'TIEx'에 해당되는 글 213건

  1. 2014.12.17 Chalmit ARRAN Exn LED Floodlight 기술사양
  2. 2014.12.17 Chalmit SCOTIAEx Exde LED Floodlight 기술사양
  3. 2014.11.12 T&B TnB Wiring Duct Cover TY3CPG6 사양소개
  4. 2014.11.12 T&B TnB Wiring Duct TY3X3WPG6 사양소개
  5. 2014.11.01 Chalmit Lighting 샬밋라이팅 Industrial Sterling II HF Stainless Steel Surface Mounted Fluorescent 사양소개
  6. 2014.11.01 Chalmit Light 샬밋라이트 Industrial Fluorescent 제품라인업 소개
  7. 2014.11.01 Chalmit Light 샬밋라이트 Zone 2 Fluorescent 제품라인업 소개
  8. 2014.11.01 Chalmit Light 샬밋 Fluorescent 제품라인업 소개
  9. 2014.10.21 Chalmit 샬밋 458 EPDM Floodlight 기술사양
  10. 2014.10.10 Chalmit 샬밋 비방폭 일반산업형 Bulkhead 라인업 소개
  11. 2014.10.10 Chalmit 샬밋 방폭위험지역 Zone2에 적용되는 Bulkhead 라인업 소개
  12. 2014.10.10 Chalmit 샬밋 방폭위험지역 Zone1에 적용되는 Bulkhead 라인업 소개
  13. 2014.08.04 T&B, Liquidtight Flexible Cord & Cable Fittings, 2255 사양소개
  14. 2014.07.14 Ty-Met, Stainless steel, Releasable type cable tie, YRL-5-150-BC 제품소개
  15. 2014.07.10 Thomas&Betts(TnB,T&B), Manual Crimp Tool, ERG4001 사양소개
  16. 2014.07.08 KOPEX-EX Conduit System, Fitting Instructions for Non-Metallic Braided EXBQ 설치가이드
  17. 2014.07.08 KOPEX-EX Conduit System, Fitting Instructions for Non-Metallic EXPQ 설치가이드
  18. 2014.07.05 Hawke ATEX INLINE Connector, ControlEx Termination Hook up Procedure 자료
  19. 2014.07.05 Hawke Exd Connector, MK IV ControlEx 기술사양
  20. 2014.07.05 Hawke Exd Connector, InstrumEx 기술사양
  21. 2014.07.05 Hawke Live Demateable Connector, InstrumEx Termination Hook up Procedure 자료
  22. 2014.07.05 Hawke Power Connector, PowerEx Termination Hook up Procedure 자료
  23. 2014.07.05 Hawke Exd Connector, PowerEx 기술사양
  24. 2014.07.02 T&B, Type A-Non-Metallic Liquidtight Conduit & Fittings, 3721-TB
  25. 2014.06.23 T&B,TnB,Ty-Rap, Cable Tie TY27MFR 사양소개
  26. 2014.06.18 Hawke Thread Conversion Solutions Fixed Elbows 496(F to F) Series 기술사양 소개 (UPD20140531)
  27. 2014.06.18 Hawke Thread Conversion Solutions Fixed Elbows 495 (M to M) Series 기술사양 소개 (UPD20140531)
  28. 2014.06.18 Hawke Thread Conversion Solutions Fixed Elbows 494 Series 기술사양 소개 (UPD20140531)
  29. 2014.06.18 Hawke Cable Gland 321/R Series 기술사양 소개 (UPD20140611)
  30. 2014.06.18 Hawke Cable Gland 321 Series 기술사양 소개 (UPD20140611)

Chalmit ARRAN Exn LED Floodlight 기술사양

 

안녕하세요 TIATIP 입니다. 오늘 이 시간에는 Chalmit에서 새롭게 선보이는 LED Floodlight 인 ARRAN Series에 대해 함께 살펴보고자 합니다.

 

 

 

Chalmit Lighting

Exn LED Floodlighting

ARRAN

ATEX Category3

Zone2 & Zone22 Applications

 

 

 

The Arran LED floodlight range is low energy with an instant on output and 80,000 maintenance free hours to L70 (70% initial lumens). Specifically designed for applications where moisture, dirt or dust are present, the floodlight is highly vibration resistant and can be used in locations where flammable vapours, gases or combustible dusts exist.

 

 

Chalmit ARRAN Series - Technical Data & Std. Cat. No.

 

Arran LED Exn Zone2 201408XX.pdf

 

ARRN/06L/LE,ARRN/10L/LE,ARRN/11L/LE,ARRN/15L/LE

ARRN06LLE,ARRN10LLE,ARRN11LLE,ARRN15LLE

 

Notice : Specification are subject to change without notice.

주의사항 : 소개된 제품 시스템의 사양, 재질, 치수, 기타 기재 내용은 제조공급사의 사정이나, 성능향상을 위해 예고 없이 단종, 대체되거나 변경되는 경우가 있으므로 양해를 부탁 드립니다. 기타 문의 상담은 하기 전문대리점을 통해 진행해 주시기 바랍니다.

국내 상담문의 및 기술지원

CUSTOMER SUCCESS IDK

deric@jadongwha.com

www.tiatip.com

 

저작자 표시
신고
Posted by TIATIP

댓글을 달아주세요:: 네티켓은 기본, 스팸은 사절

Chalmit SCOTIAEx Exde LED Floodlight 기술사양

 

안녕하세요 TIATIP 입니다. 오늘 이 시간에는 2014년도 11월 Chalmit Lighting의 신제품 SCOTIAEx 사양에 대해 살펴보도록 하겠습니다. 기본적으로 Exde의 방폭형으로 LED방식이며 Floodlighting 타입입니다.

 

 

 

Chalmit Lighting

Floodlighting

Exde LED Floodlight

SCOTIAEx  - SCOD Series

Zone 1 & 21 Applications

ATEX Categrory2

 

 

The ScotiaEx LED Zone 1 floodlight range is low energy with an instant on output and 110,000 maintenance free hours. Specifically designed for applications where moisture, dirt or dust are present, the floodlight is highly vibration resistant and can be used in locations where flammable vapours, gases or combustible dusts exist.

 

 

 

Chalmit SCOTIAEx - Technical Data & Std. Cat. No.

 

SCOTIAEx Exde Zone1 201411XX.pdf

 

SCOD/07L/LE,SCOD/08L/LE,SCOD/11L/LE,SCOD/12L/LE

SCOD07LLE,SCOD08LLE,SCOD11LLE,SCOD12LLE

 

Notice : Specification are subject to change without notice.

주의사항 : 소개된 제품 시스템의 사양, 재질, 치수, 기타 기재 내용은 제조공급사의 사정이나, 성능향상을 위해 예고 없이 단종, 대체되거나 변경되는 경우가 있으므로 양해를 부탁 드립니다. 기타 문의 상담은 하기 전문대리점을 통해 진행해 주시기 바랍니다.

 

국내 상담문의 및 기술지원

CUSTOMER SUCCESS IDK

deric@jadongwha.com

www.tiatip.com

 

저작자 표시
신고
Posted by TIATIP

댓글을 달아주세요:: 네티켓은 기본, 스팸은 사절

T&B TnB Wiring Duct Cover TY3CPG6 사양소개

 

안녕하세요 TIATIP 입니다. 오늘 이 시간에는 Thomas&Betts 의 Wiring Duct Cover가운데 TY3CPG6 사양에 대해 살펴보도록 하겠습니다.

 

 

 

 

 

 

Thomas&Betts

T&B TnB Catalog Number : TY3CPG6

Wiring Duct Cover 

 

 

 

 

Features

- Wide fingers and slots increase rigidity and enable insertion of bundles. V-Shaped slot lead-in enables easier and faster wire installation. Rounded edges keep hands and wires free of abrasion.

- Non-slip cover does not slide easily and resists vibration. Flush cover attaches flush with sidewall for finished look.

- Dual score lines are designed to yield clean breakoffs at the base of the slot and the duct. Versatile North American and DIN Standard mounding holes enables same duct for multiple applications

 

 

 

 

Catalog Number must be completed by adding suffix G for Gray, W for White, B for Black, I for Intrinsic Blue. To order Adhesive-Backed duct, add suffix A. To order duct without mounting holes, add suffix NM to catalog number. Contact Customer Service for pricing and availability

 

 

 

 

Standard lengths are 6 feet

 

 

 

 

 

 

 

T&B TnB Wiring Duct Cover TY3CPG6 Technical Data

TY3CPG6.pdf

TnB Tyduct Overview.pdf

TnB Tyduct Specifications.pdf

TnB Tyduct Technical wideslot.pdf

TnB Tyduct Drawing.pdf

 

 

FYI : Specification are subject to change without notice.

소개된 제품 및 시스템의 사양, 재질, 치수, 기타 기재 내용은 제조공급사의 사정이나, 성능향상을 위해 예고 없이 단종, 대체되거나 변경되는 경우가 있으므로 양해해주시기 바랍니다. 기타 상세한 상담은 전문대리점을 통해 진행해 주시기 바랍니다. 고맙습니다.

 

 

 

 

  

국내 상담문의 및 기술지원

CUSTOMER  SUCCESS  IDK

deric@jadongwha.com

http://www.tiatip.com

 

저작자 표시
신고
Posted by TIATIP

댓글을 달아주세요:: 네티켓은 기본, 스팸은 사절

T&B TnB Wiring Duct TY3X3WPG6 사양소개

 

안녕하세요 TIATIP 입니다. 오늘 이 시간에는 Thomas&Betts 의 Wiring Duct 가운데 TY3X3WPG6 사양에 대해 살펴보도록 하겠습니다.

 

 

 

 

 

Thomas&Betts

T&B TnB Catalog Number : TY3X3WPG6

Wiring Duct

 

 

 

 

Features

- Wide fingers and slots increase rigidity and enable insertion of bundles. V-Shaped slot lead-in enables easier and faster wire installation. Rounded edges keep hands and wires free of abrasion.

- Non-slip cover does not slide easily and resists vibration. Flush cover attaches flush with sidewall for finished look.

- Dual score lines are designed to yield clean breakoffs at the base of the slot and the duct. Versatile North American and DIN Standard mounding holes enables same duct for multiple applications

 

 

 

 

 

Catalog Number must be completed by adding suffix G for Gray, W for White, B for Black, I for Intrinsic Blue. To order Adhesive-Backed duct, add suffix A. To order duct without mounting holes, add suffix NM to catalog number. Contact Customer Service for pricing and availability

 

 

 

 

Standard lengths are 6 feet

 

 

 

 

  

T&B TnB Wiring Duct TY3X3WPG6 Technical Data

TY3X3WPG6.pdf

TnB Tyduct Overview.pdf

TnB Tyduct Specifications.pdf

TnB Tyduct Technical wideslot.pdf

TnB Tyduct Drawing.pdf

 

 

FYI : Specification are subject to change without notice.

소개된 제품 및 시스템의 사양, 재질, 치수, 기타 기재 내용은 제조공급사의 사정이나, 성능향상을 위해 예고 없이 단종, 대체되거나 변경되는 경우가 있으므로 양해해주시기 바랍니다. 기타 상세한 상담은 전문대리점을 통해 진행해 주시기 바랍니다. 고맙습니다.

 

 

 

 

 

 

 

국내 상담문의 및 기술지원

CUSTOMER  SUCCESS  IDK

deric@jadongwha.com

http://www.tiatip.com

 

저작자 표시
신고
Posted by TIATIP

댓글을 달아주세요:: 네티켓은 기본, 스팸은 사절

Chalmit Lighting 샬밋라이팅 Industrial Sterling II HF Stainless Steel Surface Mounted Fluorescent 사양소개

 

안녕하세요 TIATIP 입니다.

오늘 이 시간에는 샬밋라이팅의 일반산업형 조명제품군 가운데 Chalmit Sterling II HF Stainless Steel Surface Mounted Fluorescent  사양에 대해 살펴보도록 하겠습니다.

   

 

Chalmit

Sterling II HF Stainless Steel

Surface Mounted Fluorscent 

  

 

 

 

The Sterling II High frequency luminaire is designed to provide a high quality, cost effective fluorescent luminaire for industrial areas, available in single and twin body versions. The construction features a marine grade 316S31 stainless steel body and transparent polycarbonate diffuser. These are secured using quick release stainless steel clips allowing easy access for rapid installation and maintenance.

The Sterling II H/F has a high frequency electronic control gear, available in 18W, 36W and 58W fluorescent lamp options.
 
Emergency models have an internal Ni-Cad battery. Please note that single lamp emergency versions are only supplied in a twin lamp body.

A version of the Sterling II is also available with a Copper & Iron ballast, please refer to the appropriate product page for details.
 

 

 

 

CAT Ref.

