IECEx Scheme

2013.05.28 18:25

IECEx Scheme

안녕하세요 TIATIP 입니다.


Hawke(호크)의 IECEx Scheme에 대해 조금 살펴보겠습니다.


The objective of the IECEx Scheme is to facilitate international trade in electrical equipment intended for use in potentially explosive atmospheres by eliminating the need for multiple national certification.


The IECEx Scheme provides a means for manufacturers to obtain Certificates of Conformity that will be accepted at national level in all participating countries. A Certificate of Conformity may be obtained from any certification body accepted into the scheme. The objective of the IECEx Scheme is world-wide acceptance of one standard, one certificate, and one mark.


For the IEC scheme to achieve its objective, every applicable national standard will need to be identical to the corresponding IEC standard. A transition period will be necessary to allow time for participating IECEx Scheme countries to align their national standards with the IEC standards and work towards national acceptance of IECEx Certificates of Conformity and the IECEx mark.







국내 기술지원 및 상담구매처




'TiNoTe' 카테고리의 다른 글

Wiring Systems NEC  (0) 2013.05.28
North American Hazardous (Classified) Locations  (0) 2013.05.28
Material Safety Data Sheets  (0) 2013.05.28
IECEx Scheme  (0) 2013.05.28
CENELEC and IEC Degree of Protection, IP Code  (0) 2013.05.28
방폭에 대한 이해 - 기초개념 편  (5) 2013.05.05

댓글을 달아주세요:: 네티켓은 기본, 스팸은 사절

Hawke 321 Cable Gland


안녕하세요?  TIATIP 입니다.


오늘은 Hawke 호크케이블그랜드 가운데 Increased Safety, Ex'e' 타입의 애플리케이션에 해당하는 제품인 Hawke 321 케이블그랜드를 소개합니다.






Cable Glands
Hazardous Area
Increased Safety Exe
Dual Certified ATEX / IECEx

Hawke 321 Cable Gland






The 321 Cable Gland is only available from Hawke nternational distributor Stahl-Syberg.



 Hawke 321 Cable Gland




The 321 cable gland provides a seal on the outer cable sheath and is intended for use on non-armoured elastomer and plastic insulated cables. The cable gland certifi ed Exe and is suitable for installation in Zone 1 (21) and Zone 2 (22) hazardous areas.




• When used in Increased Safety applications, this cable gland may be used

   with braided cable where the braid and the outer sheath pass into the


• The braid must then be suitably terminated inside the enclosure.
   Note: Braided cable is classed as unarmoured cable in the EN/IEC 60079

   series standards for Exe applications.

• Manufactured in Brass (standard), Nickel Plated Brass, 316 Stainless Steel or


• Brass NPT entries are nickel plated as standard.



Hawke Accessories for Cable Glands and Junction Boxes/Enclosures





Technical Data

• Increased Safety Exe II 2 GD ExtD A21.

• Certifi cate No’s: Baseefa06ATEX0059X and IECEx BAS 06.0016X.

• Suitable for use in Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA,

   IIB and IIC.

• Construction and Test Standards: IEC/EN 60079-0, IEC/EN 60079-7, IEC/EN

  61241-0 and IEC/EN 61241-1.

• Ingress Protection: IP66, IP67 and IP 68 (30 metres for 7 days) to IEC/EN

  60529 and NEMA 4X.

• Deluge Protection to DTS01.

• Operating Temperature Range: -60°C to +100°C.

• Assembly Instruction Sheet: AI 307.

• Alternative certifi cation options available:

















Hawke Thread Conversion Solutions for Cable Glands and Junction Boxes/Enclosures




보다 자세한 사양(Technical Specification)은 다음의 세가지 첨부파일을 참고하시기 바랍니다.



321 IDK Spec 20110609.pdf

321 IDK Spec 20140611.pdf

321 Assembly 3.pdf

1.Cable Glands-Group ll.pdf

2.Hawke Accessories 2013 IDK.pdf






내 기술지원 및 구매상담처



'TIEx > HAWKE' 카테고리의 다른 글

Hawke 153RAC Cable Gland의 주요특징 및 기술사양  (0) 2013.01.04
Hawke Cable Gland 악세서리모음  (0) 2012.12.18
Hawke 321 Cable Gland  (0) 2012.12.18
Hawke SB474 Cable Gland  (0) 2012.12.18
Hawke PSG553RAC Cable Gland  (0) 2012.12.18
Hawke ICG653Universal/L Cable Gland  (0) 2012.12.18

댓글을 달아주세요:: 네티켓은 기본, 스팸은 사절

BLOG main image
공장자동화 공정자동화 오토메이션 전장 계장 통합자동화 통합전기전력 by TIATIP


TI Story (968)N
TIA (98)
TIP (193)
TIEx (607)N
TIS (35)
TiNoTe (10)
TIO (23)
The OtherS (1)