호크 Hawke 755 Cable Gland/Connector 기술사양
안녕하세요 TIATIP 입니다.
오늘은 호크 Hawke American Series가운데, Class 1 Division 2, TC- ITC, Armoured, UL-ATEX Approved 특성의 755 Cable Gland/Connector를 살펴보겠습니다.
Hawke
Cable Gland/Connector
755 Cable Gland/Connector
American Series
Explosion Proof / IECEx and ATEX Approved Flameproof Exd / Increased Safety Exe and Restricted Breathing ExnR
Application
Outdoor or indoor use.
For use with armoured jacketed cable, as permitted by the NEC.
Features
Provides a barrier seal between the individual insulated conductors within the cable and prevents entry of the products of an explosion into the cable.
Assembly of the cable gland/connector compresses and distributes the compound evenly to create a barrier seal at the point of entry into the enclosure.
Provides an outer deluge seal to prevent moisture ingress to the cable armour and enclosure. Deluge seal is coloured red to indicate hazardous locations product.
Provides a cable retention and low smoke and fume, zero halogen seal onto the cables outer jacket.
Materials & Finishes
The 755 cable gland/connector is manufactured in Brass (standard), Nickel Plated Brass, 316 Stainless Steel or Aluminum. Brass NPT entries are nickel plated as standard.
Technical Data
1.UL Listing No: E84940.
2.Suitable for use in: Class 1, Division 2, Gas Groups A, B , C and D.
Class 1, Zone 2, Gas Groups IIA, IIB and IIC.
AExd IIC and AExe II Class 1, Zone 2.
3.Flameproof Exd, Increased Safety Exe II2 GD and Restricted Breathing ExnR II 3G
4.Certificate No's Sira 06ATEX1295X and IECEx Sir 06.0082X.
5.Suitable for use in: Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC.
6.Construction and Test Standards: UL 2225, IEC/EN 60079-0, IEC/EN 60079-1, IEC/EN 60079-7, IEC/EN 60079-15, IEC/EN 61241-0 and IEC/EN 61241-1.
7.Ingress Protection:
IP66, IP67 and IP68 (30 metres for 7 days) to IEC/EN 60529 and NEMA 4X.
8.Deluge Protection to: DTS01
9.Operating Temperature Range: -50°C to +60°C (UL) and -60°C to +80°C (ATEX / IECEx)
10.Note: 755 cable glands are supplied dual ATEX/UL marked as standard.
11.Assembly Instruction Sheet: AI 319 (UL). AI 382 (ATEX / IECEx).
1.Cable Glands-American Series NEC,IEC.pdf
2.Hawke Accessories 2013 IDK.pdf
Installation Guide
Hawke 755 Cable Gland/Connector
Hawke Ordering Format [Gland Type/Size/Thread]
Example : 755/C/1"NPT
국내 기술지원 및 구매상담처
CUSTOMER SUCCESS IDK
'TIEx > HAWKE' 카테고리의 다른 글
호크 Hawke Enclosures PL612 Series 기술사양 (0) | 2014.03.30 |
---|---|
호크 Hawke American Series NEC/IEC 라인업소개 (0) | 2014.03.25 |
호크 Hawke 753 Cable Gland/Connector 기술사양 (0) | 2014.03.25 |
호크 Hawke 713 Cable Gland/Connector 기술사양 (0) | 2014.03.25 |
호크 Hawke 711 Cable Gland/Connector 기술사양 (0) | 2014.03.25 |