SS2I/118/BI,

SS2I/118/BI/EM

SS2I/118/EM/HF

SS2I/136/BI/HF

SS2I/136/BI/EM

SS2I/136/BI/EM/HF

SS2I/158/BI

SS2I/158/BI/EM

SS2I/158/BI/EM/HF

SS2I/218/BI

SS2I/218/BI/EM

SS2I/218/BI/EM/HF

SS2I/218/BI/HF

SS2I/236/BI

SS2I/236/BI/EM

SS2I/236/BI/EM/HF

SS2I/236/BI/HF

SS2I/258/BI

SS2I/258/BI/EM

SS2I/258/BI/EM/HF

SS2I/258/BI/HF

S3004-100001

S3004-100003

S3004-100004

SPOL4-100004

SPOL4-100005

SPOL4-100005

 

 

Technical Data

Sterling IISSHF Industrial.pdf

 

 

Notice : Specification are subject to change without notice.

주의사항 : 소개된 제품 및 시스템의 사양, 재질, 치수, 기타 기재 내용은 제조공급사의 사정이나, 성능향상을 위해 예고 없이 단종, 대체되거나 변경되는 경우가 있으므로 양해를 부탁 드립니다. 기타 문의 및 상담은 하기 전문대리점을 통해 진행해 주시기 바랍니다.   

 

 

 

 

  

 

국내 기술지원 및 구매상담처

CUSTOMER SUCCESS IDK

CS CENTER 010.5353.9110

deric@jadongwha.com

www.tiatip.com

 

저작자 표시
신고
Posted by TIATIP

댓글을 달아주세요:: 네티켓은 기본, 스팸은 사절

Chalmit Light 샬밋라이트 Industrial Fluorescent 제품라인업 소개

 

안녕하세요 TIATIP 입니다.

오늘 이 시간에는 Chalmit Light 샬밋조명가운데 일반산업환경에 적용가능한 Fluorescent 타입의 제품군에는 어떠한 것들이 있는지 대략 살펴보도록 하겠습니다.

 

(1) Chalmit Protecta Luminaire

Surface Mounted Fluorscent

The Protecta (Industrial) is a robust GRP fluorescent with high IP rating designed for use in the most arduous environments. It is constructed from the same GRP body design as the hazardous area versions. 
 
As such the industrial version features the Protecta's trademark quick-release GRP clamp bar which secures the hinged clear polycarbonate diffuser. This provides quick and easy access to the control gear.

All of the control gear is mounted on to the reflector/gear-tray which is fitted to the body. Ease of access to the lamps ensures that installation and maintenance times are kept to a minimum.

ATEX Categories 2 & 3 (Zones 1 & 2) hazardous area versions are available which are commonly used on Offshore Platforms, FPSO’s and FSO’s.

 

 

 

 

 

(2) Chalmit Protecta Emergency Luminaire

Surface Mounted Fluorescent

The Protecta (Industrial) is a robust GRP fluorescent with high IP rating designed for use in the most arduous environments. It is constructed from the same GRP body design as the hazardous area versions.

As such the industrial version features the Protecta's trademark quick-release GRP clamp bar which secures the hinged clear polycarbonate diffuser. This provides quick and easy access to the control gear.

All of the control gear is mounted on to the reflector/gear-tray which is fitted to the body. Ease of access to the lamps ensures that installation and maintenance times are kept to a minimum.

The Protecta Emergency comes complete with integral three hour Ni-Cd battery backup. The incoming mains supply to the luminaire has the facility for two live supplies: continuous live (Lc) which supplies constant power to the battery and switched live (Ls) which is for external switching, allowing the luminaire to be locally switched off without the emergency battery pack unintentionally operating the lamps.

If external switching is not required Lc and Ls are made common at the mains terminal block.

ATEX Categories 2 & 3 (Zones 1 & 2) hazardous area versions are available.

 

 

 

 

 

(3) Chalmit Protecta Stainless Steel Luminaire

Surface Mounted Fluorescent

The Protecta industrial fluorescent is available with a stainless steel body. Protecta has excellent durability as it is constructed using high grade 316S31 stainless steel and a polycarbonate diffuser. A standard non-emergency and emergency versions are available in both 18W and 36W lamp options.

The product is intended for industrial applications where chemical agents are present which could attack GRP bodied luminaires. The stainless steel enclosure affords a high degree of ingress protection(IP66/67). Its design also utilised the Protecta's key features providing ease of access to lamps and control gear. This ensures that installation and maintenance will be completed quickly and efficiently.

The Emergency version is also available complete with 3 hour Ni-Cad battery back-up.

 

 

 

 

 

(4) Chalmit Acclaim  Luminaire

Recessible Fluorescent

The Acclaim recessible lighting range is suitable for a range of industry standard ceiling types. Available as both emergency and non-emergency versions, the Acclaim can be used with 18W or 36W fluorescent lamps. The Acclaim has an IP ratnig of IP54 and is also certified to for use in fire resistant ceilings up to solas B15 rating.

 

The polycarbonate diffuser is avaiable in clear, prismatic or with a glare control louvre. The mounting and cover details are flexible to allow luminaires to be recessed. The control gear and batteries are mounted internally on a gear tray and access for lamp replacement and maintenance is simple and easy. The emergency version has excellent light output and duration in accordance with emergency lighting standards.

ATEX Category 2 (Zone 1) hazardous area versions are available.

 

 

 

 

 

(5) Chalmit Sterling II Luminaire

Surface Mounted Fluorescent

The Sterling II is designed to provide a high quality, cost effective fluorescent luminaire for industrial areas. It is available in single and twin body versions. The construction features a GRP body and polycarbonate diffuser. These are secured using quick release stainless steel clips allowing easy access for rapid installation and maintenance.

The Sterling II has a 230/240V 50Hz copper and iron ballast as standard, available in 18W, 36W and 58W fluorescent lamp options. Other supply voltage options are available.

Emergency models have an internal Ni-Cad battery.
Please note that single lamp emergency versions are only supplied in a twin lamp body.

A version of the Sterling II is also available with high frequency electronic ballast; please refer to the Sterling II HF product page for details.

 

 

 

 

 

(6) Chalmit Sterling II High Frequency Luminaire

Surface Mounted Fluorescent

The Sterling II High frequency luminaire is designed to provide a high quality, cost effective fluorescent luminaire for industrial areas. It is available in single and twin body versions. The construction features a GRP body and polycarbonate diffuser. These are secured using quick release stainless steel clips allowing easy access for rapid installation and maintenance.

The Sterling II H/F has a high frequency electronic ballast, available in 18W, 36W and 58W fluorescent lamp options.
 
Emergency models have an internal Ni-Cad battery. Please note that single lamp emergency versions are only supplied in a twin lamp body.

A version of the Sterling II is also available with a Copper & Iron ballast, please refer to the appropriate product page for details.

 

 

 

 

 

(7) Chalmit Sterling II Stainless Steel Luminaire

Surface Mounted Fluorescent

The Sterling II luminaire is designed to provide a high quality, cost effective fluorescent luminaire for industrial areas. It is available in single and twin body versions. The construction features a marine grade 316S31 stainless steel body and transparent polycarbonate diffuser. These are secured using quick release stainless steel clips allowing easy access for rapid installation and maintenance.

The Sterling II has a copper & iron switchstart ballast, available in 18W, 36W and 58W fluorescent lamp options.
 
Emergency models have an internal Ni-Cad battery. Please note that single lamp emergency versions are only supplied in a twin lamp body.

A version of the Sterling II is also available with a Highfrequency ballast (HF), please refer to the appropriate product page for details.

 

 

 

 

 

(8) Chalmit Curie Luminaire

Recessible Fluorescent

The Curie range of fluorescents is available in normal and emergency versions is designed purposely for use industrial applications where  recessible emergency lighting is required. The body is made from zinc coated sheet steel and the diffuser from prismatic polycarbonate with the textured side facing downwards. Where it meets the ceiling apeture the body is fitted with a flipper seal providing excellent sealing against surface irregularities.

The range is flexible to allow luminaires to be recessed into either plasterboard and modular (600x600mm & 600x1200mm) ceiling types. The control gear and batteries are mounted internally on a gear tray and access for lamp replacement and maintenance is simple and easy.

The emergency version has excellent emergency light output and duration in accordance with emergency lighting standards and comprehensice battery management & automatic self-testing is available as an option.

 

 

 

 

(9) Chalmit Sterling II HF Stainless Steel

Surface Mounted Fluorescent

The Sterling II High frequency luminaire is designed to provide a high quality, cost effective fluorescent luminaire for industrial areas, available in single and twin body versions. The construction features a marine grade 316S31 stainless steel body and transparent polycarbonate diffuser. These are secured using quick release stainless steel clips allowing easy access for rapid installation and maintenance.

The Sterling II H/F has a high frequency electronic control gear, available in 18W, 36W and 58W fluorescent lamp options.
 
Emergency models have an internal Ni-Cad battery. Please note that single lamp emergency versions are only supplied in a twin lamp body.

A version of the Sterling II is also available with a Copper & Iron ballast, please refer to the appropriate product page for details.

 

 

 

 

 

Technical Data

0.Chalmit Lighting Master CAT 20110611 02.pdf

 

 

Notice : Specification are subject to change without notice.

주의사항 : 소개된 제품 시스템의 사양, 재질, 치수, 기타 기재 내용은 제조공급사의 사정이나, 성능향상을 위해 예고 없이 단종, 대체되거나 변경되는 경우가 있으므로 양해를 부탁 드립니다. 기타 문의 상담은 하기 전문대리점을 통해 진행해 주시기 바랍니다.

 

 

 

 

국내 기술지원 및 구매상담

CUSTOMER SUCCESS IDK

CS CENTER 010.5353.9110

deric@jadongwha.com

www.tiatip.com

 

 

저작자 표시
신고
Posted by TIATIP

댓글을 달아주세요:: 네티켓은 기본, 스팸은 사절

Chalmit Light 샬밋라이트 Zone 2 Fluorescent 제품라인업 소개

 

안녕하세요 TIATIP 입니다.

오늘 이 시간에는 Chalmit Light 샬밋조명가운데 방폭위험지역 Zone 2에 적용가능한 Fluorescent 타입의 제품군에는 어떠한 것들이 있는지 대략 살펴보도록 하겠습니다.

 

(1) Chalmit Sterling II Luminaire

Ex n Fluorescent / ATEX Category 3

The Sterling II s a quality and cost effective luminaire designed to provide instant glare free white light for Zone 2 hazardous areas.

The GRP body and polycarbonate diffuser is secured with multiple stainless steel clips to ensure good corrosion resistance and allow rapid access for installation and maintenance. The protection is Ex n with IP65 sealing.

The Sterling II is designed as a single product for both Gas & Dust atmospheres and is certified under the ATEX 94-9-EC directive for Categories 3 G and 3 D. The range is also IECEx compliant.

The Sterling is suitable for T8 tubular fluorescent lamps in 18/36/58W sizes. Electronic high frequency control gear is fitted as standard.

 

 

 

 

 

(2) Chalmit Sterling II Emergency Luminaire

Ex n Fluorescent / ATEX Category 3

The Sterling II emergency fluorecent luminaire designed for Zone 2 areas with a 3 hour emergency duration. The GRP body and polycarbonate diffuser are secured with multiple stainless steel clips to ensure good corrosion resistance and allow rapid access for installation and maintenance.

The Sterling II is designed as a single product for both Gas & Dust atmospheres. It is certified with Ex n protection under the ATEX 94-9-EC directive for Categories 3 G and 3 D and has IP65 sealing. The range is also IECEx compliant.

The Sterling suitable for T8 tubular fluorescent lamps in 18/36/58W sizes. Electronic high frequency control gear is fitted as standard.

 

 

 

 

 

(3) Chalmit Sterling II Stainless Steel Luminaire

Ex n Fluorescent / ATEX Category 3

The Sterling II stainless is a robust, high quality luminaire designed for Zone 2 environments where there is a high risk of mechanical damage.
 
The stainless steel body and polycarbonate diffuser is secured using multiple stainless steel clips ensure excellent corrosion resistance and IP sealing. The quick release clips also provide rapid access for installation and maintenance.
 
The stainless steel body is designed to provide high impact strength and resistance to those chemicals which might damage GRP. The range is suitable for T8 tubular fluorescent lamps in the nominal 18/36/58W sizes. The standard range has electronic control gear and high frequency ballast.

 

 

 

 

 

(4) Chalmit Sterling II Emergency Stainless Steel Luminaire

Ex n Fluorescent / ATEX Category 3

The Sterling II stainless emergency is a robust, high quality luminaire designed for Zone 2 environments where there is a high risk of mechanical damage. The emergency version provides safety critical lighitng for three hours in the event of a mains power failure.
 
The stainless steel body and polycarbonate diffuser is secured using multiple stainless steel clips ensure excellent corrosion resistance and IP sealing. The quick release clips also provide rapid access for installation and maintenance.
 
The stainless steel body is designed to provide high impact strength and resistance to those chemicals which might damage GRP. The range is suitable for T8 tubular fluorescent lamps in the nominal 18/36/58W sizes. The standard range has electronic control gear.

