags

     

    Earthtags are installed between the cable gland and equipment to provide an earth/bond connection.

     

     

     

     

     

     

     

    Entry Thread Sealing Washers

     

    For use at the cable gland/enclosure interface to maintain the ingress protection rating of the equipment.

     

     

     

     

     

     

    Locknuts

     

    Locknuts are used to secure the cable gland body to the cable gland plate or the equipment.

     

     

     

     

     

     

    Stopping Plugs

     

    Provides a means of sealing and stopping unused threaded entries in enclosures where the certification requires the use of stopping plugs.

     

     

     

     

     

     

    Shrouds

     

    We offer a range of shrouds which are used to minimise the risk of dirt or foreign substances gathering on the cable gland body.

     

     

     

     

     

    Insulated Adaptors

     

    Provides electrical insulation between a cable gland or a conduit fitting and an electrical enclosure.

     

     

     

     

     

     

    Blanking/Adaptor Flanges

     

    To close unused cable gland entries and maintain the flameproof integrity of the equipment. To allow metric threaded group 1 cable gland types (653/Universal, 653/T, 623, 453/T, 453/Universal and 453/RAC) to be used in size up spigot entries.

     

     

     

     

    Breather Draining Devices

     

    Provides a method of preventing moisture build-up within a hazardous area approved enclosure whilst ensuring the integrity and Ex approval of the installation is maintained.

     

     

     

     

     

     

    In-Line Swivel Couplings

     

     

     

     

     

      

    Swivel Elbows

     

     

     

     

     

     

     

    Unions

     

    Type 481 (M to F) Union

     

     

     

     

     

    Type 482 (F to F) Union

     


     

     

    각 제품(악세서리)별 상세사양은 첨부파일을 참고하시기 바랍니다.

    2012년까지 제작된 버전과 새롭게 Hawke 전용라인을 통해 공급될 2013년이후 버전이 함께 사용될 수 있겠습니다.

     

     

     

     

    Hawke 호크 Accessories 01.pdf

    Hawke 호크 Thread Conversion 01.pdf

     

     

    국내 기술지원 및 상담구매처

    CUSTOMER SUCCESS IDK

    deric@jadongwha.com

    www.tiatip.com

     

     

    저작자 표시
    신고
    Posted by TIATIP

    댓글을 달아주세요:: 네티켓은 기본, 스팸은 사절


    BLOG main image
    by TIATIP

    카테고리

    TI Story (949)
    TIA (92)
    TIP (194)
    TIEx (593)
    TIS (36)
    TIO (23)
    TiNoTe (10)
    The OtherS (1)