 

 

 

 

 

(5) Chalmit Protecta II Luminaire

Ex n Fluorescent / ATEX Category 3

The Protecta Category 3 Ex n luminaire combines the strength and integrity of the Category 2 increased safety enclosure with the Category 3 lamp and control gear package used in the Sterling. The range is suitable for T8 tubular fluorescent lamps in the nominal 18W and 36W sizes.

Protecta is constructed using glass reinforced polyester (GRP) and polycarbonate which resist saline and other corrosive environments. A key feature is the Protecta's rugged duribility. This comes from strength of the enclosure combined with toughened mounting points together and the very high degree of ingress protection.
 
The Zone 2 luminaire certified Ex n with IP66/67 sealing for ignitable gas and dust applications. The ATEX Categories are 3 G and 3 D.

The simple design and ease of access to lamps and control gear means that installation and maintenance can be completed quickly and efficiently. The Protecta offers the facility of four cable entries. The standard range has electronic control gear and all
emergency versions come  complete with 3 hour battery duration.

 

 

 

Technical Data

0.Chalmit Lighting Master CAT 20110611 02.pdf

 

Notice : Specification are subject to change without notice.

주의사항 : 소개된 제품 시스템의 사양, 재질, 치수, 기타 기재 내용은 제조공급사의 사정이나, 성능향상을 위해 예고 없이 단종, 대체되거나 변경되는 경우가 있으므로 양해를 부탁 드립니다. 기타 문의 상담은 하기 전문대리점을 통해 진행해 주시기 바랍니다.

 

국내 기술지원 및 구매상담

CUSTOMER SUCCESS IDK

CS CENTER 010.5353.9110

deric@jadongwha.com

www.tiatip.com

 

 

저작자 표시
신고
Posted by TIATIP

댓글을 달아주세요:: 네티켓은 기본, 스팸은 사절

Chalmit Light 샬밋 Fluorescent 제품라인업 소개

 

안녕하세요 TIATIP 입니다.

오늘 이 시간에는 Chalmit Light 샬밋조명가운데 Fluorescent 타입의 제품군에는 어떠한 것들이 있는지 대략 살펴보도록 하겠습니다.

 

 

 

1. Zone 1

(1) Chalmit Protecta III Luminaire

Ex e Fluorescent / ATEX Category 2

 

 

 

(2) Chalmit Protecta III Emergency Luminaire

Ex e Fluorescent / ATEX Category 2

 

 

 

(3) Chalmit Protecta III Stainless Steel Emergency

Ex e Fluorescent / ATEX Category 2

 

 

 

(4) Chalmit Lomond Emergency Luminaire

Ex e Fluorescent / ATEX Category 2

 

 

 

(5) Chalmit Acclaim Recessible Luminaire

Ex e Fluorescent / ATEX Category 2

 

 

 

(6) Chalmit Curie Elite Recessible Luminaire

Ex e Fluorescent / ATEX Category 2

 

 

2. Zone 2

(1) Chalmit Sterling II Luminaire

Ex n Fluorescent / ATEX Category 3

 

 

 

(2) Chalmit Sterling II Emergency Luminaire

Ex n Fluorescent / ATEX Category 3

 

 

 

(3) Chalmit Sterling II Stainless Steel Luminaire

Ex n Fluorescent / ATEX Category 3

 

 

 

(4) Chalmit Sterling II Emergency Stainless Steel Luminaire

Ex n Fluorescent / ATEX Category 3

 

 

 

(5) Chalmit Protecta II Luminaire

Ex n Fluorescent / ATEX Category 3

 

3. Industrial

(1) Chalmit Protecta Luminaire

Surface Mounted Fluorscent

 

 

 

(2) Chalmit Protecta Emergency Luminaire

Surface Mounted Fluorescent

 

 

 

(3) Chalmit Protecta Stainless Steel Luminaire

Surface Mounted Fluorescent

 

 

 

(4) Chalmit Acclaim  Luminaire

Recessible Fluorescent

 

 

 

(5) Chalmit Sterling II Luminaire

Surface Mounted Fluorescent

 

 

 

(6) Chalmit Sterling II High Frequency Luminaire

Surface Mounted Fluorescent

 

 

 

(7) Chalmit Sterling II Stainless Steel Luminaire

Surface Mounted Fluorescent

 

 

 

(8) Chalmit Curie Luminaire

Recessible Fluorescent

 

 

(9) Chalmit Sterling II HF Stainless Steel

Surface Mounted Fluorescent

 

 

 

Technical Data

0.Chalmit Lighting Master CAT 20110611 02.pdf

 

Notice : Specification are subject to change without notice.

주의사항 : 소개된 제품 시스템의 사양, 재질, 치수, 기타 기재 내용은 제조공급사의 사정이나, 성능향상을 위해 예고 없이 단종, 대체되거나 변경되는 경우가 있으므로 양해를 부탁 드립니다. 기타 문의 상담은 하기 전문대리점을 통해 진행해 주시기 바랍니다.

국내 기술지원 및 구매상담

CUSTOMER SUCCESS IDK

CS CENTER 010.5353.9110

deric@jadongwha.com

www.tiatip.com

 

저작자 표시
신고
Posted by TIATIP

댓글을 달아주세요:: 네티켓은 기본, 스팸은 사절

Chalmit 샬밋 458 EPDM Floodlight 기술사양

 

안녕하세요 TIATIP입니다. 오늘 이 시간에는 샬밋 일반조명제품군 가운데 Chalmit 458 EPDM Floodling 에 대해 살펴보도록 하겠습니다.

 

 

Chalmit Lighting

458 EPDM Floodlight

Industrial Application

 

 

 

The Chalmit 458 is high wattage, weatherproof, robust EPDM floodlight is versitile in its mounting suitability as this is available in a base-mounted version (/B) and pole-mounted option (/P). The range has excellent vibration resistance making it ideal for use in hostile marine environments.

 

 

The Chalmit 458 is manufactured from EPDM rubber with a heavy duty borosilicate front glass and wire guard for maximum protection. The Chalmit 458 is suitable for GLS and hps lamps with maximum continuous operating temperature of +30°C.

Models with GLS lamps can operate at an ambient temperature as low as -40°C. A universal control gear box is required for models with hps lamps.
 
Available in 150W HPS, 250W HPS and 300W GLS lamp options.

 

 

 

CAT REF.

458I/150/HS

458I/250/HS

458I/300/GL

 

Technical Data

458 Industrial.pdf

 

Notice : Specification are subject to change without notice.

주의사항 : 소개된 제품 시스템의 사양, 재질, 치수, 기타 기재 내용은 제조공급사의 사정이나, 성능향상을 위해 예고 없이 단종, 대체되거나 변경되는 경우가 있으므로 양해를 부탁 드립니다. 기타 문의 상담은 하기 전문대리점을 통해 진행해 주시기 바랍니다

 

 

국내 기술지원 및 구매상담

CUSTOMER SUCCESS IDK

CS CENTER 010.5353.9110

deric@jadongwha.com

www.tiatip.com

 

저작자 표시
신고
Posted by TIATIP

댓글을 달아주세요:: 네티켓은 기본, 스팸은 사절

Chalmit 샬밋 비방폭 일반산업형 Bulkhead 라인업 소개

 

안녕하세요 TIATIP 입니다. 오늘 이 시간에는 샬밋 조명가운데 비방폭 일반산업형의  Chalmit Bulkhead 라인업에 대해 살펴보도록 하겠습니다.

 

1. Chalmit Lighting Nexxus Heavy Duty Bulkhead

Industrial Type

 

 

The industrial version of the Nexxus bulkhead luminaire is suitable for HID incandescent and compact fluorescent lamps. Its construction consists of a black-painted marine grade die cast aluminium LM6 alloy body with a heat resistant prismatic glass cover, silicone rubber sealing gasket and stainless steel fixings.

The Nexxus bulkhead offers a compact and versatile solution in many applications especially those with high levels of dirt and /or moisture.

They are simple to install, easy to maintain and durable.  The wide range of light sources and wiring options also makes the Nexxus a very versitile luminaire for many industrial applications.

ATEX Category 3 (Zone 2) hazardous area versions are available.

 

 

 

 

2. Chalmit Lighting Nexled LED Bulkhead

Industrial Type

The NexLED bulkhead luminaire utilises high output 1 Watt light emitting diodes (LED's) that provide a white, instant light that is highly visible.

 

Bulkheads offer a compact and versatile solution for many applications, especially in exposed conditions with high levels of dust and moisture.

 

 The enclosure is corrosion resistant marine grade aluminium with a toughened glass cover, silicone rubber sealing gasket and stainless steel fixings. The product can be fitted with either two or eight low power LED's making the NexLED an efficient luminaire for both mains and emergency mode operation from the backup battery. The use of LED technology means that light output in emergency mode is identical to mains operation, lamps switch off for one second when the mains fail then restart to indicate battery operation.

 
The bulkhead is simple to install, easy to maintain and durable. The LED's are more efficient than incandescent and most tungsten halogen lights and operate for up to 80000 hours eliminating relamping in many applications. This new lamp technology emits no heat forward, no ultra violet light, is mercury free and is not susceptible to vibration. Suitable for a wide range of ambient temperatures from -45°C to +55°C with light output unaffected by low temperatures. Where emergency lighting is required in ambient temperatures below -5°C the NexLED is available with a heated battery compartment which maintains the batteries at the required temperature to sustain emergency duration.

 

 

 

    

Technical Data (Datasheet)

Nexxus Heavy Duty Bulkhead Industrial.pdf

Nexled LED Bulkhead Industrial.pdf

 

 

Notice : Specification are subject to change without notice.

주의사항 : 소개된 제품 시스템의 사양, 재질, 치수, 기타 기재 내용은 제조공급사의 사정이나, 성능향상을 위해 예고 없이 단종, 대체되거나 변경되는 경우가 있으므로 양해를 부탁 드립니다. 기타 문의 상담은 하기 전문대리점을 통해 진행해 주시기 바랍니다.

국내 기술지원 및 구매상담

CUSTOMER SUCCESS IDK

CS CENTER 010.5353.9110

deric@jadongwha.com

www.tiatip.com

 

저작자 표시
신고
Posted by TIATIP

댓글을 달아주세요:: 네티켓은 기본, 스팸은 사절

Chalmit 샬밋 방폭위험지역 Zone2에 적용되는 Bulkhead 라인업 소개

 

안녕하세요 TIATIP 입니다. 오늘 이 시간에는 샬밋 방폭조명가운데 위험지역 Zone2에 적용가능한 Chalmit Bulkhead 라인업에 대해 살펴보고자 합니다.

 

  

 

 

1. Chalmit Lighting Nexxus Bulkhead

Ex n Luminaire

Zone 2 Application
ATEX CATEGORY 3

 

 

 


The Nexxus bulkhead luminaire is suitable for a wide range of discharge lamps, incandescent lamps and also compact fluorescent lamps.

The explosion protection is Ex nR utilising a restricted breathing enclosure. Bulkheads offer a compact and versatile solution in many applications especially those where conditions are exposed and have high levels of dirt and moisture. The enclosure is corrosion resistant aluminium with a heat resistant glass cover, silicone rubber sealing gasket and stainless steel fixings.

The bulkhead is simple to install, easy to maintain and durable. The wide range of light sources and wiring options makes the Nexxus a very versatile luminaire. Suitable for a wide range of ambient temperatures, -45°C to +55°C, dependant on lamp type and wattage.

New reflector system giving 20% increase in photometric performance.

 

 

 

 

 

2. Chalmit Lighting Nexxus II LED Bulkhead

Ex nR tb Luminaire

Zone 2
ATEX CATEGORY 3

 

 

The Nexxus II bulkhead luminaire is suitable for Zone 2 applications incorporating an array of light emitting diodes(LEDs) providing an instant white light that is highly visible.

The explosion protection is Ex nR tb utilising a restricted breathing enclosure. Bulkheads offer a compact and versatile solution in many applications especially those where conditions are exposed and have high levels of dirt and moisture. The enclosure is corrosion resistant aluminium with a heat resistant glass cover, silicone rubber sealing gasket and stainless steel fixings.

The bulkhead is a very low power consumption reulting in ultra long lifespan where relamping is not required. The Nexxus a very versatile luminaire that is easy to install with a high corrosion resistance, suitable for a wide range of ambient temperatures, -45°C to +55°C.

New reflector system giving 20% increase in photometric performance.

 

 

 

  

  

Technical Data (Datasheet)

Nexxus Bulkhead Hazardous.pdf

Nexxus II LED Bulkhead Hazardous.pdf

 

Notice : Specification are subject to change without notice.

주의사항 : 소개된 제품 시스템의 사양, 재질, 치수, 기타 기재 내용은 제조공급사의 사정이나, 성능향상을 위해 예고 없이 단종, 대체되거나 변경되는 경우가 있으므로 양해를 부탁 드립니다. 기타 문의 상담은 하기 전문대리점을 통해 진행해 주시기 바랍니다.

 

국내 기술지원 및 구매상담

CUSTOMER SUCCESS IDK

CS CENTER 010.5353.9110

deric@jadongwha.com

www.tiatip.com

 

저작자 표시
신고
Posted by TIATIP

댓글을 달아주세요:: 네티켓은 기본, 스팸은 사절

Chalmit 샬밋 방폭위험지역 Zone1에 적용되는 Bulkhead 라인업 소개

 

안녕하세요 TIATIP 입니다. 오늘 이 시간에는 샬밋 방폭조명가운데 위험지역 Zone1에 적용가능한 Bulkhead 라인업에 대해 살펴보고자 합니다.

 

 

 

 

1. Chalmit Lighting NexLED LED Bulkhead

Ex e Luminaire

Zone 1
ATEX CATEGORY 2

 


The NexLED bulkhead luminaire utilises high output 1 Watt light emitting diodes (LED's) that provide a white, instant light that is highly visible.

Suitable for Zone 1, the protection being flameproof increased safety. Bulkheads offer a compact and versatile solution in many applications especially those where conditions are exposed and have high levels of dust and moisture. The enclosure is corrosion resistant marine grade aluminium with a toughened glass cover, silicone rubber sealing gasket and stainless steel fixings.

The product can be fitted with either 2 or 8 LED's and offers a very low power consumption product well suited to UPS systems. The bulkhead is simple to install, easy to maintain and durable.

The LED's are more efficient than incandescent and most tungsten halogen lights and operate for over 60000 hours eliminating relamping in many applications. This new lamp technology emits no heat or ultra violet light and is mercury free.

Suitable for a wide range of ambient temperatures from -45ºC to +55ºC with light output not affected by low temperatures.

 

 

2. Chalmit Lighting NexLED Emergency LED Bulkhead
Ex e ib im Luminaire

Zone 1
ATEX CATEGORY 2

 

The NexLED bulkhead luminaire utilises high output 1 Watt light emitting diodes (LED's) that provide a white, instant light that is highly visible.

 

 

Bulkheads offer a compact and versatile solution for many applications, escpecially in exposed conditions with high levels of dust and moisture. The enclosure is corrosion resistant marine grade aluminium with a toughened glass cover, silicone rubber sealing gasket and stainless steel fixings. The product can be fitted with either two or eight low power LED's making the NexLED an efficient luminaire for both mains and emergency modeo operating from the backup battery. The use of LED technology means that light output in emergency mode is identical to mains operation, lamps switch off for one second when the mains fail then restart to indicate battery operation.

 

The bulkhead is simple to install, easy to maintain and durable. The LED's are more efficient than incandescent and most tungsten halogen lights and operate for up to 80000 hours eliminating relamping in many applicaitons. This new lamp technology emits no heat forward, no ultra violet light, is mercury free and is not susceptible to vibration. Suitable for a wide range of ambient temperatures from -45℃ to +55℃ with light output unaffected by low temperatures. Where emergency lighting is required in ambient temperatures below -5℃ the NexLED is avaible with a heated battery compartment which maintains the batteries at the required temperature to sustain emergency duration.

 

 

3. Chalmit Lighting Nevis Bulkhead
Ex d e Luminaire

Zone 1
ATEX CATEGORY 2

 

 

The Nevis bulkhead is designed for applications where a low profile robust luminaire is required. It is suitable for mounting on handrails and walls as well as ceilings and in restricted dirty places.

The ATEX rated bulkhead suitable for Zone 1 and Zone 21 applications is made from corrosion resistant aluminium alloy and toughened boro-silicate glass using stainless steel fastenings. It has an IP66/67 rating making it ideally suited to use in hazardous area environments

The luminaire is suitable for high pressure discharge lamps up to 70W HPS and 125W mercury vapour and also compact fluorescent lamps up to 26W, 200W GLS and 55W QL induction lamps. These give an efficient all around light distribution.

The large side mounted increased safety terminal chamber eliminates the need for flameproof glands and allows for flush mounting with easy cable access.

 

 

4. Chalmit Lighting Nevis LED Bulkhead

Ex d e Luminaire

Zone 1
ATEX CATEGORY 2

 

 

 


The Nevis LED bulkhead is an ATEX rated bulkhead suitable for Zone 1 and Zone 21 applications.  The ultra bright LEDs will deliver an instant white light which has a longer life with light output & efficiency equivalent to a 70W HPS, making this a very cost effective luminaire.

The Nevis LED has these key benefits:
 
·          Long Operational Lifespan = 60,000 hours
·          Reduced Power Consumption = Cost effective
·          Operational at Low Temperatures -55°C

 

The Nevis has a side mounted increased safety terminal chamber, this eliminates the need for flameproof glands and allows for flush mounting with easy cable access. Designed for low profile applications, the bulkhead can be mounted on walls, handrails and ceilings - ideal for walkways or restricted height areas making the Nevis suitable for extreme environmental conditions.

 

 

 

 

 

Technical Data (Datasheet)

Nexled Bulkhead Hazardous.pdf

Nexled Emergency Hazardous.pdf

Nevis Hazardous.pdf

Nevis LED Hazardous.pdf

 

 

Notice : Specification are subject to change without notice.

주의사항 : 소개된 제품 시스템의 사양, 재질, 치수, 기타 기재 내용은 제조공급사의 사정이나, 성능향상을 위해 예고 없이 단종, 대체되거나 변경되는 경우가 있으므로 양해를 부탁 드립니다. 기타 문의 상담은 하기 전문대리점을 통해 진행해 주시기 바랍니다.

 

국내 기술지원 및 구매상담

CUSTOMER SUCCESS IDK

CS CENTER 010.5353.9110

deric@jadongwha.com

www.tiatip.com

 

저작자 표시
신고
Posted by TIATIP

댓글을 달아주세요:: 네티켓은 기본, 스팸은 사절

T&B, Liquidtight Flexible Cord & Cable Fittings, 2255 사양소개

 

안녕하세요 TIATIP 입니다.

 

오늘 이 시간에는 Flexible Cord & Cable Fittings 가운데, 2255 사양에 대해 살펴보도록 하겠습니다. 

 

Liquidtight Flexible Cord & Cable Fittings

 

 

 

 

Description :

1 in. 90 degree malleable iron liquidtight strain relief cord connector, cord range-.500-.625.

 

 

 

 

Technical Data

Flexible Cord Cable Fittings CAT.pdf

Flexible Cord Cable Fittings Spec.pdf

Portable Cord Selection Table.pdf

 

 

 

 

 

Application :

Suitable for use in hazardous locations where general purpose equipment is specifically permitted by NEC 501-4(b).

Meets Coast Guard CG293

 

 

 

 

 

 

내 기술지원 및 구매상담처

CUSTOMER SUCCESS IDK

deric@jadongwha.com

www.tiatip.com

 

저작자 표시
신고
Posted by TIATIP

댓글을 달아주세요:: 네티켓은 기본, 스팸은 사절

Ty-Met, Stainless steel, Releasable type cable tie, YRL-5-150-BC 제품소개

 

안녕하세요 TIATIP 입니다.

 

오늘 이 시간에는 Stainless steel, Releasable type cable tie, 150 x 5 mm, black Polyester 316 grade stainless steel, YRL-5-150-BC 에 대해 살펴보도록 하겠습니다.

 

Thomas&Betts

Ty-Met

Stainless Steel Ties

The Ulimate Solution

 

 

 

 

 

Description

Stainless steel ties with a unique buckle design, that allows the tie to be unfastened for re-use. Recommended for applications in extreme conditions and hazardous areas, indoor and outdoor, such as the petrochemical and food processing industries, power stations, mining, shipbuilding, offshore and other aggressive environments.

 

 

 

Technical Information

CAT No.: YRL-5-150-BC

Type : Releasable Type

Material : 316 Grade Stainless Steel

Coating : Polyester

Temperature Range : -80℃ to +150℃

Colour : Black

Halogen Free : Yes

UV-Resistant : Yes

TyMet Spec 01.pdf

 

 

 

The new Releasable Type stainless steel ties from Thomas & Betts
have a unique buckle design that allows the ties to be unfastened
for re-use.

 

 

• Releasable and re-usable
• Fast, easy and reliable installation - can be installed by hand
• The additional ears can be bent back over the fastened tie

   to increase the tensile strength

 

 

Approvals

Det Norske Veritas Approval : E-7508

Germanischer Lloyd Approval : 40 629-01 HH

 

 

 

 

Ordering Information

Length(mm) : 150

Width(mm) : 5

Thickness(mm) : 0.61

Max. Bundle Diameter(mm) : 35

Min. Tensile Strength(N) : 334

Quantity(Pieces) : 100

Packaging Type : Bag

Tooling : CT1-TB, CT2-TB, CT4-TB

Note : 1334 N tensile strength rating for DNV

 

 

 

 

CAT No. Releasable Type (Coated)

YRL-5-150-BC,YRL-5-230-BC,YRL-5-330-BC,YRL-5-450-BC

YRL-5-650-BC,YRL-10-150-BC,YRL-10-230-BC,YRL-10-330-BC

YRL-10-450-BC,YRL-10-650-BC,YRL-10-750-BC, 

YRL5150BC,YRL5230BC,YRL5330BC,YRL5450BC,YRL5650BC

YRL10150BC,YRL10230BC,YRL10330BC,YRL10450BC,YRL10650BC

YRL10750BC,Ty-Met,TyMet

 

 

 

 

 

 

 

 

내 기술지원 및 구매상담처

CUSTOMER SUCCESS IDK

deric@jadongwha.com

www.tiatip.com

 

 

 

저작자 표시
신고
Posted by TIATIP

댓글을 달아주세요:: 네티켓은 기본, 스팸은 사절

Thomas&Betts(TnB,T&B), Manual Crimp Tool, ERG4001 사양소개

 

안녕하세요 TIATIP 입니다.

 

오늘 이 시간에는 각종 터미널 압착에 사용되는 클램프 공구 ERG4001에 대해 살펴보도록 하겠습니다.

 

 

 

Thomas&Betts, T&B, TnB

Wire Termination Tools

Comfort Crimp® Compression Tools

ERG4001

Redesigned family of termination tools sets a new standard for manual crimping tools!

 

 

For Installing STA-KON Nylon and Vinyl Insulated Terminals, Disconnects, And Splices on Copper Wire, 22-10 AWG

 

CAUTION : Handles Non-Insulating, Do Not Crimp Energized Wires

 

 

Sta-Kon® Comfort Crimp® Compression Tools previously set the standard
for manual crimp tools. Now, Thomas & Betts engineers have made
a great line of tools even better with the newly redesigned Sta-Kon®
Comfort Crimp® Compression Tools. We kept all the performance
features that made the tools industry leaders such as the Shure-Stake®
mechanism and interchangeable dies with color-coded die nests, and
focused on creating the best possible user experience in terms of comfort
and reduction of strain.

 

 

 

Ergonomic handles position the user’s hands correctly to minimize the
risk of strain, and soft, over-molded grips cushion fingers and palm for
user comfort. A new Crimp-Assist™ foot stabilizes the tool when the
user needs to place it on a work surface for leverage to crimp larger
connectors. Best of all, the redesigned Comfort Crimp® tools require
25% less handle force to complete the crimp cycle than the previous
generation — and up to 75% less handle force than competing tools!

 

 

 

Requiring the lowest handle force of any tool in its class, the new Comfort
Crimp® family provides maximum comfort to installers, without sacrificing
the durability or performance associated with Thomas & Betts tools.

 

 

CAT No.

ERG4001, ERG4002, ERG4005, ERG4006, ERG4007, ERG4008

 

 

Technical Data

CAT03.08 StaKon Wire Termination Insulation.pdf

ERG4001 Drawing.pdf

ERG4001 Instruction Sheet.pdf

Stakon Die Selection Chart.pdf

Stakon Tool Selection Chart.pdf

 

 

 

 

내 기술지원 및 구매상담처

CUSTOMER SUCCESS IDK

deric@jadongwha.com

www.tiatip.com

 

저작자 표시
신고
Posted by TIATIP

댓글을 달아주세요:: 네티켓은 기본, 스팸은 사절

KOPEX-EX Conduit System, Fitting Instructions for Non-Metallic Braided EXBQ and EXBB Conduit 설치가이드

 

안녕하세요 TIATIP 입니다.

 

오늘 이 시간에는 Ex'e'타입의 Conduit System과 관련하여, EXBQ시리즈의 Fitting과 EXBB Series의 Conduit의 설치가이드를 전해드립니다.

 

 

 

 

 

Thomas&Betts

KOPEX-Ex Conduit Systems

EXBB

EXBQ, EXBQM, EXBQA

 

 

Over Braided Conduit

EXBB Conduit Series

 

 

 

 

Straight Male Conduit Fitting

EXBQ Conduit Gland/Fitting Series

EXBQM & EXBQA Series

 

 

 

 

 

 

Wrap sellotape around conduit and cut to length required. Apply the “nut out” over the braiding before removing tape.

 

 

 

 

Remove tape and pull back braided sheath. Apply “nut in” so that approximately five convolutions protrude.

 

 

 

Apply seal with chamfered edge towards the “nut in” three corregations in from the end of the conduit.

 

 

 

Loosely assemble body into the “nut in.”
If using with a plain hole, fully tighten nut into body to secure gland on conduit.
If using with a threaded entry, leave nut loose to allow gland to freely rotate
about the conduit. Screw body into entry, then fully tighten nut.

 

 

 

Position braiding over steps of “nut in” and secure with “nut out” ensuring braid is trapped between the nuts.

 

 

Special Conditions for Safe Use:
When the gland is used for increased safety or dust protection, the entry of the enclosure and the female thread of the gland is to be sealed (in accordance with IEC60079-14) in order to maintain the ingress protection rating of the associated enclosure.

 

 

 

CAT Number

EXBB,EXBQ,EXBQM,EXBQA,EXBB0310, EXBB0330, EXBB0350,EXBB0410, EXBB0430, EXBB0450,EXBB0510, EXB0530, EXBB0550,EXBB0610, EXBB0630, EXBB0650,EXBB0710, EXBB0730, EXB0750,EXB0810, EXBB0830, EXBB0850,EXBQM0304, EXBQM0404, EXBQM0505, EXBQM0606, EXBQM0707, EXBQM0808,EXBQA0304, EXBQA0404, EXBQA0505, EXBQA0606, EXBQA0707, EXBQA0808,EXBQA0305

 

 

 

 

 

Installation Guide 

 

http://youtu.be/sLYP8cZvxZY

 

 

 

Technical Data

 

CAT02.06 KopexEx Hazardous Location Conduit Systems.pdf

CAT21.Adaptaflex and KopexEx.pdf

CAT26.02 KopexEx Stainless Steel Conduit Systems.pdf

DTS KOPEX Hazardous Area CAT02.pdf

DTS KOPEX Installation Guide.pdf

EXB EXBB Conduit Spec 20110522.pdf

EXBQ Fittings Spec 20120409.pdf

 

 

 

 

 

 

 

 

 

 

내 기술지원 및 구매상담처

CUSTOMER SUCCESS IDK

deric@jadongwha.com

www.tiatip.com

 

 

 

저작자 표시
신고
Posted by TIATIP

댓글을 달아주세요:: 네티켓은 기본, 스팸은 사절

KOPEX-EX Conduit System, Fitting Instructions for Non-Metallic EXPQEXB Conduit 설치가이드

 

안녕하세요 TIATIP 입니다.

 

오늘 이 시간에는 Ex'e'타입의 Conduit System과 관련하여, EXPQ시리즈의 Fitting과 EXB Series의 Conduit의 설치가이드를 전해드립니다.

 

 

 

Thomas&Betts

KOPEX-Ex Conduit Systems

EXB

EXPQ, EXPQM, EXPQA

 

Anti-Static Conduit, EXB Conduit Series

 

 

 

 

 

Straight Male Conduit Fitting

EXPQ Conduit Gland/Fitting Series

EXPQM & EXPQA Series

 

 

 

 

 

 

Apply nut and seal over conduit, ensuring chamfered edge of seal is facing towards nut. Seal to be positioned three corrugations in from the end of the conduit.

 

 

 

If using with plain hole, fully tighten nut onto body to secure gland onto conduit.

 


If using with threaded entry, leave nut loose to allow gland to freely rotate about the conduit. Screw body into entry, then fully tighten nut to complete installation.

 

 

 

 

 

Installation Guide

 

http://youtu.be/duJ6vW-TV4g

 

 

CAT Number

EXB,EXPQ,EXPQM,EXPQA, EXB0310, EXB0330, EXB0350,EXB0410, EXB0430, EXB0450,EXB0510, EXB0530, EXB0550,EXB0610, EXB0630, EXB0650,EXB0710, EXB0730, EXB0750,EXB0810, EXB0830, EXB0850,EXPQM0304, EXPQM0404, EXPQM0505, EXPQM0606, EXPQM0707, EXPQM0808,EXPQA0304, EXPQA0404, EXPQA0505, EXPQA0606, EXPQA0707, EXPQA0808,EXPQA0305

 

 

 

 

 

Technical Data

CAT02.06 KopexEx Hazardous Location Conduit Systems.pdf

CAT21.Adaptaflex and KopexEx.pdf

CAT26.02 KopexEx Stainless Steel Conduit Systems.pdf

DTS KOPEX Hazardous Area CAT02.pdf

EXB EXBB Conduit Spec 20110522.pdf

EXPQ Conduit Spec 20110121.pdf

 

 

 

 

 

 

 

 

내 기술지원 및 구매상담처

CUSTOMER SUCCESS IDK

deric@jadongwha.com

www.tiatip.com

 

 

 

저작자 표시
신고
Posted by TIATIP

댓글을 달아주세요:: 네티켓은 기본, 스팸은 사절

Hawke ATEX INLINE Connector, ControlEx Termination Hook up Procedure 자료

 

안녕하세요 TIATIP 입니다.

 

오늘 이 시간에는 Hawke ATEX INLINE Connector, ControlEx 시리즈의 Termination Hook up Procedure 관련 자료를 소개합니다. 

 

 

 

HAWKE

ControlEx Termination Procedure

 

IMPORTANT NOTE


1. Hawke International does not recommend the use of their ControlEx Connectors in applications where rigid PVC/SWA/PVC power cabling (typically to BS 6346 standards) is used in portable / semi-portable applications.


2. Barrier type glands must be fitted to flexible power and loose filled control cabling entering the connectors to maintain the Exd protection concept and to reduce the potential for core movements within the cable being transferred to the connector’s internal components. Where connectors are terminated to topside umbilical cables, or portable connectors, a barrier type cable gland should always be used.


3. Hawke Ex Connector products are designed to be used in multi-voltage applications in circuits up to 660V AC/DC. It is
possible that on certain installations, there may be a mix of applications utilising different voltages on the Connector
products. In these instances, the installer / circuit designer must ensure that the plugs and sockets, or their associated
cabling, is clearly marked with the correct circuit voltage and current rating to ensure that the equipment being supplied is
matched correctly with the supply voltage. The variable insert positions which are a feature of the Connectors may also be
used to provide additional means of safety in these applications.

 

ControlEx Hook Up Procedure

 

1. Remove the CP/CR connector assembly, electrical insert and cable gland
(sold separately) from their packaging.


2. Terminate the cable into the cable gland in accordance with the manufacturer’s Instructions. Ensure a minimum tail length of 130mm.

 


 

3. Unscrew the rear engaging nut from the connector shell, removing the rear shell and keyway tube.

 

  

4. Slide the rear engaging nut over the rear shell as shown and screw the rear shell onto the entry thread of the cable gland ensuring there is a sealing washer between the gland and rear shell. A small amount of Loctite 638
or equivalent can be added to the cable gland thread at this stage to further help prevent loosening of the cable gland in portable applications.

 


Where a thread adaptor is being used, ensure a suitable IP seal is fitted between the cable gland and thread adaptor, and thread adaptor & running coupler. If the thread adaptor has an integral O-Ring, please ensure this makes full contact with the cable gland and running coupler to maintain the IP
protection. Check to ensure the captive O-Ring seal on the rear shell is in place and is undamaged

 

If the tab washer is being used, ensure this is fitted in the orientation shown. Use the flats on the rear shell to further tighten.

 

 

 

 

5. Cut the conductors to the length shown in the table below.

 

 

Note: Maximum tolerance is to allow for twisted cables and placement of cores within connector shell. If core spacing relative to insert numbering does not require excess core, use minimum cut lengths.

 

6. Strip back the insulation from the conductor’s as shown

 

 

 

 

7. Proceed to step 8 if internal earthing is not required.

 


NOTE: If internal earthing is not being used, the internal earth crimp must not be fitted and the grub screw in the rear shell must be removed

 


If earthing is required slide the internal crimp (supplied with CP/CR inserts) over the earth conductor and crimp using suitable tool. The stud can then be fitted into the rear shell and fastened using the grub screw shown. The stud on the earth crimp should not protrude from the outer diameter of the rear shell. Adjust if necessary.

 

 

8. a) Solder inserts – black (1.5 – 35mm²). Tin the conductors and fill the solder cups on the back of the inserts with solder as required Solder conductors in place and remove any solder spikes/excess from the solder cup. It is advised that heat shrink should be fitted over the connection at this point

b) Solder inserts – white (1.5 – 4mm2). As above, however, inserts should be soldered outside of the insert body and not fully assembled. If the contacts are to be solder terminated to the conductors, this must be done prior to insertion
through the rear contact retainer. It is advised that heat shrink should be fitted over the connection at this point Then follow (c ii & iii).


c) Crimp Inserts (1.5 – 4mm²) – white.

 

i) Crimp the conductors into the contacts using Weidmuller CTX CM 1.6/2.5 crimp tool HCT1, or Astro Crimp Tool HCT2. For 0.75 to 1.5mm² conductors use the 1.5 die. For 1.6 to 4mm² use the 2.5 die. It is advised that heat shrink should be fitted over the connection at this point


ii) Feed the contacts through the required numbered hole on the rear contact retainer and slide the insertion tool over the contacts up to the groove (one end for pin and one for socket). Clip the groove on the contact into position in the rear contact retainer with the tool.

 

 

 

iii) Align the main pip on the rear contact retainer with the key on the front contact retainer and slide over the contacts into position. Ensure the 2 smaller pips are also in line

 

 

d) Crimp Inserts (6 – 35mm²) – black. Undo the grub screws on the crimp barrels and slide them off the back of the contacts. Slide the conductors into the back of the barrel. Orientate the barrel so that the grub screws are pointing
outwards and crimp with a suitable crimp tool.


Push the barrels back onto the rear of the contacts and tighten grub screw into the groove on the contact. Back off grub screw half a turn on crimp barrels of 10mm² or larger to allow them to slide up and down the contact slightly

 

 

 

 

 

9. Clip spacer tube over conductors. Bend conductors slightly so that there is no or minimal gap between the insert/spacer tube and rear shell. On crimp insert of 10mm² or larger, slide the crimp barrels up and down the contacts to achieve this and then lock them in place by tightening the grub screw’s on the crimp barrels.

The insert has 3 pips, shown below, which should be located as shown. The main centre keyway should align with the centre of the spacer tube

 

 

 


NOTE: If being used on offshore topside applications where extreme temperature fluctuations or extreme levels of humidity may be present, it is advisable to use Dow Corning 4 Electrical Insulating Compound within the spacer tube to help prevent any possible humidity build-up. See point 15 below

 

 

10. Looking from the front of the connector shell, align the key on the insert to the required key inside the connector and slide the whole assembly into the shell. The EX16 connector has 3 keyways, and all other connectors have 5 possible keyways

 

 

 

 

11. Fully screw the rear engaging nut onto the thread on the connector shell, do not rotate the connector shell during this process. Tighten grub screw in rear engaging nut. There should be a gap visible of no more than 1mm between running coupler and shell

 

 

 

 

12. If the tab washer is being used, fix the tab using the button head screw to the rear engaging nut. Bend the tabs over the
flats of the cable gland.


13. If being used, terminate the external earth to the ring terminal crimp provided with the insert. Remove the button head
screw and spring washer from the rear engaging nut. Attach the crimp to the rear engaging nut as shown above


14. The connector is now ready for use. Please refer to the ‘Hook Up’ procedure.

15. If additional protection is required due to extreme atmospheric conditions, before inserting the assembled connector insert and spacer tube into the connector shell (step 10 above) Dow Corning 4 Electrical Insulating Compound can be used to fill the spacer tube. It is recommended that the running coupler be filled, along with the inner face of the insert to ensure no humidity can affect the contacts

 

 

ControlEx MK IV Connector Hook Up Procedure

 

Before commencing hook up, a visual inspection should be carried out on the cable / gland / connector assembly. The assembly should be checked to ensure that all of the assembly components are tight. If the assembly components have loosened during transportation / cable installation, they should be retightened in accordance with the relevant assembly instruction sheets without twisting the cable in the cable gland / connector assembly.

 

Areas to be checked:

 

 

 

 

NB: These areas should also be checked as part of a routine maintenance programme.

 

1) Turn off the power to the connectors.
2) Ensure the connectors are both set to the same keying position number and are of the same insert type.

 

 

 

 

3) Engage the CP connector with the BR / CR connector and align the key on the CP connector to the keyway on the BR / CR connector.

 

 

engaging nut clockwise onto the BR/CR shell. If the engaging nut will not screw on more than half a
turn, then the connectors are set to different keying positions.

 

 

5) Tighten the grub screw on the engaging nut.

 

6) If the optional locking pin is being used, this should be fitted at this stage, once the connectors are fully mated.

 

 

7) To disconnect, turn off the power, slacken the tightened grub screw, turn the engaging nut anticlockwise and remove the connector. If power is to be put through the connectors whilst de-mated, then a flameproof cap (available separately) must be fitted.

 

 

 

 

Technical Data

ControlEx MKIV Spec.pdf

ControlEx Spec.pdf

ControlEx MKIV Hookup Procedure 20131105.pdf

ControlEx MKIV Hookup Procedure 20131218.pdf

ControlEx Hook up procedure 20091202.pdf

ControlEx Inline connector termination 20091202.pdf

0.Ex Connectors Master Catalogue 20130819.pdf

 

 

 

 

 

 

내 기술지원 및 구매상담처

CUSTOMER SUCCESS IDK

deric@jadongwha.com

www.tiatip.com

 

저작자 표시
신고
Posted by TIATIP

댓글을 달아주세요:: 네티켓은 기본, 스팸은 사절

Hawke Exd Connector, MK IV ControlEx 기술사양

 

안녕하세요 TIATIP 입니다.

 

오늘 이 시간에는 호크 방폭커넥터 제품군 가운데, Contrl 관련 애플리케이션에 적합한 Hawke MK IV ControlEx 시리즈를 살펴보도록 하겠습니다.

 

 

 

HAWKE

Range For Harsh and Hazardous Locations

Hazardous Area Connector

MK IV ControlEx

IECEx/ATEX Certificate 

 

Note: Inline connector receptacle (CR) also available

 

 

Overview

 

The 4th generation ControlEx has been designed as a result of over 20 years of plug-and-socket experience. Manufactured in Stainless steel, the connectors provide unrivalled durability in hostile environments.

 

Both ATEX/IECEX, GOST & NEC certified, the connectors are Exd rated with an Ingress Protection rating of IP66 / IP67 and have industry leading DTS01 deluge protection.

 

 

 

 

The wide range of insert variables can handle up to 60 cores.

 

Other improvements include an all-new padlock facility, allowing the connectors to be securely locked to prevent accidental un-plugging of equipment and improved secure cap fixings.

 

The 4th generation ControlEx maintains many of the original features which made its predecessor extremely popular, including a variable keying system to prevent accidental cross-mating, modular gold-plated field crimpable inserts for ease of wiring and a fully inspectable flameproof barrier providing direct inspection of the flameproof seal.

 

 

 

 

 

Tamb: -40°C to +60°C.

II2 GD Exd IIC Gb, Extb IIIC T95Db.

IP66, 67

DTS01 deluge protected.

Certificate No's Baseefa12ATEX0014X & IECEx BAS 12.0006X.

 

ControlEx Features

 

(1) Easy Fieldwireable
Pin and socket inserts are numbered front and back to assist wiring and avoid
termination errors. Crimp and solder inserts available.

 

 

(2) Internal Keyway Spacer

Eases accessibility for termination as tube fitted after termination complete,
along with allowing easy installation into the required keyed position (See (4))

 

 

(3) Locking Pin
Optional locking pin provides the facility for mated connectors to be permanently
locked, via the use of a padlock, ensuring they cannot be separated under load. (Padlock not supplied)

 

 

 

 

(4) Keying Position
The unique visual 5 position insert keying system (3 on Ex16) along with the integral machined keyways prevent contact damage and ensures safe use by eliminating the possibility of misconnection of adjacent circuits.

 

 

 

(5) Running Coupler
Allows the connector to be installed onto a pre-assembled cable gland. Connector is rear loading and includes locking engaging nut.

  

 

 

(6) Acme Thread at Mating Interface
Unique ACME thread offers a smooth and quick fully mating action.

 

 

 

(7) Fully Inspectable Flameproof Barrier
Provides direct inspection of the flameproof seal and offers users the peace of mind that the connector is safe for installation.

 

 

 

(8) Anti-Rotation Device
Connector plugs and receptacles come complete with anti-rotation ring, which
when fitted between the connector and gland, helps to eliminate the possibility of the gland loosening, locking this in position.

 

 

 

 

 

Technical Data

 

ControlEx MKIV Spec.pdf

ControlEx MKIV Hookup Procedure 01.pdf

ControlEx MKIV Hookup Procedure 02.pdf

0.Ex Connectors Master Catalogue 20130819.pdf

 

 

 

 

 

내 기술지원 및 구매상담처

CUSTOMER SUCCESS IDK

deric@jadongwha.com

www.tiatip.com

 

 

저작자 표시
신고
Posted by TIATIP

댓글을 달아주세요:: 네티켓은 기본, 스팸은 사절

Hawke Exd Connector, InstrumEx 기술사양

 

안녕하세요 TIATIP 입니다.

 

오늘 이 시간에는 호크 방폭커넥터 제품군 가운데, Instrument 연결 애플리케이션에 적합한 Hawke InstrumEx 시리즈를 살펴보도록 하겠습니다.

 

 

HAWKE

Range For Harsh and Hazardous Locations

Hazardous Area Connector

InstrumEx

IECEx/ATEX Certificate 

 

Overview

This revolutionary design allows the live mate and de-mating of signal and low power in hazardous areas safely and quickly. The InstrumEx connector is available with two insert options:

 

 

 

The 4-way option will accept cores ranging between 0.5mm² and 2.5mm² and can operate up to a maximum current of 10A (AC1) at 250V AC & 2.5A (DC1) 60V DC.

 

The 8-way option, designed predominantly for Ethernet applications, will accept cores ranging between 0.14mm² and 0.37mm² and can carry 1A (AC1) at 60V AC & 0.5A (DC1)60V DC. InstrumEx connectors include an integral Hawke cable gland for easy termination of both armoured and un-armoured cables.

 

 

 

 

Tamb: -40°C to +60°C.

II2 GD Exd IIC ExtD T85.

IP66, 67

DTS01 deluge protected.

 

 

 

Technical Data

InstrumEx Spec.pdf

InstrumEx BRO 200808XX.pdf

InstrumEx Manual 20140403.pdf

0.Ex Connectors Master Catalogue 20130819.pdf

 

  

 

 

내 기술지원 및 구매상담처

CUSTOMER SUCCESS IDK

deric@jadongwha.com

www.tiatip.com

 

저작자 표시
신고
Posted by TIATIP

댓글을 달아주세요:: 네티켓은 기본, 스팸은 사절

Hawke Live Demateable Connector, InstrumEx Termination Hook up Procedure 자료

 

안녕하세요 TIATIP 입니다.

 

오늘 이 시간에는 Hawke Live Demateable Connector, InstrumEx 시리즈의 Termination Hook up Procedure 관련 자료를 소개합니다.

 

 

 

 

HAWKE

InstrumEx Termination Procedure

 

IMPORTANT NOTE

1. Hawke International does not recommend the use of their InstrumEx Connectors in applications where rigid PVC/SWA/PVC power cabling (typically to BS 6346 standards) is used in portable/semi-portable applications.


 

2. Hawke International recommends that barrier type glands are fitted to flexible power and loose filled control cabling entering the connectors to maintain the Exd protection concept and to reduce the potential for core movements within the cable being transferred to the connector’s internal components.


 

3. Hawke Ex Connector products are designed to be used in multi-voltage applications in circuits: 4 way up to 250V AC, 4 way up to 60V DC and 8 way up to 60V AC/DC. It is possible that on certain installations, there may be a mix of applications utilising different voltages on the Connector products. In these instances, the installer / circuit designer must ensure that the plugs and sockets, or their associated cabling, is clearly marked with the correct circuit voltage and current rating to ensure that the equipment being supplied is matched correctly with the supply voltage. The variable insert positions which are a feature of the Connectors may also be used to provide additional means of safety in these applications.

 

 

 

 

CP / CR PROCEDURE


1) Unscrew the middle nut and back nut from the connector body and remove the armour clamping ring, spigot and insert. If you have purchased a connector with the optional backnut clamp and / or flange, slide these down the cable now (clamp first).

 

 

2) Remove the two seal assembly’s from the box and choose the required seal to suit the diameter of the cable outer jacket.

 

 

 

3) Insert the seal into the back nut, ensuring that the flange on the seal goes past the thread as shown.

 

 

 

 

 

4) Screw the back nut onto the middle nut. Do not compress the seal at this stage.

 

 

 

5) Slide the middle nut, backnut and armour clamping ring over the cable ensuring that the clamping ring is pointing in the required direction for the size of armour / braid. The alternative ring is supplied in the box.

 

                          

 

 

 

6) Strip back the outer jacket and armour (if present) as shown below.

 

 

 

7) Strip back the inner sheath level with the armour to expose the insulated conductors as shown below. If unarmoured, strip back to the outer jacket.

 

 

 

 

 

ARMOURED / BRAIDED CABLE


8) Push the inner sheath of the cable through the spigot.
Spread the armour / braid over the spigot until the end of the armour / braid is up against the shoulder of the spigot. Position the armour clamping ring onto the armour/braid.

 

 

 

9) Place the connector body over the spigot engaging the octagonal portion of the spigot. Move the middle nut up to meet the connector body. Place a 27 A/F spanner on the flats of the connector body and hold it in position.
Hand tighten the middle nut to the connector body, then turn a further ½ to ¾ turn with a 27 A/F spanner.

 

 

 

10) Unscrew the middle nut and visually inspect the armour has been  successfully clamped between the armour spigot and the clamping ring.

 

 

 

 

UNARMOURED CABLE
(If earth is to be terminated to connector shell. Otherwise proceed to step 15)


11) Strip back the earth conductor as shown below. If the earth is being carried through a contact as well as being connected to the shell, see fig b.

 

 

 

12) Crimp the flat blade earth crimp onto the earth conductor as shown below. Ensure the blade of the crimp is outermost as shown and that the crimp is pushed all the way up to the insulation of the earth conductor.

 

 

13) Push the conductors through the spigot and place the blade of the crimp on the taper of the spigot.

 

 

 

 

 

 


the blade of the crimp and lock into position by following steps 9 and 10 of the armoured / braided cable procedure.

 

15) Strip back the conductors as shown below.

 

 

 

 

 16) Remove the contacts from the contact retainers. Crimp the contacts onto the conductors using the Hawke crimp tool only (part number 901849). Ensure that the insulation of the conductor is up against the shoulder of the contact. When terminating 0.5mm² or 1.5mm² wire, ensure the conductor is pushed all the way into the smaller hole of the contact and that the contact is square in the crimp tool.


CAUTION: EXCESSIVE FORCE MAY BEND THE CONTACTS


Alternatively, conductors may be soldered into the contacts. Ensure that the cable installation is the same on the mating half. Hawke recommends that wiring details are placed on the cable outer jacket near to the connector.

 

 

17) Splay out the contacts and fit them through the slots in the rear contact retainer, ensuring they line up with the relevant numbered hole on the front contact retainer (ensure keys are aligned - see step 18). Unused contacts
should be omitted if not required to ease assembly.

 

 

 

18) Slide the front contact retainer over the contacts and snap into place with the rear contact retainer. Push the clips of the rear contact retainer firmly down to ensure they are not protruding (will only fit in the correct orientation).

 

 

19) Slide the insert into the connector body, aligning the half round key on the rear contact retainer with the required half round keyway in the connector body. (The colour coded or numbered keying position is shown on the front of the connector body. No colour coding or numbering for default 12 o’clock position – see picture inset). It should be noted that colour coded and numbered connector bodies are mutually interchangeable. Push the octagonal portion of the spigot into the connector body.

 

 

20) Slide the middle nut over the clamp / spigot and hand tighten onto the connector body, then further tighten ½ to ¾ of a turn with a 27 A/F spanner while holding the front shell with a 27 A/F spanner

 

 

 

 

 

21) Hand tighten the backnut onto the middle nut. Further tighten 1 to 1 ½ turns with a 27 A/F spanner while holding the middle nut with a spanner.

 

 

 

22) If the optional mounting flange is required, slide the flange over the backnut and position on the middle nut. Align the grub screw with one of the flats and tighten. If the flange is being used on a CR connector, it may also be
placed on the connector body as shown over.

 

 

23) If the optional cable clamp has been purchased, tighten the screws on the clamping bars equally until the clamping bars touch the cable. Tighten each screw a further 2-4 turns or until adequately clamped.


DO NOT OVERTIGHTEN AS THIS COULD DAMAGE THE CABLE.


If the cable clamp is being used with unarmoured cable, the connector should be earthed via the crimp with a 4mm² conductor.

 

 

 


24) Screw the cap back onto the connector. Stick the corresponding round colour coded / numbered sticker onto label in the circular space provided.
(white = 12 o’clock / Position 1)

 

 

25) The connector is now ready for hook up. Please refer to the hook up procedure.

 

 

BR PROCEDURE
1) The BR connector is supplied ready terminated with tails.
Simply fit into suitable junction box / equipment as required. To maintain the IP rating of the equipment, a sealing washer should be used (available separately) as shown below.

 

 

2) Terminate the conductors and earth wire inside the junction box / equipment.


3) The connector may also be earthed externally via the crimp with a 4mm² conductor if required.

 

 

4) The connector is now ready for hook up. Please refer to the hook up procedure.

 

HOOK UP PROCEDURE

 

WARNING:
Only the socket insert is allowed to remain energised while de-mated. If being used with bi-directional signals, isolate elswhere before connecting / disconnecting.

 

Before commencing hook up, a visual inspection should be carried out on the cable / connector assembly. The assembly should be checked to ensure that all of the assembly components are tight. If the assembly components have
loosened during transportation / cable installation, they should be retightened in accordance with the relevant assembly instruction sheets without twisting the cable in the connector assembly.

 

1) Remove connector caps.


2) Ensure the connectors are both set to the same keying position colour or numbered (no colour or number for default 12 o’clock position on BR/CR) and are of the same insert type.
It should be noted that colour coded and numbered connector bodies are mutually interchangeable.

 

 

3) Engage the CP connector with the BR / CR connector and align the keyway on the CP connector to the key on the BR / CR connector.

 

 

 

4) Engage the two connectors by screwing the engaging nut clockwise without interruption onto the BR/CR shell. If the threads will not engage, the connectors
are set to different keying positions.

 

 

5) If anti-vibration protection is required, tighten the grub screw on the CP shell.

 

 

6) To disconnect, slacken the tightened grub screw, turn the engaging nut anti-clockwise and remove the connector. Fit the caps.

 

Technical Data

InstrumEx Spec.pdf

InstrumEx Manual 20140403.pdf

InstrumEx BRO 200808XX.pdf

0.Ex Connectors Master Catalogue 20130819.pdf

 

 

 

 

 

내 기술지원 및 구매상담처

CUSTOMER SUCCESS IDK

deric@jadongwha.com

www.tiatip.com

 

 

저작자 표시
신고
Posted by TIATIP

댓글을 달아주세요:: 네티켓은 기본, 스팸은 사절

Hawke Power Connector, PowerEx Termination Hook up Procedure 자료

 

안녕하세요 TIATIP 입니다.

 

오늘 이 시간에는 Hawke Power Connector, PowerEx 시리즈의 Termination Hook up Procedure 관련 자료를 소개합니다.

 

 

Hawke

PowerEx Termination Procedure

 

IMPORTANT NOTE
Hawke International does not recommend the use of their Power Connectors in applications where rigid PVC/SWA/PVC power cabling (typically to BS 6346 standards) is used in portable / semi-portable applications.


In addition, Hawke recommends that barrier type glands are fitted to flexible power and loose filled control cabling entering the connectors to maintain the Exd protection concept and to reduce the potential for core movements within the cable being transferred to the connector’s internal components. 

 

 

 

 

CP / CR PROCEDURE
1) Terminate the cable into the Exd cable gland as per the manufacturer’s instructions. Consider at this stage the relative position of the phases.

 

 

 

2) Cut the conductors to the lengths shown. (For earth conductors which are being terminated to the earth ring (see step 6) but not carried through the contact, cut back X = 100mm for all sizes, see 10 - 13)

 

 

 

3) Strip back the insulation as shown. (For all earth conductors terminated via the internal earth ring, cut back the insulation flush with the gland entry thread, see 10 - 13).

 

 

 

4) Unscrew the rear engaging nut from the CP / CR shell. Remove the rear shell, spacer tube and insert from the CP / CR shell.

 

 

5) a) CONTACT SIZES 50 - 240mm².

Remove the screws from the front of the contacts only and push the crimp lugs out of the insert.

 

 

b) CONTACT SIZES 300 – 630mm².

Remove the screw from the plastic housing and remove the contact from inside.

 

 

 

6) Remove the internal earth ring from the rear shell sub assembly by backing off the 2 grub screws on the flats. If internal earthing is not required, the internal earth ring assembly along with the fixing grub screws should be discarded.

 

 

 

7) Crimp the lugs or contacts onto the conductors

(excluding internal earth wire if being used) using suitable crimp tool. (Hawke recommend Elpress crimp tools).
Contact sizes of 185mm² and larger should be adjacently double crimped as shown.

 


 

8) Feed the conductors through the rear shell assembly and screw this onto the cable gland entry thread ensuring the sealing washer is present.

 

 

 

9) Measure the distance from the front of the rear shell to the end of the crimp lug (50 – 240mm²) or contact (300 - 630mm²). It should be as shown. If not, remove the rear shell and add or remove the spacer washers supplied to get the required length. At least 1 washer must be present to maintain IP rating.

 

 

 

Internal earth procedure (skip to step 13 if not used or you have single phase connector).


10) Slide the internal earth ring down over the conductors with the lug going over the bare earth wire.

 

 

 

 

11) Position the internal earth ring inside the rear shell and tighten the grub screws into the groove on the earth ring. Excessive force could distort rear shell.

 

 

 

 

 

12) Tighten the 2 grub screws on the internal earth lug into the earth conductor as tight as possible so that the earth wire is sufficiently clamped. If earth is to be carried through to a contact, crimp contact prior to tightening grub screws.

 

 

 

 

13) Slide the spacer tube over the conductors and onto the rear shell.

 

 

 

 

14) a) CONTACT SIZES 50 - 240mm².
Push the insert assembly fully onto the crimp lugs. The insert should push inside the spacer tube. Refit the 4 screws into the ends of the contacts. Ensure these are fully tightened.

 

 

 

 

b) CONTACT SIZES 300 – 630mm².
Push the rear retainer over the contact. Place the split tube around the contact. Slide the front contact retainer over the contact and split tube. Slide the rear contact retainer over the rear of the contact and tighten the screw fully.

 

 

 

15) Slide the CP / CR shell over the insert and line the yellow dot on the insert up with the required keying position 1 to 5 marked on the CP / CR shell.

 

 

16) Screw the rear engaging nut fully onto the CP / CR shell.
Measure the distance between the front of the rear engaging nut to the back of the engaging nut which should be no greater than the distance shown.

 

 

 

17) Tighten down the 2 grub screws on the rear engaging nut.

 

 

 

18) Terminate the equipotential external earth to the ring terminal crimp provided if applicable. Remove the button head screw, spring washer and crimp from the rear engaging nut. Crimp the external earth wire into the crimp and reassemble.

 

 

 

19) Refit the protective or flameproof cap if applicable.

 

 

 

20) The connector is now ready for installation. Please refer to the hook up procedure.

 

 

 

HOOK UP PROCEDURE
Before commencing hook up, a visual inspection should be carried out on the cable / gland / connector assembly. The assembly should be checked to ensure that all of the assembly components are tight. If the assembly  components have loosened during transportation/cable installation, they should be retightened in accordance with the relevant assembly instruction sheets without twisting the cable in the cable gland/connector assembly. No hazardous gases should be present.

 

1) Turn off the power to the connectors.


2) Ensure the connectors are both set to the same keying position number, are of the same insert type and phase orientation.

 

 

3) Engage the CP connector with the BR / CR connector and align the key on the CP connector to the keyway on the BR / CR connector.

 

 

4) Engage the two connectors by screwing the engaging nut clockwise onto the BR/CR shell. If the engaging nut will not screw on more than half a turn, then the connectors are set to different keying positions.

 

 

5) Fully tighten the engaging nut with strap wrench if necessary and then tighten the grub screw on the engaging nut.

 

 

 

6) To disconnect, turn off the power (no hazardous gases should be present), slacken the tightened grub screw, turn the engaging nut anti-clockwise and remove the connector. If power is to be put through the connectors whilst demated, then a flameproof cap (available separately) must be fitted.

 

 

Technical Data

PowerEx Spec.pdf

PowerEx Manual 20070619.pdf

0.Ex Connectors Master Catalogue 20130819.pdf

 

 

 

내 기술지원 및 구매상담처

CUSTOMER SUCCESS IDK

deric@jadongwha.com

www.tiatip.com

 

 

저작자 표시
신고
Posted by TIATIP

댓글을 달아주세요:: 네티켓은 기본, 스팸은 사절

Hawke Exd Connector, PowerEx 기술사양

 

안녕하세요 TIATIP 입니다.

 

오늘 이 시간에는 호크 방폭커넥터 제품군 가운데, Power 연결 애플리케이션에 적합한 Hawke PowerEx 시리즈를 살펴보도록 하겠습니다.

HAWKE

Range For Harsh and Hazardous Locations

Hazardous Area Connector

PowerEx

IECEx/ATEX Certificate 

 

Overview

The PowerEx range of connectors have been designed specifically for the extremely demanding requirements of higher power applications.

 

 

 

Inserts are available with 1 to 4 contacts with a conductor acceptance range of between 50mm2 and 630mm2 operating up to 780A and 750V as standard. Other voltages available on special request.

 

 

Tamb: -40°C to +60°C.

II2 GD Exd IIC ExtD T85.

IP66, 67

DTS01 deluge protected.

 

 

 

 

Hawke Exd Connector Range For Harsh and Hazardous Locations, PowerEx

 

Technical Data

PowerEx Spec.pdf

PowerEx Manual 20070619.pdf

 

 

 

 

내 기술지원 및 구매상담처

CUSTOMER SUCCESS IDK

deric@jadongwha.com

www.tiatip.com

 

저작자 표시
신고
Posted by TIATIP

댓글을 달아주세요:: 네티켓은 기본, 스팸은 사절

T&B, Type A-Non-Metallic Liquidtight Conduit & Fittings, 3721-TB

 

안녕하세요 TIATIP 입니다.

 

오늘 이 시간에는 Non-Metallic Liquidtight Conduit & Fittings, 3721-TB 에 대해 살펴보도록 하겠습니다.

 

Thomas&Betts

TnB, T&B Catalog Number : 3721-TB

 

 

 

Description :

1/2 in. steel Type A liquidtight connector with insulated throat and sealing ring with steel retainer.

 

 

 

 

Features :

Steel or malleable iron construction with nylon-insulated throat.

Santoprene sealing gasket includes Type 316 stainless steel retaining ring.

NPT hub threads seal in female threads.

Offers high mechanical pull-out strength.

Supplied with sealing ring and steel locknut.

Available in straight, 45 degree and 90 degree in hub sizes from 3/8 in. to 2 in..

 

 

 

 

Application :

Provides a positive seal against water, oil and dust

 

 

 

 

 

Technical Data :

Type A Liquidtight Connectors Conduit.pdf

Type A Liquidtight Flexible Metal Conduit Connectors.pdf

TnB Sales Drawings WSD000106.pdf

Guide to Nonmetallic Conduit Applications.pdf

 

 

 

 

 

 

 

 

내 기술지원 및 구매상담처

CUSTOMER SUCCESS IDK

deric@jadongwha.com

www.tiatip.com

 

저작자 표시
신고
Posted by TIATIP

댓글을 달아주세요:: 네티켓은 기본, 스팸은 사절

T&B,TnB,Ty-Rap, Cable Tie TY27MFR 사양소개

 

안녕하세요 TIATIP 입니다.

 

오늘 이 시간에는 Thomas&Betts(T&B,TnB),Ty-Rap Cable Tie TY27MFR 사양에 대해 살펴보도록 하겠습니다. 

 

 

 

 

Cable Tie Standard

T&B Catalog Number : TY27MFR

 

 

 

 

Description

Cable Tie 120lb 13" Flame Retardant White with Stainless Steel Locking Device

 

  

 

Features

Low profile head is designed to prevent snags on uneven surfaces and easier to pull through bulkheads. Non-magnetic stainless steel locking device insures both maximum strength and the right tightness every time

 

Because there are no notches, Ty-Rap ties provide an infinite number of locking positions while fastening the tie at the precise bundle diameter needed

 

 

The No-Slip Tail provides easy grip during tensioning. Ty-Rap ties feature a unique friction surface designed to reduce slippage during installation

 

Smooth, notchless body reduces stress concentration points under tension, making the tie stronger and lower profile than notched body ties. Ribbed and Stippled body grips the bundle and prevents slippage. Rounded edges protect insulation, preventing sharp edges from damaging cables

 

 

 

 

Technical Data

CAT01.12 TyRap HighPerformance Cable Ties Tools Accessories.pdf

 

 

 

 

 

 

  

내 기술지원 및 구매상담처

CUSTOMER SUCCESS IDK

deric@jadongwha.com

www.tiatip.com

 

 

 

 

저작자 표시
신고
Posted by TIATIP

댓글을 달아주세요:: 네티켓은 기본, 스팸은 사절

Hawke Thread Conversion Solutions Fixed Elbows 496(F to F) Series 기술사양 소개 (UPD20140531)

 

안녕하세요 TIATIP 입니다.

 

오늘 이 시간에는 2014년 05월 31일자로 업데이트된 호크 케이블글랜드의 Thread Conversion Solutions 자료 가운데, 496시리즈 (F to F) 90˚ Fixed Elbow에 대해 살펴보겠습니다.

 

 

 

HAWKE International

A Division of Hubbell Incorporated

90˚ Fixed Elbow

496 Series

Hazardous Area

Flameproof Exd

Increased Safety Exe

Dust Protection Extb

Dual Certified ATEX/IECEx

 

 

 

  

 

Certification Details

Flameproof Exd IIC Gb, Increased Safety Exe IIC Gb and Dust Extb IIIC Db II 2GD.

• Certifi cate No's: Baseefa14ATEX0014U and IECEx BAS 14.0002U.

• Operating Temperature Range -60°C to +200°C.

• Group II and III.

 

 

 

 

 

 

General Information

• Manufactured in Brass, Nickel Plated Brass, Steel, Nickel Plated Steel and Stainless Steel.

• M20 to M75 as standard.

• Other parallel male thread options available on request, including BSPP, PG, ET and NPSM.

• NPT female threads can also be supplied in sizes ranging from ½ " to 3".

• Suitable for use in Zone 1, Zone 2, Zone 21, Zone 22 and mining applications.

• Construction and Test Standards: IEC/EN 60079-0, IEC/EN 60079-1 IEC/EN 60079-7 and IEC/EN 60079-31.

• Ingress Protection: IP66.

• Assembly Instruction Sheet: AI 430.

 

 

 

 

 

Note:

Diff erent thread sizes and types are permitted at each end of the elbow, a step of one thread size is permitted between the two threads. Where diff erent thread types/sizes are supplied, the overall dimensions may increase in size.

 

 

 

 

 

Ordering Example :

496/M32 Female x M32 Female 1.5mm Brass Nickel Plated

 


Technical Data :

496 Spec IDK 20140531.pdf

494 IDK Spec 20140531.pdf

495 IDK Spec 20140531.pdf

2.Hawke Accessories 2013 IDK.pdf

 

 

 

 

  

내 기술지원 및 구매상담처

CUSTOMER SUCCESS IDK

deric@jadongwha.com

www.tiatip.com

 

 

저작자 표시
신고
Posted by TIATIP

댓글을 달아주세요:: 네티켓은 기본, 스팸은 사절

Hawke Thread Conversion Solutions Fixed Elbows 495 (M to M) Series 기술사양 소개 (UPD20140531)

 

안녕하세요 TIATIP 입니다.

 

오늘 이 시간에는 2014년 05월 31일자로 업데이트된 호크 케이블글랜드의 Thread Conversion Solutions 자료 가운데, 495시리즈 (M to M) 90˚ Fixed Elbow에 대해 살펴보겠습니다.

 

 

 

 

HAWKE International

A Division of Hubbell Incorporated

90˚ Fixed Elbow

495 Series

Hazardous Area

Flameproof Exd

Increased Safety Exe

Dust Protection Extb

Dual Certified ATEX/IECEx

 

 

 

 

 

Certification Details

• Flameproof Exd IIC Gb, Increased Safety Exe IIC Gb and
Dust Extb IIIC Db II 2GD.

• Certifi cate No's: Baseefa14ATEX0014U and IECEx BAS 14.0002U.

• Operating Temperature Range -60°C to +200°C.

• Group II and III.

 

 

 

General Information

• Manufactured in Brass, Nickel Plated Brass, Steel, Nickel Plated Steel and Stainless Steel.

• M20 to M75 as standard.

• Other thread options available on request, including BSPP, PG, ET and NPSM. NPT threads are not permitted.

• Suitable for use in Zone 1, Zone 2, Zone 21, Zone 22 and mining applications.

• Construction and Test Standards: IEC/EN 60079-0, IEC/EN 60079-1 IEC/EN 60079-7 and IEC/EN 60079-31.

• Ingress Protection: IP66.

• Assembly Instruction Sheet: AI 429.

 

 

Note:

Diff erent thread sizes and types are permitted at each end of the elbow, a step of one thread size is permitted between the two threads. Where diff erent thread types/sizes are supplied, the overall dimensions may increase in size.

 

 

 

 

Ordering Example :

495/M32 Male x M32 Male 1.5mm Brass Nickel Plated

 

 

 


Technical Data :

495 IDK Spec 20140531.pdf

496 Spec IDK 20140531.pdf

494 IDK Spec 20140531.pdf

2.Hawke Accessories 2013 IDK.pdf

 

 

 

 

  

내 기술지원 및 구매상담처

CUSTOMER SUCCESS IDK

deric@jadongwha.com

www.tiatip.com

 

 

저작자 표시
신고
Posted by TIATIP

댓글을 달아주세요:: 네티켓은 기본, 스팸은 사절

Hawke Thread Conversion Solutions Fixed Elbows 494 (M to F) Series 기술사양 소개 (UPD20140531)

 

안녕하세요 TIATIP 입니다.

 

오늘 이 시간에는 2014년 05월 31일자로 업데이트된 호크 케이블글랜드의 Thread Conversion Solutions 자료 가운데, 494시리즈 (M to F) 90˚ Fixed Elbow에 대해 살펴보겠습니다.

 

 

HAWKE International

A Division of Hubbell Incorporated

90˚ Fixed Elbow

494 Series

Hazardous Area

Flameproof Exd

Increased Safety Exe

Dust Protection Extb

Dual Certified ATEX/IECEx

 

 

 

Certification Details

• Flameproof Exd IIC Gb, Increased Safety Exe IIC Gb and Dust Extb IIIC Db II 2GD.

• Certifi cate No's: Baseefa14ATEX0014U and IECEx BAS 14.0002U.

• Operating Temperature Range -60°C to +200°C. • Group II and III.

 

 

 

General Information

 • Manufactured in Brass, Nickel Plated Brass, Steel, Nickel Plated Steel and Stainless Steel.

• M20 to M75 as standard.

• Other parallel male thread options available on request, including BSPP, PG, ET and NPSM.

• NPT female threads can also be supplied in sizes ranging from ½ " to 3".

• NPT threads are not permitted on the Male threaded selection.

• Suitable for use in Zone 1, Zone 2, Zone 21, Zone 22 and mining applications.

• Construction and Test Standards: IEC/EN 60079-0, IEC/EN 60079-1 IEC/EN 60079-7 and IEC/EN 60079-31.

• Ingress Protection: IP66.

• Assembly Instruction Sheet: AI 428

 

 

 

 

Note:

Diff erent thread sizes and types are permitted at each end of the elbow, a step of one thread size is permitted between the two threads. Where diff erent thread types/sizes are supplied, the overall dimensions may increase in size.

 

 

Ordering Example :

494/M32 Male x M32 Female 1.5mm Brass Nickel Plated

 

 

 


Technical Data :

494 IDK Spec 20140531.pdf

495 IDK Spec 20140531.pdf

496 Spec IDK 20140531.pdf

2.Hawke Accessories 2013 IDK.pdf

 

 

 

 

 

  

내 기술지원 및 구매상담처

CUSTOMER SUCCESS IDK

deric@jadongwha.com

www.tiatip.com

 

 

저작자 표시
신고
Posted by TIATIP

댓글을 달아주세요:: 네티켓은 기본, 스팸은 사절

Hawke Cable Gland 321/R Series 기술사양 소개 (UPD20140611)

 

안녕하세요 TIATIP 입니다.

 

오늘 이 시간에는 2014년 06월 11일자로 업데이트된 호크 케이블글랜드 321/R 시리즈에 대한 사양에 대해 살펴보겠습니다.

 

 

 

 

HAWKE International

A Division of Hubbell Incorporated

Cable Glands

321/R Series

Hazardous Area

Increased Safety Exe

Class-Zones-Divisions

Certified ATEX/IECEx/cCSAus

 

 

 

 

Application
The 321/R cable gland provides a seal and cable clamp on the
outer cable sheath and is intended for use on non-armoured
elastomer and plastic insulated cables. The cable gland certifi ed
Exe and is suitable for installation in Zone 1 (21) and Zone 2 (22)
hazardous areas.

 

 

 

 

Technical Data

 

ATEX/IECEx
- Increased Safety Exe IIC Gb and Dust Extb IIIC Db II 2 GD.
- Certifi cate No’s: Baseefa06ATEX0059X and IECEx BAS 06.0016X.
- Suitable for use in Zone 1, Zone 2, Zone 21, Zone 22.
- Construction and Test Standards: IEC/EN 60079-0, IEC/EN 60079-7 and IEC/EN 60079-31.
- Ingress Protection: IP66, IP67 and IP 68 (30 metres for 7 days) to IEC/EN 60529 and NEMA 4X.
- Deluge Protection to DTS01.
- Operating Temperature Range: -60°C to +100°C.
- Assembly Instruction Sheet: AI 452.

 

cCSAus
- Increased Safety AExe IIC and Dust AExtD Zone 21.
- Explosion-proof Class 1 Division 2, Class II Division 2 Groups EFG, Class III.
- Certifi cate No’s: CSA1205533 for Marine Shipboard Cable.
- Construction and Test Standards: UL 60079-0, UL 60079-7, ISA 60079-31.
- CSA 22.2 No: 60079-0, CSA 22.2 No: 60079-7, CSA 22.2 No: 60079-31, UL 2225

 

 

 

 

Features
• When used in Increased Safety applications, this cable gland may be used with braided cable where the braid and the outer sheath pass into the enclosure. The braid must then be suitably terminated inside the enclosure.
Note: Braided cable is classed as unarmoured cable in the EN/IEC 60079 series standards for Exe applications.

• Manufactured in Brass (standard), Nickel Plated Brass, 316 Stainless Steel or Aluminium.

• Brass NPT entries are nickel plated as standard.

• Cable clamp provides required clamp and cleat function

 

Ordering Information
Format for ordering is as follows:
Certifi cation required i.e. ATEX / IECEx
Material & Finish i.e. Brass Nickel Plated
Alternative Seal (S), add suffix S to ordering information.

 

Example

321/R/C/M32/S/Nickel Plated Brass ATEX Certified

 

 

 

 

 

 

321R IDK Spec 20130129.pdf

321R IDK Spec 20140611.pdf

1.Hawke Accessories 2012 IDK.pdf

2.Hawke Accessories 2013 IDK.pdf

 

 

 

 

 

  

내 기술지원 및 구매상담처

CUSTOMER SUCCESS IDK

deric@jadongwha.com

www.tiatip.com

 

 

 

저작자 표시
신고
Posted by TIATIP

댓글을 달아주세요:: 네티켓은 기본, 스팸은 사절

Hawke Cable Gland 321 Series 기술사양 소개 (UPD20140611)

 

안녕하세요 TIATIP 입니다.

 

오늘 이 시간에는 2014년 06월 11일자로 업데이트된 호크 케이블글랜드 321 시리즈에 대한 사양에 대해 살펴보겠습니다.

 

 

HAWKE International

A Division of Hubbell Incorporated

Cable Glands

321 Series

Hazardous Area

Increased Safety Exe

Class-Zones-Divisions

Certified ATEX/IECEx/cCSAus

 

 

Application
The 321 cable gland provides a seal on the outer cable sheath and is
intended for use on non-armoured elastomer and plastic insulated
cables. The cable gland certifi ed Exe and is suitable for installation in
Zone 1 (21) and Zone 2 (22) hazardous areas.

 

 

 

 

Technical Data

 

ATEX/IECEx
- Increased Safety Exe IIC Gb and Dust Extb IIIC Db II 2 GD.
- Certifi cate No’s: Baseefa06ATEX0059X and IECEx BAS 06.0016X.
- Suitable for use in Zone 1, Zone 2, Zone 21, Zone 22.
- Construction and Test Standards: IEC/EN 60079-0, IEC/EN 60079-7 and IEC/EN 60079-31.
- Ingress Protection: IP66, IP67 and IP 68 (30 metres for 7 days) to IEC/EN 60529 and NEMA 4X.
- Deluge Protection to DTS01.
- Operating Temperature Range: -60°C to +100°C.
- Assembly Instruction Sheet: AI 451.

 

cCSAus
- Increased Safety AExe IIC and Dust AExtD Zone 21.
- Explosion-proof Class 1 Division 2, Class II Division 2 Groups EFG, Class III.
- Certifi cate No’s: CSA1205533 for Marine Shipboard Cable.
- Construction and Test Standards: UL 60079-0, UL 60079-7, ISA 60079-31.
- CSA 22.2 No: 60079-0, CSA 22.2 No: 60079-7, CSA 22.2 No: 60079-31, UL 2225

 

 

 

Features
• When used in Increased Safety applications, this cable gland may be used with braided cable where the braid and the outer sheath pass into the enclosure. The braid must then be suitably terminated inside the enclosure.
Note: Braided cable is classed as unarmoured cable in the EN/IEC 60079 series standards for Exe applications.

• Manufactured in Brass (standard), Nickel Plated Brass, 316 Stainless Steel or Aluminium.

• Brass NPT entries are nickel plated as standard.

 

 

Ordering Information
Format for ordering is as follows:
Certifi cation required i.e. ATEX / IECEx
Material & Finish i.e. Brass Nickel Plated
Alternative Seal (S), add suffix S to ordering information.

 

Example

321/C/M32/S/Nickel Plated Brass ATEX Certified

 

 

 

 

321 IDK Spec 20140611.pdf

321 IDK Spec 20110609.pdf

2.Hawke Accessories 2013 IDK.pdf

1.Hawke Accessories 2012 IDK.pdf

 

 

 

 

  

내 기술지원 및 구매상담처

CUSTOMER SUCCESS IDK

deric@jadongwha.com

www.tiatip.com

 

 

 

저작자 표시
신고
Posted by TIATIP

댓글을 달아주세요:: 네티켓은 기본, 스팸은 사절


BLOG main image
by TIATIP

카테고리

TI Story (948)N
TIA (92)
TIP (194)
TIEx (592)N
TIS (36)
TIO (23)
TiNoTe (10)
The OtherS (1)